Panasonic TX-P65VT60Y / TX-PR65VT60 Service Manual ▷ View online

21
7.2.
Power LED Blinking timing chart
1. Subject
Information of LED Flashing timing chart.
2. Contents
When an abnormality has occurred the unit, the protection circuit operates and reset to the stand by mode. At this time, the 
defective block can be identified by the number of blinks of the Power LED on the front panel of the unit.
* Use SC jig to isolate the board.
Blinking Times
Contents
Check point
1
Panel information SOS
PD Start SOS
-
2
P15V SOS 
A-Board
P-Board
6
Driver SOS1
(SC Energy recovery circuit)
(A-SC FPC DET)
SC-Board
A-SC FPC
7
Driver SOS2
(SU/SD Connector DET)
(SU/SD Scan and Logic IC)
SU-Board
SD-Board
*
8
Driver SOS3
(SS FPC DET)
(SS Energy recovery circuit)
SS-Board
SS2-Board
SS FPC
SS2 FPC
9
Discharge Control SOS
A-Board
10
Sub 3.3V SOS
Tuner power SOS
A-Board
SC-Board
SS-Board
P-Board
11
Fan SOS
A-Board
12
Sound SOS
A-Board
Speaker
Woofer
13
Emergency SOS
A-Board
22
7.3.
No Power
First check point
There are following 3 states of No Power indication by power LED.
1. No lit
2. Green is lit then turns red blinking a few seconds later. (See Power LED Blinking timing chart)
3. Only red is lit.
7.4.
No Picture
7.4.1.
Drive circuits LED indicator
Check that the following  LEDs on the SC and SS-Board.
Power recovery LED
LED for check
SC
D16583
SS
D16254A
23
7.5.
Local screen failure
Plasma display may have local area failure on the screen. Fig-1 is the possible defect P.C.B. for each local area.
Fig-1
24
8 Service Fixture & Tools
8.1.
SC jig
Purpose:
To find the failure board (SC or SU/SD) when the power LED is blinking 7 times.
SC jig:
Jumper connector to connect to SC50 connector on SC board
Part number:
TZSC09187
How to use:
Caution: Remove SC jig from SC board after inspection.
1. Remove the 3 VFG screws from SU and SD board.
2. Remove all connector between SC board and SU/SD board to isolate SC board from both SU and SD board electrically.
Note: The board will be damaged if all connector is not removed (for example; remove connector only for SU board and stay 
connecting with SD board. The board will be damaged.)
3. Connect SC jig to connector SC50 at left bottom side of SC board
4. Turn on the TV/Display Unit and confirm the power LED blinking.
LED blinking: Possible cause of failure is in SC board
No LED blinking (Lighting or no lighting): Possible cause of failure is in SU or SD board
5. After inspection, turn off the TV/Display Unit and wait a few minutes to discharge.
6. Remove SC jig from SC board.
Remark: This SC jig can be used for all 2013 Plasma TV and Plasma Display.