37
7.2.3.
Error Code Table 3 (For BD)
7.2.4.
Error Code Table 3 (Power Supply & Digital Amplifier)
SELF
CHECK
Restoration operation
Since the power cord fell out during a power
failure or operation, it is under restoration
operation.
*It will OK, if a display disappears automati-
cally. If a display does not disappear, there is
the possibility that defective Digital P.C.B. /
DVD drive.
No display
PLEASE
WAIT
Unit is in termination process
Unit is in termination process now.
BYE
 is displayed and power will be turned off.
No display
UNFOR-
MAT
Unformatted disc error
You have inserted an unformatted DVD-RAM
or DVD-RW that is unformatted or recorded
on other equipment.
The disc is not 
formatted properly.
No PLAY
When there is a viewing restric-
tion on a BD-Video or DVD-
Video.
Rating password is set.
No display
Error Code
Diagnosis contents
Description
Monitor Display
Automatic FL display
SELF CHECK
PLEASE WAIT
UNFORMAT
No PLAY
The character indication flows
sideways.
Error
Code
F61
The abnormalities
In normal operation, when DCDET2 goes
Press [     STOP] on main
in an output or power
to "L" (Low) (Not during POWER OFF
unit for next error.
supply circuit of 
condition),  F61 appears on FLDisplay  
POWER AMP
Fan unit & its circuitries
for 1 second and PCONT goes to
 "L" (Low).This is due to speaker output
has DC voltage or fan is not working.
F76
F76
Abnormality in the 
In normal operation when DCDET1 is
Press [     STOP] on main
output voltage of 
detected "L" (Low) for two consecutive 
unit for next error.
stabilized power 
times, F76 is displayed on FL for 
supply
1 second and after that PCONT will be  
turned to "L" (Low). This is due to any of 
the DC voltages (+9V, +7V, -7V, +5V, 
+5.3V etc.) C22 not available.
Diagnosis Contents
Description of error
Automatic FL Display
Remarks
38
7.3.
Service Mode
Information necessary for service can be displayed.
Service mode setting:
1. Turn the power off.
2. Press the [5] [9] and [R] button simultaneously for five seconds, then [70 FRET] is displayed on FL.
3. Press the [
 ] or [
] button to select until [80 SRV] is displayed on FL.
4. Press the [OK] button.
5. It is displayed on FL as [SERV].: it is shown to have entered the service mode.
6. The command is transmitted by attached remote control
Method of making clear service mode: Press the power button (power off).
The display of information to each command is as follows.
NOTE:
       Do not use it excluding the designated command.
39
7.3.1.
Service Mode Table 1
When BD Mechanism is OK
When the drive is applicable drive.
When the drive is not applicable 
drive.
When BD Mechanism is NG
7.2. Self-Diagnos-
tic Functions Error code.
Checking whether the drive is applicable 
drive or not
Mechanism.
40
7.3.2.
Service Mode Table 2
Laser Used Time 
Indication
Check laser used time (hours) of BD 
Mechanism.
(******) is the used time display in 
hour.
1. Blu-ray Playback:
Laser used time of BD/DVD/CD in 
Playback/Recording mode is 
Counted.
Press [4] [1] in service mode.
Item
FL display
Key operation
Mode name
Description
(Remote controller key)
******
BP
****
2. Blu-ray Recordiing:
BR
****
3. DVD Playback:
DP
****
4. DVD Recording:
DR
****
5. CD:
CD
****
Page of 127
Display

Click on the first or last page to see other SA-BTT270EB / SA-BTT270EE / SA-BTT270EG / SA-BTT270EP / SA-BTT270GN / SC-BTT270EEK service manuals if exist.