DOWNLOAD Panasonic KX-NSX1000 / KX-NSX2000 (serv.man2) Service Manual ↓ Size: 9.94 MB | Pages: 127 in PDF or view online for FREE

Model
KX-NSX1000 KX-NSX2000 (serv.man2)
Pages
127
Size
9.94 MB
Type
PDF
Document
Service Manual
Brand
Device
PBX / BUSINESS COMMUNICATION SERVER
File
kx-nsx1000-kx-nsx2000-sm2.pdf
Date

Panasonic KX-NSX1000 / KX-NSX2000 (serv.man2) Service Manual ▷ View online

ORDER NO. KMS1512159CE
Business Communication Server
Model No.
KX-NSX1000
KX-NSX2000
Series
[ Version 4.0 ]
Ver.No
Model No.
Destination
1
KX-NSX1000BX
Asia, Middle East and Other area
KX-NSX2000BX
KX-NSX1000SX
KX-NSX2000SX
2
KX-NSX1000EX
Germany,Greece,Europe
3
India
KX-NSX1000
KX-NSX2000
4
U.S.A.
KX-NSX1000
KX-NSX2000
Russian,Kazakhstan,Ukraine
2
KX-NSX1000/KX-NSX2000
TABLE OF CONTENTS
PAGE
PAGE
1 Safety Precautions -----------------------------------------------4
1.1. For Service Technicians  ---------------------------------4
1.2. Insulation Resistance Test -------------------------------4
2 Warning --------------------------------------------------------------5
2.1. Battery Caution ---------------------------------------------5
2.1.1. Information for Users on Collection and
Disposal of Old Equipment and used
Batteries -------------------------------------------------5
2.2. Caution--------------------------------------------------------5
2.3. About Lead Free Solder (PbF: Pb free) --------------5
2.3.1. Suggested PbF Solder -------------------------------6
2.4. Discarding of P. C. Board --------------------------------6
3 Specifications ------------------------------------------------------7
4 Technical Descriptions------------------------------------------8
4.1. System Block Diagram------------------------------------8
4.2. Mother Board Block Diagram ---------------------------9
4.3. Power Supply Unit  -------------------------------------- 10
4.3.1. On Board Power Circuit Block Diagram ------- 10
4.3.2. AC Section and Rectifier Circuit ----------------- 11
4.3.3. Main Converter--------------------------------------- 12
4.3.4. Output Voltage Section ---------------------------- 13
4.3.5. Alarm Signal Transmission Section------------- 14
4.3.6. Protective Circuit Operation Section------------ 15
5 Location of Controls and Components------------------ 16
5.1. Name and Locations ------------------------------------ 16
6 Installation Instructions--------------------------------------- 17
6.1. System Components ------------------------------------ 17
6.2. System Components Diagram ------------------------ 17
7 Operating Instructions ---------------------------------------- 17
7.1. System Capacity ----------------------------------------- 17
8 Test Mode ---------------------------------------------------------- 17
8.1. Utility--------------------------------------------------------- 17
9 Troubleshooting Guide---------------------------------------- 18
9.1. First checking --------------------------------------------- 18
9.2. Power Supply Unit & DC Power Circuit ------------ 19
9.3. DC Power Circuit ----------------------------------------- 20
9.4. FPGA-------------------------------------------------------- 21
9.5. COM Express module----------------------------------- 22
9.6. System log ------------------------------------------------- 23
9.7. DSP Card -------------------------------------------------- 24
9.8. FAN ---------------------------------------------------------- 25
9.9. SSD slot#1 ------------------------------------------------- 25
9.10. COM Express Module----------------------------------- 26
9.11. LANC#1, LANC#2, L2SW#1, L2SW#2 ------------- 27
9.12. Power Supply Unit --------------------------------------- 28
9.12.1. Total output voltage not output 1 ---------------- 28
9.12.2. Total output voltage not output 2 ---------------- 29
10 Disassembly and Assembly Instructions --------------- 30
10.1. Mother Board / CPU Board (COM Express
