DOWNLOAD Panasonic PT-CW240U / PT-CW240E / PT-CW240EA / PT-CW330U / PT-CW330E / PT-CW330EA / PT-CX300U / PT-CX300E / PT-CX300EA / PT-CW241RU / PT-CW241RE / PT-CW241REA / PT-CW331RU / PT-CW331RE / PT-CW331REA / PT-CX301RU / PT-CX301RE / PT-CX301REA Service Manual ↓ Size: 25.34 MB | Pages: 84 in PDF or view online for FREE

Model
PT-CW240U PT-CW240E PT-CW240EA PT-CW330U PT-CW330E PT-CW330EA PT-CX300U PT-CX300E PT-CX300EA PT-CW241RU PT-CW241RE PT-CW241REA PT-CW331RU PT-CW331RE PT-CW331REA PT-CX301RU PT-CX301RE PT-CX301REA
Pages
84
Size
25.34 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector / DLP BASED PROJECTOR
File
pt-cw240u-pt-cw240e-pt-cw240ea-pt-cw330u-pt-cw330e.pdf
Date

Panasonic PT-CW240U / PT-CW240E / PT-CW240EA / PT-CW330U / PT-CW330E / PT-CW330EA / PT-CX300U / PT-CX300E / PT-CX300EA / PT-CW241RU / PT-CW241RE / PT-CW241REA / PT-CW331RU / PT-CW331RE / PT-CW331REA / PT-CX301RU / PT-CX301RE / PT-CX301REA Service Manual ▷ View online

PT-CW240/PT-CX300/PT-CW330
4-1
Chapter 4
Function Test & Alignment Procedure
4-1 Run In Test 
- Temperature: 15°C~35°C
- Circumstance brightness: Normal environment
- Screen size: No concern
- Display mode: ECO mode
After repairing each unit, a Ru
n-in test is necessary (refer to the below table).
Symptom
Run-in Time
Normal repair
2 hours
NFF
4 hours
Auto shutdown
6 hours
- Get into Burn-In Mode
*  Cycle setting is based on the defect symptoms. ie: If it is NFF, the run-in time is 4 hours. You have 
to set the lamp on for 50 min. and lamp off for 10 min for 4 cycles.
Press POWER > Left >Right > MENU buttons sequentially on remote controller or on the top 
panel to get into service mode.
Choose Burn-In Test > MENU
Lamp On
Press right key to adjust the time (50)
Lamp Off
Press right key to adjust the time (10)
Set burn in cycle
Press right key to adjust the cycle
After setting up the time, choose “Enter Burn-In Mode” and press "MENU".
The projector will start testing.
PT-CW240/PT-CX300/PT-CW330
4-2
4-2 Test Inspection Procedure
1. Check Points 
Check item
Check point
Firmware version 
All firmware version must be the latest version
TB implementation   
Related TB must be implement 
Cosmetic
Cosmetic can not be broken
Logo
Missing logo, missing prints and blurry prints are
unacceptable
Lamp cover
It should be locked in the correct place.
Zoom in/out
The function should work smoothly
Keypad 
All keypad buttons must operate smoothly
2. OSD Reset 
After final QC step, we have to erase all saved change again and restore the OSD  
    default setting. The following actions will allow you to erase all end-users' settings and    
    restore the default setting:
  (1) Please enter OSD menu.
  (2) Choose "Options" and then execute "Reset" function
PT-CW240/PT-CX300/PT-CW330
4-3
 
(240/255)white    
/(15/255)Black
4-3 Calibration
1. ADC Calibration
Note: After replacing main board or upgrading firmware, the ADC calibration 
         should be done.
Procedure 
 
- Test equipment: video generator 
                                     (1) Test signal:  1280 x 800@60Hz for PT-CW330/
CW240
1024 x 768@60Hz for PT-CX300
(2) Test Pattern: (240/255)white/(15/255)Black
 
 
- Note
                                     (1) Calibration pattern should be in full screen mode.
                                     (2)  Press POWER > Left >Right > MEMU buttons 
sequentially on remote controller or on the top 
panel to get into service mode. Choose “ADC                                         
Calibration” from the service mode menu.
Inspection item  
- Check if there is lines or noise on the screen.
 
 
-  Horizontal and vertical position of the video should be 
adjustable to the screen frame.
Criteria 
 
-  If there is noise on the screen, the product is consid-
ered as failure product.
 
 
- The screen appears normal, it shouldn’t appear    
 
 
  any abnormal condition, such as lines and so on.
- Check if the projection is same as monitor displayed.
PT-CW240/PT-CX300/PT-CW330
4-4
4-4 Waveform download
After replacing Lamp driver, the “waveform  
      download” is needed as below.
1. Hold on [POWER] and [MENU] button and plug in the  
power cord. The [POWER] LED will flash in red.
2. Release the [POWER] and [MENU] buttons in 2s.
3. The [POWER] LED flashes in red and green alternately.
4. Press [POWER] button. The [POWER] LED will light in
green for about 5s add then turnes red.
5. The waveform download is complete.
Note: 
       - Check whether execute auto Waveform download, 
         if not, repeat the step again.