DOWNLOAD Panasonic KX-NSX1000 / KX-NSX2000 (serv.man2) Service Manual ↓ Size: 9.94 MB | Pages: 127 in PDF or view online for FREE

Model
KX-NSX1000 KX-NSX2000 (serv.man2)
Pages
127
Size
9.94 MB
Type
PDF
Document
Service Manual
Brand
Device
PBX / BUSINESS COMMUNICATION SERVER
File
kx-nsx1000-kx-nsx2000-sm2.pdf
Date

Panasonic KX-NSX1000 / KX-NSX2000 (serv.man2) Service Manual ▷ View online

85
KX-NSX1000/KX-NSX2000
GMII/RGMII/MII Interface(Port 5)
GMII/RGMII/MII Interface(Port 6)
System and Register Access Interface
Switch Configuration Interface
Pin No.
Signal Name
I/O
Function
73
P5_RGMII_EN
I
Port 5’s GMII/RGMII/MII Interface Enable(generically referred to as RGMII5)
85
P5_INCLK
I
Input Clock
91
P5_IND[3]
I
Input Data
90
P5_IND[2]
I
89
P5_IND[1]
I
88
P5_IND[0]
I
86
P5_INDV
I
Input Data Valid
94
P5_CRS/MDC_PHY
I/O
Carrier Sense or Management Data Clock, Master
95
P5_COL/MDIO_PHY
I/O
Collicion or Management Data I/O, Master
82
P5_GTXCLK/
P5_VDDOS[0]
O
Transmit Clock
81
P5_OUTEN/
P5_VDDOS[1]
O
Output Enable
83
P5_OUTCLK
I
Output Clock
76
P5_OUTD[3]/
P5_MODE[1]
O
Output Data
77
P5_OUTD[2]/
P5_MODE[0]
O
78
P5_OUTD[1]/
P5_ADDR[1]
O
79
P5_OUTD[0]/
P5_ADDR[0]
O
Pin No.
Signal Name
I/O
Function
96
P6_RGMII_EN
I
Port 6’s GMII/RGMII/MII Interface Enable(generically referred to as RGMII6)
108
P6_INCLK
I
Input Clock
114
P6_IND[3]
I
Input Data
113
P6_IND[2]
I
112
P6_IND[1]
I
111
P6_IND[0]
I
109
P6_INDV
I
Input Data Valid
117
P6_CRS/MDC_PHY
I/O
Carrier Sense or Management Data Clock, Master
118
P6_COL/GPIO[1]
I/O
Collicion or Management Data I/O, Master
105
P6_GTXCLK/
P6_VDDOS[0]
O
Transmit Clock
104
P6_GTXCLK/
P6_VDDOS[1]
O
Output Enable
106
P6_OUTCLK
I
Output Clock
99
P6_OUTD[3]/
P6_MODE[1]
I
Output Data
100
P6_OUTD[2]/
P6_MODE[0]
I
101
P6_OUTD[1]/
P6_ADDR[1]
I
102
P6_OUTD[0]/
P6_ADDR[0]
I
Pin No.
Signal Name
I/O
Function
70
MDC_CPU
I
Management Data Clock, Slave.
71
MDIO_CPU
I/O
Management Data I/O, Slave
72
INTn
D
INTn is an active low, open drain pin that is asserted to indicate an unmasked 
interrupt event occurred
68
RESETn
I
Hardware reset. Active low.
Pin No.
Signal Name
I/O
Function
66
SW_MODE[1]
I, PU
Switch Mode. These pins are used to configure the device after reset. Switch 
mode pins work as follows:
67
SW_MODE[0]
I, PD
00=Test mode
01=Reserved
10=Unmanaged/Forwarding mode (default)
11=CPU Attached/Disabled mode
86
KX-NSX1000/KX-NSX2000
Reference and Clock
Power and Ground
Pin No.
Signal Name
I/O
Function
32
RESET
Analog
Resistor Current reference. A 4.99 kohm 1% resistor is placed between the 
RSET and VSS
37
XTAL_IN
I
25 MHz system reference clock input provided from the board
38
XTAL_OUT
O
System reference clock output provided from the board
35
XTAL_GND
I
Analog Ground for the XTAL.
