Panasonic KX-FLB853RU / KX-FA101A / KX-FA102A / KX-FA104E Service Manual ▷ View online
6.6.6.3. CALL SERVICE 3
"CALL SERVICE 3" means that the temperature of the fuser does not rise up to or exceed a constant temperature.
The temperature is monitored with the thermistor inside the fuser and detected with the voltage input into IC 604-21pin.
* When Call Service 3 is occurred, the cause can be distinguished by service mode
655.
Refer to P.114 for details.
CROSS REFERENCE:
ERROR MESSAGE (DISPLAY)(P.5)
117
KX-FLB853RU
6.6.6.4. CALL SERVICE 4
"CALL SERVICE 4" means that the FAN does not run or the running of the FAN cannot be detected normally.
The running of the FAN is detected by IC600-16 and 18pin. "CALL SERVICE 4" is displayed when it detects NG three times
continuously.
continuously.
After repairing, copy three times.If “CALL SERVICE 4 “ is displayed,check again.
118
KX-FLB853RU
CROSS REFERENCE:
ERROR MESSAGE (DISPLAY)(P.5)
119
KX-FLB853RU
6.6.6.5. CALL SERVICE 5
“CALL SERVICE 5” means that Main DC motor’s rotation detection signal (LD) does not become Low.
CROSS REFERENCE:
ERROR MESSAGE (DISPLAY)(P.5)
120
KX-FLB853RU
Click on the first or last page to see other KX-FLB853RU / KX-FA101A / KX-FA102A / KX-FA104E service manuals if exist.