Panasonic PT-RZ770 / PT-RW730 / PT-RZ660 / PT-RW620 (serv.man2) Service Manual ▷ View online

INF-17
SECTION 1 SERVICE INFORMATION
< RZ770/RW730/RZ660/RW620 >
 (3)   [EMULATE] is added in sub menu [RS-232C].
    -  The following choices will be added. (Default setting : DEFAULT)
      MODE_HI / MODE_NE / MODE_EP / MODE_SA / MODE_SH / MODE_MI / MODE_SO / MODE_CH / OTHER
 (4) The following items are added to the sub menu [STATUS].
  1) Page 2
    - VERTICAL TILT 
Vertical angle
    - HORIZONTAL TILT 
 Horizontal angle
 
  
  2) Page 3
    - DIGITAL LINK VERSION  
Digital LINK firmware version
    - FPGA VERSION 
 
 FPGA firmware version (FPGA1/FPGA2)
    - FM VERSION  
 
Formatter firmware version
    - LD DRIVER VERSION   
LD Driver firmware version (LD1/LD2)
    - LD SUB VERSION 
 
LD Sub firmware version
    - EMULATE 
 
Status of EMULATE setting
      - VERSION 
 
EMULATE version
 
INF-18
SECTION 1 SERVICE INFORMATION
< RZ770/RW730/RZ660/RW620 >
  3) Page 5
    - MAIN VER. 
 
Main microprocessor firmware version
    - FPGA VER. 
 
 FPGA firmware version (FPGA1/FPGA2)
    - BMP VER. 
 
Bitmap data version
    - ENG VER. ~ CC VER.   
 Version of the each font data 
        
 
(English/Russian/Korean/Chinese/
        
 
 Japanese/Closed caption)
  4) page 6
    - TEMP (
℃) 
 (IN) Intake air / (OPT) Optical module
        
(OUT) Exhaust air / (LD1) LD1 temperature
        
(LD2) LD2 temperature
    - FAN MODE 
Fan control mode [TYPE A - TYPE J]
    - atm 
Atmospheric pressure sensor value [hPa]
    - RADIATOR1
    - RADIATOR2
    - RADIATOR3
    - DMD
    - PW1 *1
    - PW2 *1
    - POWER 
Status of each fan [rpm]
    - DRIVER 
  *1:RZ660 and RW620 displays a dummy value.
    - EXHAUST1
    - EXHAUST2
    - EXHAUST3
    - PUMP1
    - PUMP1
  5) page 7
    - Luminance sensor detected value (simplified calculation value)
      R.SEG 
Red segment : Y / x / y
      G.SEG 
Green segment : Y / x / y
      B.SEG 
Blue segment : Y / x / y
      Y.SEG 
Yellow segment : Y / x / y
      [Note] •Different from the value measured by a illuminance meter.
INF-19
SECTION 1 SERVICE INFORMATION
< RZ770/RW730/RZ660/RW620 >
  6) page 8
    - ON COUNT 
Turn on times of each LD unit
    - RUNTIME 
Runtime of each LD unit
  7) page 9
    - LD1 STATUS 
Status of each unit of LD1 (0 : OFF / 1 : ON)
    - LD2 STATUS 
Status of each unit of LD2 (0 : OFF / 1 : ON)
  8) page 10
      • Displays SDI signal information (No signal is displayed with "---").
    - MODE 
Mode (NO SIGNAL/SD-SDI/HD-SDI/3G-SDI)
    - TRANSPORT 
Conversion method
        
(PROGRESSIVE/INTERLACED)
    - PICTURE 
Picture information
        
(PROGRESSIVE/INTERLACED)
    - RATE 
Rate information
        
(23.98/24.00/25.00/29.97/30.00/50.00/59.94/
        
60.00)
    - SAMPLING 
Sampling information
        
(4:2:2(YPBPR)/4:2:2(YCBCR)/4:4:4(YPBPR)/
        
4:4:4/(YCBCR)/4:4:4(RGB)/4:4:4:4(YPBPR+A)/
        
4:4:4:4(RGB+A)/4:4:4(XYZ))
    - BIT DEPTH 
Bit depth (8bit/10bit/12bit)
INF-20
SECTION 1 SERVICE INFORMATION
< RZ770/RW730/RZ660/RW620 >
  9) page 11 - 12
    - ON/OFF history log of LD1 and LD2
 4. [TEST PATTERN] menu
  • The following test patterns are added.
 5. [NETWORK] menu
  • [CHANNEL A - D] information is added to [SIGNAL QUALITY] of sub menu [DIGITAL LINK STATUS].
- Inverted checker
- Red
- Magenta
- Checker
- Yellow
- Blue
- Cyan
- Green
- CW index adjustment
- Convergence