Module) ----------------------------------------------------- 30
10.1.1. Remove the Boards--------------------------------- 30
10.2. Fan and Power Supply Board------------------------- 33
11 Maintenance ------------------------------------------------------ 34
11.1. How To Replace a Flat Package IC ----------------- 34
11.1.1. Preparation-------------------------------------------- 34
11.1.2. Removal Procedure--------------------------------- 34
11.1.3. Procedure --------------------------------------------- 34
11.1.4. Removing Solder From Between Pins --------- 34
11.2. How to Replace the LLP (Leadless Leadframe
Package) IC and IC ground plate-------------------- 35
11.2.1. Preparation ------------------------------------------- 35
11.2.2. Caution ------------------------------------------------ 35
11.2.3. How to Remove the IC ---------------------------- 35
11.2.4. How to Install the IC -------------------------------- 35
11.2.5. How to Remove a Solder Bridge (Doesn't
apply to IC ground plate.) ------------------------- 36
11.3. Terminal Guide of the ICs, Transistors and
Diodes ------------------------------------------------------ 37
12 Schematic Diagram -------------------------------------------- 38
12.1. Mother Board --------------------------------------------- 38
12.1.1. No.1 (COM Express Connector) ---------------- 38
12.1.2. No.2 (SSD) ------------------------------------------- 39
12.1.3. No.3 (USB) ------------------------------------------- 40
12.1.4. No.4 (PCIe Buffer) ---------------------------------- 41
12.1.5. No.5 (RS232C) -------------------------------------- 42
12.1.6. No.6 (LED)-------------------------------------------- 43
12.1.7. No.7 (SW)--------------------------------------------- 44
12.1.8. No.8 (Ethernet Controler) ------------------------- 45
12.1.9. No.9 (L2SW#1) -------------------------------------- 46
12.1.10. No.10 (L2SW#2) ------------------------------------ 47
12.1.11. No.11 (FPGA Config) ------------------------------ 48
12.1.12. No.12 (FPGA Clock) ------------------------------- 49
12.1.13. No.13 (FPGA Bank3) ------------------------------ 50
12.1.14. No.14 (FPGA Bank4) ------------------------------ 51
12.1.15. No.15 (FPGA Bank5) ------------------------------ 52
12.1.16. No.16 (FPGA Bank6) ------------------------------ 53
12.1.17. No.17 (FPGA Bank7) ------------------------------ 54
12.1.18. No.18 (FPGA Bank8) ------------------------------ 55
12.1.19. No.19 (FPGA Power) ------------------------------ 56
12.1.20. No.20 (DSP IF) -------------------------------------- 57
12.1.21. No.21 (OPT IF) -------------------------------------- 58
12.1.22. No.22 (POWER_IN)-------------------------------- 59
12.1.23. No.23 (POWER_FAN_SSD) --------------------- 60
12.1.24. No.24 (POWER_FPGA)--------------------------- 61
12.1.25. No.25 (POWER_L2SW)--------------------------- 62
12.2. Power Supply Board ------------------------------------ 63
12.3. Waveform -------------------------------------------------- 65
12.3.1. DC-DC Converter Output Voltage -------------- 65
12.3.2. DC/DC Convertor Output Voltage Ripple
noise level -------------------------------------------- 65
12.3.3. Power On Reset signal ---------------------------- 66
12.3.4. Clock signal ------------------------------------------ 67
12.3.5. Alarm signal ------------------------------------------ 68
12.3.6. DSP control bus signal ---------------------------- 68
12.3.7. DSP TDM Highway bus signal ------------------ 69
12.3.8. FPGA Configuration ROM Interface ----------- 69
12.3.9. FPGA MOH Flash Interface ---------------------- 70
12.3.10. L2SW MDIO------------------------------------------ 71
12.3.11. L2SW RGMII ----------------------------------------- 71
12.3.12. Power Supply Board ------------------------------- 72
13 Printed Circuit Board------------------------------------------ 73
13.1. Mother Board --------------------------------------------- 73
13.1.1. Component View ------------------------------------ 73