Pin No.
Signal Name
I/O
Function
75
P5_VDDO
Power
P5_VDDO must be connected to 3.3V  for 3.3V I/O, 2.5V for 2.5V I/O or 1.8V for 
1.8V I/O
84
P5_VDDO
Power
92
P5_VDDO
Power
98
P6_VDDO
Power
P6_VDDO must be connected to 3.3V  for 3.3V I/O, 2.5V for 2.5V I/O or 1.8V for 
1.8V I/O
107
P6_VDDO
Power
115
P6_VDDO
Power
122
EE_VDDO
Power
EE_VDDO must be connected to 3.3V for 3.3V I/O or 2.5V for 2.5V I/O.
127
EE_VDDO
Power
61
P4_AVDD
Power
1.8V Power to analog core used to power each Gig PHY interface
56
P4_AVDD
Power
51
P3_AVDD
Power
46
P3_AVDD
Power
29
P2_AVDD
Power
24
P2_AVDD
Power
19
P1_AVDD
Power
14
P1_AVDD
Power
9
P0_AVDD
Power
4
P0_AVDD
Power
33
AVDD
Power
Gigabit PHY 1.8V power to analog core used to power the on-chip PLL.
39
AVDD
Power
41
VDDO_S
Power
VDDO_S must be connected to 3.3V for 3.3V I/O, or 2.5V for 2.5V I/O
40
VDDO_CORE
Power
1.0V power to the digital core
43
VDDO_CORE
Power
69
VDDO_CORE
Power
74
VDDO_CORE
Power
80
VDDO_CORE
Power
87
VDDO_CORE
Power
93
VDDO_CORE
Power
97
VDDO_CORE
Power
103
VDDO_CORE
Power
110
VDDO_CORE
Power
116
VDDO_CORE
Power
EPAD
EPAD
Ground
Ground to device.
34
NC
-
No Connect.
36
NC
-
42
NC
-
64
NC
-
65
NC
-
87
KX-NSX1000/KX-NSX2000
15.1.3.
CN1 (COM Express Module Connector)
Pin no.
Pin name
Signal Name
Pin no.
Pin name
Signal Name
A1
GND(FIXED)
GND
B1
GND(FIXED)
GND
A2
GBE0_MDI3-
CEX_MDI3_N_L2SW#1
B2
GBE0_ACT#
CEX_ACTn_LED
A3
GBE0_MDI3+
CEX_MDI3_P_L2SW#1
B3
LPC_FRAME#
unused
A4
GBE0_LInK100#
CEX_LINK100n_LED
B4
LPC_AD0
unused
A5
GBE0_LInK1000#
CEX_LINK1000n_LED
B5
LPC_AD1
unused
A6
GBE0_MDI2-
CEX_MDI2_N_L2SW#1
B6
LPC_AD2
unused
A7
GBE0_MDI2+
CEX_MDI2_P_L2SW#1
B7
LPC_AD3
unused
A8
GBE0_LINK#
unused
B8
LPC_DRQ0#
Unused, Pull up
A9
GBE0_MDI1-
CEX_MDI1_N_L2SW#1
B9
LPC_DRQ1#
Unused, Pull up
A10
GBE0_MDI1+
CEX_MDI1_P_L2SW#1
B10
LPC_CLK
unused
A11
GND(FIXED)
GND
B11
GND(FIXED)
GND
A12
GBE0_MDI0-
CEX_MDI0_N_L2SW#1
B12
PWRBTn#
unused
A13
GBE0_MDI0+
CEX_MDI0_P_L2SW#1
B13
SMB_CK
unused
A14
GBE0_CTREF
CEX_CTREF_L2SW#1
B14
SMB_DAT
unused
A15
SUS_S3#
CEX_SUS_nS3
B15
SMB_ALERT#
unused
A16
SATA0_TX+
CEX_SSD#1_TX_P
B16
SATA1_TX+
CEX_SSD#2_TX_P
A17
SATA0_TX-
CEX_SSD#1_TX_N
B17
SATA1_TX-
CEX_SSD#2_TX_N
A18
SUS_S4#
unused
B18
SUS_STAT#
unused?
