11.3 System Installation 
11.3.1 Remote 
Controller 
Outline
 
A
B
C
D
G
F
E
 
 
 
 
 
 Name 
Function 
A:  Main screen 
Display information 
B:  Menu 
Open/Close main menu 
C:  Triangle (Move) 
Select or change item 
D: Operate 
Start/Stop 
operation 
E:  Back 
Back to previous item 
F:  Quick Menu 
Open/Close Quick menu 
G: OK 
Confirm 
 
 
24
40˚c
10:34am, Mon
18˚c
5
6
4
3
2
1
˚c
 
 
 
Name 
 
 
 
 
    
1:  Function icon 
Display set function/status 
 
 
  Holiday mode 
Demand 
control     
 
 
  Weekly timer 
Back-up 
heater     
 
 
  Quiet mode 
Booster 
heater     
 
 
 
Remote controller room 
thermo 
  Solar 
    
 
 
  Powerful mode 
Boiler 
    
2:  Mode 
Display set mode/current status of mode 
 
 
 
Heating 
Cooling 
    
 
 
 
Auto 
 
Hot water supply 
Auto heating 
Auto cooling 
 
 
 
Heap pump operating 
 
 
 
 
 
 
3: Temp 
setting 
  Set room temp 
Compensation curve 
Set direct water 
temp 
  Set ppol temp 
4:  Display Heat tank  Display current heating temperature (it is set temperature when enclosed by line) 
5:  Display tank temp  Display current tank temperature (it is set temperature when enclosed by line) 
6:  Outdoor temp 
Display outdoor temp 
 
 
 
 
82 
First time of power ON (Start of installation) 
Initialization
12:00, Mon
Initializing.
When power is ON, firstly initialization
screen appears (10 sec)
17:26, Wed
Start
When initialization screen ends, it turns
to normal screen.
Language
12:00, Wed
ENGLISH
FRANCAIS
DEUTSCH
ITALIANO
Select
Confirm
When any button is pressed, language
setting screen appears.
(CAUTION) If initial setting is not
performed, it does not go into menu.
Set language & confirm
Clock format
12:00, Mon
24h
am/pm
Select
Confirm
When language is set, setting screen of
time display appears (24h/am/pm)
Set time display & confirm
Date & time
12:00, Mon
Year/Month/DayHour : Min
2015
 / 01 / 01
12  :  00
Select
Confirm
YY/MM/DD/Time setup screen appears
Set YY/MM/DD/Time & confirm
17:26, Wed
Start
Back to initial screen
Press menu, select Installer setup
Main Menu
17:26, Wed
System check
Personal setup
Service contact
Installer setup
Select
Confirm
Confirm to go into Installer setup
 
 
 
 
 
 
 
 
 
 
83 
11.3.2 Installer 
Setup 
1
System setup
Optional PCB connectivity
Yes/No
2
Only when the selection for optional PCB is Yes
Zone & Sensor
1 Zone/2 Zone
 Zone settings
3
Heater capacity
Capacity select
4
Anti freezing
Yes/No
5
Tank connection
6
Only when the selection for optional PCB is Yes
Buffer Tank connection
7
Only when the selection for Tank connection is Yes
Tank heater
External/Internal
 Heater ON time setup
8
Base pan heater
Yes/No
 A / B
9
Alternative outdoor sensor
Yes/No
10
Bivalent connection
Yes/No
 Bivalent setup
11
External SW
12
Only when the selection for optional PCB is Yes
Solar connection
13
Only when the selection for optional PCB is Yes
External Error signal
14
Only when the selection for optional PCB is Yes
Demand control
15
Only when the selection for optional PCB is Yes
SG ready
16
Only when the selection for optional PCB is Yes
External Compressor SW
Yes/No
17
Circulation liquid
18
Only when the selection for optional PCB is Yes
Heat-Cool SW
Yes/No
19
Force Heater
Auto/Manual
Yes/No
Yes/No
∆T setup
Yes/No
Yes/No
 Tank setup
 Solar setup
Yes/No
Yes/No
Yes/No
 Capacity setup
Water/glycol
 
 
84 
20
Operation setup
Heat
Water temp. for heating ON
Compensation curve
Compensation
curve setup
Cooling model only
21
Direct
Direct temp. setup
Outdoor temp. for heating OFF
Heating OFF Temp. setup
22
∆T for heating ON
∆T for heating setup
23
Outdoor temp. for heater ON
O/D temp for heater ON setup
24
(Display only if Cool exist, or else skip)
Cool
Water temp. for cooling ON
Compensation curve
Compensation
curve setup
Cooling model only
25
Direct
Direct temp. setup
∆T for Cooling ON
∆T for cooling setup
26
Auto
Outdoor temp. for
(Heat to Cool)
Heat
 Cool change temp. setup
27
Outdoor temp. for
(Cool to Heat)
Cool
 Heat change temp. setup
28
Tank
Floor operation time (max.)
Max. operation time for Heat & Cool mode setup
29
Tank heat up time (max.)
Max. operation time for Tank mode setup
30
Tank re-heat temp.
Tank re-heat temp. setup
31
Sterilization
Sterilization day and temp. and time setup
32
Service setup
Pump maximum speed
Pump maximum speed setup
 Air purge
33
Pump down
Pump down ON / OFF
34
Dry concrete
ON (Dry concrete)
35
Edit (Dry concrete schedule)
 Day and temp. setup
Service contact
Contact 1
 Name and Tel No. setup
Contact 2
 Name and Tel No. setup
Only when the
selection for Tank
is Yes
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 