ADJ-16
SECTION 3 ADJUSTMENTS
< RQ22K >
3. Select the model number of the projector.
4. Select [Setting] of [Option] menu, then select connection method and enter the setting information of the projector.
  
 
   • Select [SERIAL] and set up the Serial Port, Baudrate and Parity of the PC.
 
   
 
 
   • Select [LAN] and set up the IP address, Username, Password and Command Port of the projector.
5. The status and runtime of each LD unit will be displayed by clicking the [Get Information] button.
LAN terminal connection
Serial terminal connection
Items
Default value
SERIAL
Port
Baud Rate
9600bps
Parity
None
LAN
IP Address
192.168.0.8
Username
dispadmin
Password
@Panasonic
Command Port
1024
•  If the Username and Password has been changed, please select serial terminal connection.
When the open failure occurred, the text characters 
becomes red. In addition, "NG" is displayed on sta-
tus.
• Example of display when open failure occurs on LD 1-3
ADJ-17
SECTION 3 ADJUSTMENTS
< RQ22K >
 [Reference] All LD units location
6. Click the [Reset] button corresponding to the replaced LD unit No.
 7. If the LD unit number to be reset in the confirmation window is correct, click the [OK] button.
LD1-3
LD1-2
LD1-1
LD2-3
LD2-2
LD2-1
LD1-6
LD1-5
LD1-4
LD2-6
LD2-5
LD2-4
Display example of LD1-3 reset
ADJ-18
SECTION 3 ADJUSTMENTS
< RQ22K >
8. When the reset completion window is displayed, click the [OK] button.
    Confirm that the runtime of LD unit is "0h" and status is "OK".
[Display example]   The open failure occurs on LD1-3
1.10. LD unit status reset
f
 The error information is stored in the memory if the projector turn on in the state of disconnecting of LD unit connectors.
   In this case, to clear the error status by using the LDResetTool. (Runtime is not reset.)
1.  Start up service software [LDRestTool.exe] with the same procedure of "1. 9. LD unit runtime reset", and click the [Get 
Information] button to display the each LD unit status.
2. Click the [LD Status Reset] button and when the confirmation window is displayed, and then click the [OK] button.
Display example of LD1-3 reset
•   After completing the reset, turn off the main power, turn on the power again, and check that runtime with 
the [STATUS] screen.
ADJ-19
SECTION 3 ADJUSTMENTS
< RQ22K >
3. Completion window is displayed, and click the [OK] button. Confirm the status is "OK".
•   After completing the reset, turn off the main power, turn on the power again, and check that LD status with 
the [STATUS] screen.
1.11. Shutter counter reset
f
 When replacing the mechanical shutter, initialize the shutter opening/closing count.
1.  Enter the service mode, and select sub menu [INITIALIZE] of [PROJECTOR SETUP] menu.
2. Input the security password and press the [ENTER] button.
3. Press [ a ][ s ] button to select [SHUTTER COUNTER] and press the [ENTER] button.
4. A confirmation window is displayed, select [OK] and press the [ENTER] button.
5. Make sure that the shutter counter on self check screen is "0".
SECURITY PASSWORD
INITIALIZE
ALL USER DATA
REGISTERED SIGNAL
NETWORK/E-MAIL
LOGO IMAGE
UNIFORMITY
MENU SELECT
EXECUTE
ENTER
SHUTTER COUNTER
INITIALIZE SHUTTER COUNTER ?
OK
CANCEL
EXECUTE
CHANGE
ENTER
Page of 127