A19
SATA0_RX+
CEX_SSD#1_RX_P
B19
SATA1_RX+
CEX_SSD#2_RX_P
A20
SATA0_RX-
CEX_SSD#1_RX_N
B20
SATA1_RX-
CEX_SSD#2_RX_N
A21
GND(FIXED)
GND
B21
GND(FIXED)
GND
A22
SATA2_TX+
not supported
B22
SATA3_TX+
not supported
A23
SATA2_TX-
not supported
B23
SATA3_TX-
not supported
A24
SUS_S5#
unused
B24
PWR_OK
PWR_OK
A25
SATA2_RX+
not supported
B25
SATA3_RX+
not supported
A26
SATA2_RX-
not supported
B26
SATA3_RX-
not supported
A27
BATLOW#
unused
B27
WDT
CEX_WDT
A28
(S)ATA_ACT#
unused
B28
AC/HDA_SDIN2
not supported
A29
AC/HDA_SYNC
unused
B29
AC/HDA_SDIN1
unused
A30
AC/HDA_RST#
unused
B30
AC/HDA_SDIN0
unused
A31
GND(FIXED)
GND
B31
GND(FIXED)
GND
A32
AC/HDA_BITCLK
unused
B32
SPKR
unused
A33
AC/HDA_SDOUT
unused
B33
I2C_CK
unused
A34
BIOS_DIS0#
unused
B34
I2C_DAT
unused
A35
THRMTRIP#
unused
B35
THRM#
unused
A36
USB6-
unused
B36
USB7-
unused
A37
USB6+
unused
B37
USB7+
unused
A38
USB_6_7_OC#
unused
B38
USB_4_5_OC#
unused
A39
USB4-
unused
B39
USB5-
unused
A40
USB4+
unused
B40
USB5+
unused
A41
GND(FIXED)
GND
B41
GND(FIXED)
GND
A42
USB2-
unused
B42
USB3-
unused
A43
USB2+
unused
B43
USB3+
unused
A44
USB_2_3_OC#
unused
B44
USB_0_1_OC#
CEX_VBUS_0_1_OCn_USB
A45
USB0-
CEX_USB_N
B45
USB1-
unused
A46
USB0+
CEX_USB_P
B46
USB1+
unused
A47
VCC_RTC
VCC_RTC
B47
EXCD1_PERST#
unused
A48
EXCD0_PERST#
unused
B48
EXCD1_CPPE#
unused
A49
EXCD0_CPPE#
unused
B49
SYS_RESET#
CEX_SYS_RESETn
A50
LPC_SERIRQ
unused
B50
CB_RESET#
CEX_CB_RESETn
A51
GND(FIXED)
GND
B51
GND(FIXED)
GND
A52
PCIE_TX5+
not supported
B52
PCIE_RX5+
not supported
A53
PCIE_TX5-
not supported
B53
PCIE_RX5-
not supported
A54
GPI0
INITIALIZE_SW
B54
GPO1
BAT_ARMn_FPGA
A55
PCIE_TX4+
not supported
B55
PCIE_RX4+
not supported
A56
PCIE_TX4-
not supported
B56
PCIE_RX4-
not supported
A57
GND
R=0?Jumper to GND
B57
GPO2
CEX_DEBUG_LED1
A58
PCIE_TX3+
not supported
B58
PCIE_RX3+
not supported
A59
PCIE_TX3-
not supported
B59
PCIE_RX3-
not supported
A60
GND(FIXED)
GND
B60
GND(FIXED)
GND
A61
PCIE_TX2+
CEX_PCIE_TX2_P_FPGA
B61
PCIE_RX2+
CEX_PCIE_RX2_P_FPGA
A62
PCIE_TX2-
CEX_PCIE_TX2_N_FPGA
B62
PCIE_RX2-
CEX_PCIE_RX2_N_FPGA
A63
GPI1
R=0?Jumper to GND
B63
GPO3
CEX_DEBUG_LED2
A64
PCIE_TX1+
CEX_PCIE_TX_P_LANC#2
B64
PCIE_RX1+
CEX_PCIE_RX_P_LANC#2
88
KX-NSX1000/KX-NSX2000
A65
PCIE_TX1-
