Panasonic PT-RZ670 / PT-RW630 (serv.man4) Service Manual / Other ▷ View online
SECTION 2 DISASSEMBLY PROCEDURES
< RZ670/RW630 >
4. Unscrew 7pcs the remove the top lid of analysis block-2.
5. Unscrew 2pcs then remove the fan for phosphor wheel-2.
6. Unscrew 3pcs the remove Phosphor wheel 2 holder.
[ Caution ]
・Take care not let phosphor wheel touch on case whi;le removing.
・Do not touch on the phosphor surface of phosphor wheel.
・Do not touch on the phosphor surface of phosphor wheel.
Lid og analysis block-2
Fan for phosphor wheel 2
Phosphor wheel 2 holder
1
6
2
3
DIS-17
SECTION 2 DISASSEMBLY PROCEDURES
< RZ670/RW630 >
7. Unscrew the 3 screws and remove the Phosphor wheel.
(Torque:20±2 N・cm)
8. Unscrew the 3 screws and remove the Lens cover.
9. Unscrew the 6 screws and remove the Optical block (DMD block,Trim wheel cover, Rod case).
Phosphor Wheel
Lens cover
Optical block
3
3
6
DIS-18
SECTION 2 DISASSEMBLY PROCEDURES
< RZ670/RW630 >
10. Unscrew the 4 screws and remove the Lighting block 1.
11. Remove phosphor wheel 1 by same method with phosphor wheel removing process.
Lighting block 1
4
DIS-19
SECTION 2 DISASSEMBLY PROCEDURES
< RZ670/RW630 >
10. Unscrew the 4 screws and remove the Lighting block 1.
11. Remove phosphor wheel 1 by same method with phosphor wheel removing process.
Lighting block 1
4
DIS-19