11.1.5. Memory Clear Specification
*
1
Execute Service Mode #550 when you want to reset the all setting data keeping the user information.
*
2
Execute Service Mode #710 to clear the user information in case that Main Unit is recycled.
Note:
Please restart a power supply after clearing a memory.
763
CNG detect time for friendly reception 1:10 sec
2:20 sec
3:30 sec
3:30 sec
1~3
3
Selects the CNG detection tone of friendly recep-
tion.
tion.
774
Receiving T4 timer
X 100 msec
00~99
00
Use this function when delay occurs in the line and
communication.
(ex. Mobile comm) does not work well.
communication.
(ex. Mobile comm) does not work well.
775
Transmission T4 timer
X 100m sec
00~99
00
Use this function when delay occurs in the line and
communication.
(ex. Mobile comm) does not work well.
communication.
(ex. Mobile comm) does not work well.
815
Sensor check
See Test Functions (P.86).
852
Print test pattern
See Test Functions (P.86).
853
Top margin
X 0.5mm
01~11
06
----------
854
Left margin
X 0.5mm
01~11
06
----------
874
DTMF ON time
X msec
060~200
100
----------
875
DTMF OFF time
X msec
060~200
100
----------
880
History list
See History (Example of a printed out list)
(P.98).
(P.98).
881
Journal 2 list
See Journal 2 (P.141).
882
Journal 3 list
See Journal 3 (P.142).
Code
Function
Set Value
Effective
Range
Default
Remarks
94
KX-MB1500UCW/KX-MB1520UCB
11.2. User Mode (The list below is an example of the SYSTEM SETUP LIST
the unit prints out.)
(KX-MB1500)
Note:
The above values are the default values.
95
KX-MB1500UCW/KX-MB1520UCB
(KX-MB1520)
96
KX-MB1500UCW/KX-MB1520UCB
Note:
The above values are the default values.