89
KX-MB1500UCW/KX-MB1520UCB
10.1.4. Print Test Pattern
1. NO.01
2. NO.06
3. NO.03
• These print test patterns are just image printing, and differ-
ent from actual ones.
• When it is required to judge the print quality, compare with
the printing of a nondefective machine.
90
KX-MB1500UCW/KX-MB1520UCB
11 Service Mode
The programming functions are used to program the various features and functions of the machine, and to test the machine.
This facilitates communication between the user and the service man while programming the unit.
11.1. Programming and Lists
11.1.1. Operation
There are 2 basic categories of programming functions, the User Mode and the Service Mode. The Service Mode is further broken
down into the normal and special programs. The normal programs are those listed in the Operating Instructions and are available to
the user. The special programs are only those listed here and not displayed to the user. In both the User and Service Modes, there
are Set Functions and Test Functions. The Set Functions are used to program various features and functions, and the Test Func-
tions are used to test the various functions. The Set Functions are accessed by entering their code, changing the appropriate value,
then pressing the SET key. The Test Functions are accessed by entering their code and pressing the key listed on the menu. While
programming, to cancel any entry, press the STOP key.
Note:
When changing the set values on the service function table, they should not be set beyond the local regulation.
Follow the laws and regulations of your area.
11.1.2. Operation Flow
91
KX-MB1500UCW/KX-MB1520UCB
11.1.3. Service Function Table (KX-MB1500)
11.1.4. Service Function Table (KX-MB1520)
Code
Function
Set Value
Effective 
Range
Default
Remarks
529
Call Service Clear
550
Memory clear
Refer to Memory Clear Specification (P.93).
551
ROM check
See Test Functions (P.86).
555
Scanner test
See Test Functions (P.86).
556
Motor test
0
See Test Functions (P.86).
557
LED test
See Test Functions (P.86).
558
LCD test
See Test Functions (P.86).
561
KEY test
See Test Functions (P.86).
628
H.V.P.S. check
See Test Functions (P.86).
639
LSU test
See Test Functions (P.86).
655
Cause Distinction Code of Call Service 3
See  CALL SERVICE Troubleshooting Guide
(P.115).
677
FAN test
See Test Functions (P.86).
710
Memory clear except History data
Refer to Memory Clear Specification (P.93).
815
Sensor check
See Test Functions (P.86).
852
Print test pattern
See Test Functions (P.86).
853
Top margin
1~11
6
 ---------- 
854
Left margin
1~11
6
 ---------- 
880
History list
See  History (Example of a printed out list)
(P.98)
.
Code
Function
Set Value
Effective 
Range
Default
Remarks
501
Pause time set 
X 100 msec
001~600
035
 ---------- 
503
Dial speed select 
1:10 pps 
2:20 pps
1, 2
1
 ---------- 
507
V34 transmission start speed 
0: Disable
1: 33.6
2: 31.2
3: 28.8
4: 26.4
5: 24.0
6: 21.6
7: 19.2
8: 16.8
0~8
1
If the code 527 is set at 2, the code 507 and 508
work.
508
V34 reception start speed 
0: Disable
1: 33.6
2: 31.2
3: 28.8
4: 26.4
5: 24.0
6: 21.6
7: 19.2
8: 16.8
0~8
1
If the code 527 is set at 2, the code 507 and 508
work.
514
Bell signal detect time 
X 100msec
1~9
6
 ---------- 
520
CED frequency select
1:2100 Hz
2:1100 Hz
1, 2
1
See How To Output The Journal Report (P.144).
521
International mode select 
1:ON   2:OFF 1, 2
1
See How To Output The Journal Report (P.144).
522
Auto standby select
1:ON   2:OFF 1, 2
1
The resolution reverts to the default when transmis-
sion is complete.
523
Receive equalizer select
1: 0 km
2: 1.8 km
3: 3.6 km
4: 7.2 km
1~4
1
Set RX equalizer to automatic mode.
524
Transmission equalizer select 
1: 0 km
2: 1.8 km
3: 3.6 km
4: 7.2 km
1~4
1
527
V.8 function select 
1:OFF   2:ON 1, 2
2
529
Call Service Clear
550
Memory clear
Refer to Memory Clear Specification (P.93).
