INF-35
SECTION 1 SERVICE INFORMATION
< RQ13K >
5. 3. 4. Error cord of system log
Bit
Error code (hex)
Self-test 
indication Details
Probable cause
0
LOW
ER
00000000 00000001
U11
Intake air temperature warning
External temperature is too high. 
Intake ventilation holes are blocked.
1
00000000 00000002
U12
Optical module temperature warning
Mounting of heatsink is abnormal.
Ventilation holes are blocked.
2
00000000 00000004
U13
Exhaust temperature warning
Exhaust ventilation holes are blocked 
Exhaust fan  deterioration
3
00000000 00000008
U14
Optical module low temperature warning
External temperature is too low.
4
00000000 00000010
U21
Intake air temperature error
External temperature is too high.
Intake ventilation holes are blocked.
5
00000000 00000020
U22
Optical module temperature error
Mounting of heatsink is abnormal.
Ventilation holes are blocked.
6
00000000 00000040
U23
Exhaust temperature error
Exhaust ventilation holes are blocked. 
Exhaust fan deterioration.
7
00000000 00000080
U24
Optical module low temperature error
External temperature is too low.
8
00000000 00000100
Not used
9
00000000 00000200
Not used
10
00000000 00000400
Not used
11
00000000 00000800
Not used
12
00000000 00001000
Not used
13
00000000 00002000
Not used
14
00000000 00004000
Not used
15
00000000 00008000
Not used
16
00000000 00010000
Not used
17
00000000 00020000
Not used
18
00000000 00040000
Not used
19
00000000 00080000
Not used
20
00000000 00100000
Not used
21
00000000 00200000
Not used
22
00000000 00400000
Not used
23
00000000 00800000
Not used
24
00000000 01000000
FH0
PW1 error (FM/SUB)
PHOSPHOR WHEEL1 operation is abnormal
25
00000000 02000000
FH1
PW1 error (FPGA)
26
00000000 04000000
FH2
PW2 error (FM/SUB)
PHOSPHOR WHEEL2 operation is abnormal
27
00000000 08000000
FH3
PW2 error (FPGA)
28
00000000 10000000
U81
Low AC voltage warning
AC input voltage is too low (Less than 90V)
29
00000000 20000000
Not used
30
00000000 40000000
U75
Special filter setting
EXTRA OPTION→AIR FILTER [SPECIAL] selected
31
00000000 80000000
F15
Luminance sensor warning
Luminance sensor operation error
32
00000001 00000000 
H11
Intake air temp sensor disconnected
Intake air temp sensor disconnected. Connector (M11/RM13) disconnect.
33
00000002 00000000 
H12
Optical module temp sensor disconnected
DMD temp sensor disconnected. Connector (G14) disconnect.
34
00000004 00000000
H13
Exhaust air temp sensor disconnected
Exhaust air temp sensor disconnected. Connector (M11/BR13) disconnect.
35
00000008 00000000
H18
Filter clog sensor disconnected
Filter clog sensor disconnected. Connector (M21) disconnect.
36
00000010 00000000
U04
Filter clogged warning
Air filter clogged.
37
00000020 00000000
H01
Battery replacement for internal clock
Battery level is low.
38
00000040 00000000
FL1
LD1 failed to light
LD1 lighting failure
39
00000080 00000000
FL2
LD2 failed to light
LD2 lighting failure
40
00000100 00000000
U76
No air filter installed
No air filter installed
41
00000200 00000000
Not used
42
00000400 00000000
FE1/(F50) FAN 1 (RADIATOR1) error/(warning)
Fan or fan drive circuit is failure
Fan replacement time
43
00000800 00000000
FE2/(F51)  FAN 2 (RADIATOR2) error/(warning)
44
00001000 00000000
FE3/(F52)  FAN 3 (RADIATOR3) error/(warning)
45
00002000 00000000
FE4/(F53) FAN 4 (RADIATOR4) error/(warning)
46
00004000 00000000
FE5/(F54) FAN 5 (RADIATOR5) error/(warning)
47
00008000 00000000
FE6/(F55) FAN 6 (RADIATOR6) error/(warning)
48
00010000 00000000
FE7/(F56) FAN 7 (EXHAUST1) error/(warning)
49
00020000 00000000
FE8/(F57) FAN 8 (EXHAUST2) error/(warning)
50
00040000 00000000
FE9/(F58) FAN 9 (INTAKE1) error/(warning)
51
00080000 00000000
FF0/(F59) FAN 10 (INTAKE2) error/(warning)
52
00100000 00000000
FF1/(F70) FAN 11 (COLOR PRISM1) error/(warning)
53
00200000 00000000