13.1.2. Bottom View ------------------------------------------ 74
14 Appendix Information of Schematic Diagram -------- 75
15 Exploded View and Replacement Parts List----------- 76
3
KX-NSX1000/KX-NSX2000
15.1. IC and Connector Data----------------------------------76
15.1.1. IC17 (FPGA I/O Signal) ----------------------------76
15.1.2. IC15/16 (L2SW I/O Signal) ------------------------84
15.1.3. CN1 (COM Express Module Connector)-------87
15.1.4. CN3 (SSD#1 Connector) --------------------------89
15.1.5. CN4 (SSD#2 Connector) --------------------------90
15.1.6. CN9 (DSP#1 Connector) --------------------------91
15.1.7. CN8 (DSP#2 Connector) --------------------------93
15.1.8. CN14 (DSP#3 Connector) -------------------------95
15.1.9. Power Supply Unit I/F & FAN Connector ------96
15.2. Cabinet and Electric Parts------------------------------97
15.3. Accessories and Packing Materials------------------98
15.4. Replacement Parts List ---------------------------------99
15.4.1. Cabinet and Electrical Parts ----------------------99
15.4.2. Accessories and Packing Materials -------------99
15.4.3. Mother Board Parts-------------------------------- 100
15.4.4. Power Supply Board parts----------------------- 108
16 History ------------------------------------------------------------ 110
17 Appendix --------------------------------------------------------- 111
4
KX-NSX1000/KX-NSX2000
1 Safety Precautions
1. Before servicing, unplug the AC power cord to prevent an electric shock.
2. When replacing parts, use only the manufacturer's recommended components.
3. Check the condition of the power cord. Replace if wear or damage is evident.
4. After servicing, be sure to restore the lead dress, insulation barriers, insulation papers, shields, etc.
5. Before returning the serviced equipment to the customer, be sure to perform the following insulation resistance test to prevent
the customer from being exposed to shock hazards.
1.1.
For Service Technicians 
• Repair service shall be provided in accordance with repair technology information such as service manual so as to prevent fires,
injury or electric shock, which can be caused by improper repair work.
1. When repair services are provided, neither the products nor their parts or members shall be remodeled.
2. If a lead wire assembly is supplied as a repair part, the lead wire assembly shall be replaced.
3. FASTON terminals shall be plugged straight in and unplugged straight out.
• ICs and LSIs are vulnerable to static electricity.
When repairing, the following precautions will help prevent recurring malfunctions.
1. Cover plastic parts boxes with aluminum foil.
2. Ground the soldering irons.
3. Use a conductive mat on worktable.
4. Do not grasp IC or LSI pins with bare fingers.
1.2.
Insulation Resistance Test
1. Unplug the power cord and short the two prongs of the plug with a jumper wire.
2. Turn on the power switch.
3. Measure the resistance value with ohmmeter between the jumpered AC plug and each exposed metal cabinet part, such as
screw threads, control shafts, handle brackets, etc.
Note:
Some exposed parts may be isolated from the chassis by design. These will read infinity.
4. If the measurement is outside the specified limits, there is a possibility of shock hazard. The equipment should be repaired
and rechecked before it is returned to the customer.
Page of 127
Display

Panasonic KX-NSX1000 / KX-NSX2000 (serv.man2) Service Manual ▷ Download

  • DOWNLOAD Panasonic KX-NSX1000 / KX-NSX2000 (serv.man2) Service Manual ↓ Size: 9.94 MB | Pages: 127 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Panasonic KX-NSX1000 / KX-NSX2000 (serv.man2) in PDF for free, which will help you to disassemble, recover, fix and repair Panasonic KX-NSX1000 / KX-NSX2000 (serv.man2) PBX. Information contained in Panasonic KX-NSX1000 / KX-NSX2000 (serv.man2) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.