SECTION 2 DISASSEMBLY PROCEDURES
< RQ22K >
4. 1) Unscrew 1 screw-E and remove the earth lead.
    2) Loosen 3 screws-F and remove the color prism1, 2 fan block.
E
Prism1, 2 fan block
F
F
F
E
F
5. Unscrew 2 screws-G and 2 screws-H, and remove the color prism3, 4 fan block, lead wire fixing sheet.
G
G
H
Color prism3, 4 fan block
Lead wire fixing sheet
G
H
DIS-33
SECTION 2 DISASSEMBLY PROCEDURES
< RQ22K >
1
2
DMD support metal
6. Unscrew 1 screw-J and 1 screw-K, and remove the DMD support metal.
7. Unscrew 2 screw-L and remove the WOB unit.
 (Pull the block upward on slant.)
J
K
L
J
K
DMD support metal
• When assembling, tighten the screws in numerical order.
Mechanical shutter unit
2
DIS-34
SECTION 2 DISASSEMBLY PROCEDURES
< RQ22K >
8. Unscrew 4 screws-M and 3 screws-N, and remove the DMD block, liquid cooling unit.
M
M
M
M
N
N
N
Liquid cooling unit
DMD block
DMD block fixing screws location
M
L
DIS-35
SECTION 2 DISASSEMBLY PROCEDURES
< RQ22K >
9. Unscrew the screws from each part and separate the DMD block and liquid cooling unit.
    1) Unscrew the pump fixing spring (2 screws x 3 places) and remove the liquid cooling pump part from the DMD block.
    2) Unscrew 3 screws and separate the tank bracket and liquid cooling tank.
2 x3
4
Tank bracket
Liquid cooling tank
• Notes on installing of liquid cooling pump 
  1) Apply the heat dissipation compound evenly to the rear surface of the pumps. 
  2) Do not pinch the lead wire of DMD temperature sensor with the pump for green. 
  3) Do not to fold or twist the liquid cooling tubes.
Heat dissipation compound :
Shin-Etsu Silicone [ G-776 ] grade 0.05g x3
DMD block
Liquid cooling pump
Pump fixing spring
Apply heat dissipation 
compound
Liquid cooling pump
DMD temperature sensor
When a lead wire is passed through this area, 
it is pinched by the pump and disconnected.
Pass the DMD temperature 
sensor lead wire through the 
insulation sheet hole.
Page of 127