Panasonic KX-MB1500UCW / KX-MB1520UCB Service Manual ▷ View online
117
KX-MB1500UCW/KX-MB1520UCB
12.3.6.2. CALL SERVICE 2
"CALL SERVICE 2" means that the synchronous signal out of the LSU cannot be detected.
The synchronous signal out of the LSU is detected by IC 300-G23pin. (NHSYNC)
The synchronous signal out of the LSU is detected by IC 300-G23pin. (NHSYNC)
Note:
As for the "Pulse" waveform of the above flow chart, see the timing chart.
118
KX-MB1500UCW/KX-MB1520UCB
12.3.6.3. CALL SERVICE 3
"CALL SERVICE 3" means that the temperature of the fuser does not rise up to or exceed a constant temperature.
The temperature is monitored with the thermistor inside the fuser and detected with the voltage input into IC 300-D19.
The temperature is monitored with the thermistor inside the fuser and detected with the voltage input into IC 300-D19.
* When Call Service 3 is occurred, the cause can be distinguished by service mode 655.
Refer to CALL SERVICE Troubleshooting Guide (P.115) for details.
Refer to CALL SERVICE Troubleshooting Guide (P.115) for details.
119
KX-MB1500UCW/KX-MB1520UCB
12.3.6.4. CALL SERVICE 4
"CALL SERVICE 4" means that the FAN does not rotate or the rotation of the FAN cannot be detected normally.
120
KX-MB1500UCW/KX-MB1520UCB
12.3.6.5. CALL SERVICE 17
“CALL SERVICE 17” means that the First use sensor problem.
Especially "CALL SERVICE 17" is appeared when the fuse which is installed in the Drum Unit PCB is not blown out within a specific
time.
Especially "CALL SERVICE 17" is appeared when the fuse which is installed in the Drum Unit PCB is not blown out within a specific
time.