FF2/(F71) FAN 12 (COLOR PRISM2) error/(warning)
54
00400000 00000000
FF3/(F72) FAN 13 (BLUE DMD) error/(warning)
55
00800000 00000000
FE4/(F73) FAN 14 (DMD EXHAUST1) error/(warning)
56
01000000 00000000
FF5/(F74) FAN 15 (DMD EXHAUST2) error/(warning)
57
02000000 00000000
FF6/(F75) FAN 16 (INTAKE CIRCUIT1) error/(warning)
58
04000000 00000000
FF7/(F76) FAN 17 (INTAKE CIRCUIT2) error/(warning)
59
08000000 00000000
FF8/(F77) FAN 18 (LD DRIVER) error/(warning)
60
10000000 00000000
Not used
61
20000000 00000000
FJ0/(F00) PUMP 1  error/(warning)
Liquid cooling pump drive circuit is failure
Liquid cooling unit replacement time
62
40000000 00000000
FJ1/(F01) PUMP 2  error/(warning)
63
80000000 00000000
Not used
INF-36
SECTION 1 SERVICE INFORMATION
< RQ13K >
Bit
Error code (hex)
Self-test 
indication Details
Probable cause
64
U
PP
ER
00000000 00000001
Not used
65
00000000 00000002
Not used
66
00000000 00000004
F11
Shutter error
Shutter operation is abnormal
67
00000000 00000008
Not used
68
00000000 00000010
U25
LD1 temperature error
External temperature is too high. Lack of cooling liquid
Liquid cooling unit
 deterioration. Radiator clogged 
Out of usage with high altitude
69
00000000 00000020
U26
LD2 temperature error
70
00000000 00000040
Not used
71
00000000 00000080
Not used
72
00000000 00000100
H14
LD1 temp sensor disconnected
LD1 temp sensor disconnected, disconnecting of connector (DR8)
73
00000000 00000200
H15
LD2 temp sensor disconnected
LD2 temp sensor disconnected, disconnecting of connector (RT15)
74
00000000 00000400
Not used
75
00000000 00000800
Not used
76
00000000 00001000
U16
LD1 temperature warning
External temperature is too high. Lack of cooling liquid
Liquid cooling unit
 deterioration. Radiator clogged 
Out of usage with high altitude
77
00000000 00002000
U17
LD2 temperature warning
78
00000000 00004000
Not used
79
00000000 00008000
Not used
80
00000000 00010000
F91
FPGA1 configuration error
Failure on signal processing block
81
00000000 00020000
F92
FPGA2 configuration error
82
00000000 00040000
F90
FPGA configuration error
83
00000000 00080000
FA9
CPLD configuration error
84
00000000 00100000
F87
FPGA3 configuration error
85
00000000 00200000
F88
FPGA4 configuration error
86
00000000 00400000
F96
Lens mounter operation error
Stepping motor operation failure 
Position detection sensor failure
87
00000000 00800000
F61
LD1 driver communication error
Communication error with LD1 driver
88
00000000 01000000
F62
LD2 driver communication error
Communication error with LD2 driver
89
00000000 02000000
FA8
Disable of recovery for LD1 open failure
LD1 lighting failure
90
00000000 04000000
FC8
Disable of recovery for LD2 open failure
LD2 lighting failure
91
00000000 08000000
Not used
92
00000000 10000000
FL1
LD1 lighting failure
LD1 lighting failure
93
00000000 20000000
FL2
LD2 lighting failure
LD2 lighting failure
94
00000000 40000000
UA0
Power circuit temperature warning
Temperature of power circuit is to high.
95
00000000 80000000
Not used
96
00000001 00000000
F65
LD sub microprocessor error
Device failure on DR board.
97
00000002 00000000
UA4
Power circuit temperature error
temperature of power circuit is too high.
98
00000004 00000000
A08
Communication error with sub microprocessor 
(R8)
Communication error with sub microprocessor.
99
00000008 00000000
A41
IIC communication error 1(RTC)
Device failure on signal processing block.
100
00000010 00000000
A42
IIC communication error 2 (EEPROM)
101
00000020 00000000
Not used
102
00000040 00000000
Not used
103
00000080 00000000
Not used
104
00000100 00000000
Not used
105
00000200 00000000
A47
IIC communication error 7 (EDID DIGITAL)
Device failure on signal processing block.
106
00000400 00000000
Not used
107
00000800 00000000
A49
IIC communication error 9 (ADC1)
Device failure on signal processing block.
