Panasonic KV-S7075C (serv.man2) Service Manual ▷ View online

49
8.2.13. Shield Plates 1, 2, 3, 4
(1) Remove the Flatbed Glass. (See 8.2.11.)
(2) Remove the 2 screws, and then remove the Shield Plate 4.
 
(3) Remove the 6 screws and 2 connectors (Flat cables), and
     then remove the Shield Plate 3.
 
Note 1: Caution when treating the flat cables
Pay attention to the flat cables so as not to be damaged
when disassembling and assembling them.
Note 2: Caution when treating the Transparent sheet
              (under the flat cables)
Be sure to fasten the one end of the Transparent sheet
with the Shield Plate 4.
50
(4) Remove the 2 screws (a) and 1 screw (b), and then remove
      the Shield Plate 2.
 
(5) Remove the 2 screws, and then remove the Shield Plate 1. 
Reassembling Note: Reassembling the Shield Plates 2 and 4 
 1. Be sure to reassemble the Shield Plates 2 and 4 so
     that the transparent sheet can be seen on the plates.
 2. Be sure to reassemble the Shield Plate 2 so that
     the plate securely comes into contact with the face
     of gasket on the Power Box.
51
8.2.14. CENTER Board
8.2.15. DRIVE Board
(1) Remove the Shield Plates 2 to 4. (See 8.2.13.) 
(2) Remove the Shield Plate 1. (See 8.2.13.)
(3) Remove the CONTROL Board. (See 8.2.8.)
(4) Remove the 5 flat cables and 3 connectors (CN2002,
     CN2005, CN2010) on the CENTER Board.
 
(5) Remove the 5 screws on the CENTER Board.
(1) Remove the Shield Plates 2 to 4. (See 8.2.13.)
 
(2) Disconnect the 2 flat cables and 7 connectors on the DRIVE
     Board.
(3) Remove the 6 screws on the DRIVE Board.
 
52
8.2.16. Carriage Motor
(1) Remove the Shield Plates 2 to 4. (See 8.2.13.)
(2) Remove the 4 screws and 1 connector on the DRIVE
     Board to release the Carriage Motor with the plate from
     the scanner. 
(3) Remove the 2 screws to separate the motor from the plate
      and belt.
 
Reassembling Note: 
a. Loosen the 3 screws and pull the Carriage Belt Support
    Plate in the direction of the arrow so as to reattach the
    Carriage Belt easily. Then, tighten the 3 screws to hold
    this position temporarily.
b. Reattach the Carriage Motor and belt to the original
    position, following the reverse order of disassembly.
c. Loosen the 3 screws again so that the belt tension
    increases on its own.
d. Tighten the 3 screws in order of [1], [2], and [3].
Page of 127