CEX_PCIE_TX_N_LANC#2
B65
PCIE_RX1-
CEX_PCIE_RX_N_LANC#2
A66
GND
R=0   Jumper to GND
B66
WAKE0#
unused
A67
GPI2
R=0   Jumper to GND
B67
WAKE1#
unused
A68
PCIE_TX0+
CEX_PCIE_TX_P_LANC#1
B68
PCIE_RX0+
CEX_PCIE_RX_P_LANC#1
A69
PCIE_TX0-
CEX_PCIE_TX_N_LANC#1
B69
PCIE_RX0-
CEX_PCIE_RX_N_LANC#1
A70
GND(FIXED)
GND
B70
GND(FIXED)
GND
A71
LVDS_A0+
unused
B71
LVDS_B0+
unused
A72
LVDS_A0-
unused
B72
LVDS_B0-
unused
A73
LVDS_A1+
unused
B73
LVDS_B1+
unused
A74
LVDS_A1-
unused
B74
LVDS_B1-
unused
A75
LVDS_A2+
unused
B75
LVDS_B2+
unused
A76
LVDS_A2-
unused
B76
LVDS_B2-
unused
A77
LVDS_VDD_EN
unused
B77
LVDS_B3+
unused
A78
LVDS_A3+
unused
B78
LVDS_B3-
unused
A79
LVDS_A3-
unused
B79
LVDS_BKLT_En
unused
A80
GND(FIXED)
GND
B80
GND(FIXED)
GND
A81
LVDS_A_CK+
unused
B81
LVDS_B_CK+
unused
A82
LVDS_A_CK-
unused
B82
LVDS_B_CK-
unused
A83
LVDS_I2C_CK
unused
B83
LVDS_BKLT_CTRL
unused
A84
LVDS_I2C_DAT
unused
B84
VCC_5V_SBY
unused
A85
GPI3
FPGA_INT_DONE
B85
VCC_5V_SBY
unused
A86
RSVD
reserved
B86
VCC_5V_SBY
unused
A87
RSVD
reserved
B87
VCC_5V_SBY
unused
A88
PCIE_CLK_REF+
CEX_PCIE_CLK_REF_P
B88
BIOS_DIS1#
unused
A89
PCIE_CLK_REF-
CEX_PCIE_CLK_REF_N
B89
VGA_RED
unused
A90
GND(FIXED)
GND
B90
GND(FIXED)
GND
A91
SPI_POWER
unused
B91
VGA_GRn
unused
A92
SPI_MISO
unused
B92
VGA_BLU
unused
A93
GPO0
CEX_nCONFIG_FPGA
B93
VGA_HSYNC
unused
A94
SPI_CLK
unused
B94
VGA_VSYNC
unused
A95
SPI_MOSI
unused
B95
VGA_I2C_CK
unused
A96
TPM_PP
unused
B96
VGA_I2C_DAT
unused
A97
TYPE10#
unused
B97
SPI_CS#
unused
A98
SER0_TX
CEX_RS232C#1_TXD_BUF
B98
RSVD
reserved
A99
SER0_RX
CEX_RS232C#1_RXD_BUF
B99
RSVD
reserved
A100
GND(FIXED)
GND
B100
GND(FIXED)
GND
A101
SER1_TX
CEX_RS232C#2_TXD_BUF
B101
FAN_PWMOUT
Unused
A102
SER1_RX
CEX_RS232C#2_RXD_BUF
B102
FAN_TACHIN
Unused
A103
LID#
not supported
B103
SLEEP#
not supported
A104
VCC_12V
+15V
B104
VCC_12V
+15V
A105
VCC_12V
+15V
B105
VCC_12V
+15V
A106
VCC_12V
+15V
B106
VCC_12V
+15V
A107
VCC_12V
+15V
B107
VCC_12V
+15V
A108
VCC_12V
+15V
B108
VCC_12V
+15V
A109
VCC_12V
+15V
B109
VCC_12V
+15V
A110
GND(FIXED)
GND
B110
GND(FIXED)
GND
Pin no.
Pin name
Signal Name
Pin no.
Pin name
Signal Name
Page of 127
Display

Click on the first or last page to see other KX-NSX1000 / KX-NSX2000 (serv.man2) service manuals if exist.