108
00001000 00000000
A50
IIC communication error 10 (ADC2)
109
00002000 00000000
A51
IIC communication error 11 (ACCELERATION 
SENSOR)
110
00004000 00000000
A52
IIC communication error 12 (OPTICAL 
SENSOR)
111
00008000 00000000
A53
IIC communication error 13 (HD BaseT)
112
00010000 00000000
A54
IIC communication error 14 (ATM SENSOR)
113
00020000 00000000
FC1
VCM microprocessor communication error
114
00040000 00000000
F17
Quad Pixel Drive unit error
WOBBLING UNIT failure.
115
00080000 00000000
F89
FPGA5/6 configuration error
Device failure on signal processing block.
116
00100000 00000000
F81
FM-R TEST Fail
Abnormal boot mode on FM circuit. 
Error of memory test on FM circuit.
117
00200000 00000000
F82
FM-G TEST Fail
118
00400000 00000000
F83
FM-B TEST Fail
119
00800000 00000000
Not used
120
01000000 00000000
Not used
121
02000000 00000000
UA5
FPGA temperature error
Temperature of FPGA3 is too high.
122
04000000 00000000
A97
FM communication error
Communication error with FM circuit.
123
08000000 00000000
UA1
FPGA temperature warning
Temperature of FPGA3 is too high.
124
10000000 00000000
A97
GEOMETRY communication error 
Device failure on signal processing block.
125
20000000 00000000
Not used
126
40000000 00000000
FC2
FRC error
Program transfer error to FRC
127
80000000 00000000
FC0
Power microprocessor communication error
Communication error with power microprocessor.
INF-37
SECTION 1 SERVICE INFORMATION
< RQ13K >
5. 4. Troubleshooting
* The letters in the left of inspection items indicate the P.C. Boards related to their respective descriptions.
* Please take care for electro-static discharges by using grounded wrist straps to release the electricity from the body.
■ Power does not turn ON. ([STANDBY/ON] LED does not light in red)
Check the connection of each connector
    PB4-J4,   G17-R1
 NG
Connect the cables firmly
J
Check the voltage [3.3V] at pin-1 of connector [J4].
 NG
PF
PB
Cable connector connection check
      PF5-PB1/PB2, PB5-DF3/A1
Replace the [PF] or [PB] P.C.Board
G Check and replace the [G] P.C.Board
OK
OK
■ Power does not turn ON. ([STANDBY/ON] LED blinks 3 times)
Check the connection of each connector
    PB3-G18, PB4-J4, PB5-A1/DF3, MA3-G24/J3, G17-R1, 
Check the connector (B to B) on each P.C.Board
    MA / A / DG / DF / DP / G
 NG
Connect the cables firmly
A Check and replace [A] P.C. Board.
A Check the voltage [3.3V] at  pin 1 of connector [A1].
Check the voltage [5V] at pin 3 of connector [A1].
 NG
PB Check and replace [PB] P.C. Board.
OK
OK
INF-38
SECTION 1 SERVICE INFORMATION
< RQ13K >
■ Light source does not turn on. (Both of [LIGHT1,LIGHT2] LED blink 3 times)
■ Light source does not turn on. (Either of [LIGHT1,LIGHT2] LED blinks 3 times)
■ Light source does not turn on. (Either of [LIGHT1,LIGHT2] LED blinks twice)
Check the connection of each connector.
PF3/PF4–D1, G5/G6–D3, D2–DR2/DR5
DR1/DR3/DR4/DR6–LD
 NG
Connect the cables firmly.
Check the connection of each connector.
PF3/PF4–D1, G5/G6–D3, D2–DR2/DR5
DR1/DR3/DR4/DR6–LD
 
NG
Connect the cables firmly.
Check up the failure part on the LD with the self-check or logs.
D
Check the driver input voltage.
Check the voltage [DC380V] between pin 1 and 3, and voltage 
[DC16V] between pin 4 and 3 of connector [D1] at the lighting 
mode.
 NG
PF
PB
Replace [PF] or [PB] P.C.Board
D
Check the driver input voltage.
Check the voltage [DC380V] between pin 1 and 3, and voltage 
[DC16V] between pin 4 and 3 of connector [D1] at the lighting 
mode.
 
NG
PF
PB Replace [PF] or [PB] P.C.Board
D
Check the connection of each connector.
D2–DR2/DR5, DR1/DR3/DR4/DR6–LD
 
NG
Connect the cables firmly.
D
Check the driver input voltage.
Check the voltage [DC12V] at pin 13 of connector [D3] at the 
lighting mode.
 NG
G
Replace [G] P.C.Board
D
DR Replace [D] or [DR] P.C.Board
D
DR Replace [D] or [DR] P.C.Board
Replace appropriate LD unit.
OK
OK
OK
OK
OK
OK
OK
Page of 127