92
KX-MB1500UCW/KX-MB1520UCB
551
ROM check
See Test Functions (P.86).
552
DTMF single tone test
1:ON   2:OFF 1, 2
2
See Test Functions (P.86).
553
Monitor on FAX communication
select 
1:OFF   
2:PHASE B
3:ALL
1~3
1
Sets whether to monitor the line signal with the
unit's speaker during FAX communication or not.
554
Modem test
See Test Functions (P.86).
555
Scanner test
See Test Functions (P.86).
556
Motor test
0
See Test Functions (P.86).
557
LED test
See Test Functions (P.86).
558
LCD test
See Test Functions (P.86).
561
KEY test
See Test Functions (P.86).
567
T0 timer
X second
001~255
031
Sets a higher value when the response from the
other party needs more time during automatic FAX
transmission.
570
BREAK% select
1:61%   2:67%
3:63%
1, 2, 3
1
Sets the% break of pulse dialing according PBX.
573
Remote turn-on ring number set
X  number  of
rings
00~99
00
Sets the number of rings before the unit starts to
operate TAM in the TEL mode.
574
Dial tone detect check
1: ON   2: OFF 1, 2
2
 ---------- 
590
FAX auto redial time set
X  number  of
times
00~99
03
Selects the number of redial times during FAX com-
munication (not including the first dial).
591
FAX auto redial time disconnection
time set
X second
001~999
065
Sets the FAX redial interval during FAX communi-
cation.
592
CNG transmit select 
1:OFF
2:ALL
3:AUTO
1~3
2
Lets you select the CNG output during FAX trans-
mission. ALL: CNG is output at phase A. AUTO:
CNG id output only when automatic dialing is per-
formed. OFF: CNG id not output at phase A. Refer
to  Sometime There is a Transmit Problem
(P.137).
593
Time between CED and 300bps
1:75 msec
2:500 msec
3:1 sec
1~3
1
See How To Output The Journal Report (P.144)
and Receive Problem (P.138).
594
Overseas DIS detection select
1:detects 
at
the 1st time
2:detects at
the 2nd time
1, 2
1
See How To Output The Journal Report (P.144)
and  Sometime There is a Transmit Problem
(P.137).
595
Receive error limit value set
1: 5%
2: 10%
3: 15%
4: 20%
1~4
2
If the number of errors during transmission exceeds
this value, the sending side terminates the call.
596
Transmit level set 
X dBm
 - 15~00
10
Selects the FAX transmission level. Refer to Some-
time There is a Transmit Problem
 (P.137)
 and
Receive Problem (P.138).
598
Receiving sensitivity 
43= -43 dBm
20~48
48
Used when there is an error problem. Refer to How
To Output The Journal Report
 (P.144)
.
599
ECM frame size 
1:256 2:64
1, 2
1
 ---------- 
628
H.V.P.S. check
See Test Functions (P.86).
639
LSU test
See Test Functions (P.86).
655
Cause Distinction Code of Call Service 3
See  CALL SERVICE Troubleshooting Guide
(P.115).
677
FAN test
See Test Functions (P.86).
710
Memory clear except History data
Refer to Memory Clear Specification (P.93).
711
Dialing mode
1:PULSE
2:TONE
1,2
1
717
Transmit speed select
1:14400BPS
2:12000BPS
3:9600BPS
4:7200BPS
5:4800BPS
6:2400BPS
1~6
1
If the code 527 is set at 1, the code 717 and 718
work.
718
Receive speed select 
1:14400BPS
2:12000BPS
3:9600BPS
4:7200BPS
5:4800BPS
6:2400BPS
1~6
1
If the code 527 is set at 1, the code 717 and 718
work.
721
Pause tone detect 
1:ON   2:OFF 1, 2
2
Selects the tone detection for pause in dialing.
722
Redial tone detect 
1:ON   2:OFF 1, 2
1
Sets the tone detection mode after redialing.
Code
Function
Set Value
Effective 
Range
Default
Remarks
Page of 127