DOWNLOAD Panasonic S-22KA1E5 / S-28KA1E5 / S-36KA1E5 / S-45KA1E5 / S-56KA1E5 / S-63KA1E5 / S-71KA1E5 / S-22YA1E5 / S-28YA1E5 / S-36YA1E5 / S-45YA1E5 / S-56YA1E5 / S-22NA1E5 / S-28NA1E5 / S-32NA1E5 / S-36NA1E5 / S-45NA1E5 / S-56NA1E5 / S-45MA1E5 / S-56MA1E5 / S-63MA1E5 / S-7 Service Manual ↓ Size: 16.42 MB | Pages: 127 in PDF or view online for FREE

Model
S-22KA1E5 S-28KA1E5 S-36KA1E5 S-45KA1E5 S-56KA1E5 S-63KA1E5 S-71KA1E5 S-22YA1E5 S-28YA1E5 S-36YA1E5 S-45YA1E5 S-56YA1E5 S-22NA1E5 S-28NA1E5 S-32NA1E5 S-36NA1E5 S-45NA1E5 S-56NA1E5 S-45MA1E5 S-56MA1E5 S-63MA1E5 S-7
Pages
127
Size
16.42 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
s-22ka1e5-s-28ka1e5-s-36ka1e5-s-45ka1e5-s-56ka1e5-.pdf
Date

Panasonic S-22KA1E5 / S-28KA1E5 / S-36KA1E5 / S-45KA1E5 / S-56KA1E5 / S-63KA1E5 / S-71KA1E5 / S-22YA1E5 / S-28YA1E5 / S-36YA1E5 / S-45YA1E5 / S-56YA1E5 / S-22NA1E5 / S-28NA1E5 / S-32NA1E5 / S-36NA1E5 / S-45NA1E5 / S-56NA1E5 / S-45MA1E5 / S-56MA1E5 / S-63MA1E5 / S-7 Service Manual ▷ View online

105 
Note 
Ɣ
   Thoroughly study the following installation locations 
1.  In such places as restaurants and kitchens, considerable amount of oil steam and flour adhere to the turbo 
fan, the fin of the heat exchanger and the drain pump, resulting in heat exchange reduction, spraying, 
dispersing of water drops, drain pump malfunction, etc.  
In these cases, take the following actions: 
x  Make sure that the ventilation fan for smoke-collecting hood on a cooking table has sufficient capacity so that 
it draws oily steam which should not flow into the suction of the air conditioner. 
x  Make enough distance from the cooking room to install the air conditioner in such place where it may not 
suck in oily steam. 
 
Air conditioner
Cooking table
Ensure ample
distance
 
 
2.  Avoid installing the air conditioner in such circumstances where cutting oil mist or iron powder exist 
especially in factories, etc. 
3.  Avoid places where inflammable gas is generated, flows-in, contaminated, or leaked. 
4.  Avoid places where sulphurous acid gas or corrosive gas can be generated. 
5.  Avoid places near high frequency generators. 
 
Model name 
Height from the ceiling 
S-63UA1E5 S-71UA1E5 
S-90UA1E5  
246mm or more 
11.6.3 
INSTALLATION OF INDOOR UNIT 
CEILING OPENING DIMENSIONS AND HANGING BOLT LOCATION 
 
The paper model for installation expand or shrink 
according to temperature and humidity.  
Check on dimensions before using it. 
Caution 
During the installation, care must be taken not to 
damage electric wires. 
x  The dimensions of the paper model for installation 
are the same as those of the ceiling opening 
dimensions. 
x  Be sure to discuss the ceiling drilling work with the 
workers concerned. 
 
This air conditioner uses a drain up motor. 
Horizontally install the unit using a level gauge. 
(Hanging bolt)
D rain pipe
(Unit: mm)
880 (
C
ei
lin
op
eni
ng
)
795 (
H
an
gi
ng
 bol
t)
840 (
U
ni
t si
ze)
840 (U nit size)
R efrigerant pipe
700
0
9
0
9
42.
5
42
.5
880 (Ceiling opening)
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
106 
POSITIONS OF AIR CONDITIONER BODY AND CEILING SURFACE 
 
Flat washer for M10 (accessory)
Nut
(W3/8 or M10)
Flat washer for M10 (accessory)
Hanging bolt
(W3/8 or M10)
Nut
(W3/8 or M10)
M10 Spring washer
 
 
Warning
  Tighten the nut and bolt to prevent unit from falling
 
HANGING POSITION OF THE AIR CONDITIONER BODY 
 
Air conditioner body gap setting 
between ceiling surface should 
be 10mm as right figure. 
(Adjustment of height direction 
should be done after fixing 
decorative panel.) 
Air
conditioner
Keep the length of the bolt
from the bracket as 40 mm
Ceiling
Ceiling
Paper model for
installation
Place the screws for paper model
(4 pieces)
10
m
m
Open the ceiling board along the
outer edge of the paper model
 
 
11.6.4 REFRIGERANT 
PIPING 
Refrigerant is charged to the outdoor unit. For details, see the manual for installation work of outdoor unit. (Additional 
charging, etc.) 
 
1. 
Brazing for piping. 
a.  Execute brazing before tightening the flare nut. 
b.  Brazing must be executed while blowing 
nitrogen gas. (This prevents generation of 
oxidized scale in copper pipe.) 
2. 
When there is a lot of brazings for long piping, 
install a strainer midway of the piping. (The 
strainer is locally supplied.) 
3. 
Use clean copper pipe with inner wall surface 
free from mist and dust. Blow nitrogen gas or air 
to blow off dust in the pipe before connection. 
4. 
Form the piping according to its routing. Avoid 
bending and bending back the same piping point 
more than three times. (This will result in 
hardening of the pipe). 
5. 
After deforming the pipe, align centers of the 
union fitting of the indoor unit and the piping, and 
tighten them firmly with wrenches. 
6. 
Connect pipe to the service valve in the outdoor 
unit. 
7. 
After completed the piping connection, be sure to 
check if there is gas leakage in indoor and 
outdoor connection. 
 
Union
round mark
 
 
x  Confirm the round mark of the union (thin side) is 
always at lower direction after connecting piping. 
 
 
 
 
Vacuum drying 
After completing the piping connection, execute vacuum drying for the connecting piping and the indoor unit. 
The vacuum drying must be carried out by using the service ports of both the liquid and gas side valves. 
 
CAUTION   Use two wrenches and tighten with regular torque. 
Flare nut fastening torque N•m (kgf•cm) 
 
Cooling capacity 
Liquid piping 
Gas side piping 
ø6.35 18 
(180) ø12.7 55 
(560) 
 
2.2kW 
6.3kW  ø6.35mm 
ø12.7mm 
ø9.52 
42 (430) 
ø15.88 
65 (660) 
 
7.1kW or more 
ø9.52mm 
ø15.88mm 
 
 
107 
11.6.5 
INDOOR UNIT DRAIN PIPING 
x  Drain piping must have down-slope (1/50 to 
1/100); be sure not to provide up-and-down slope 
to prevent reversal flow. 
x  During drain piping connection, be careful not to 
exert extra force on the drain port at the indoor 
unit. 
x  The outside diameter of the drain connection at 
the indoor unit is 32 mm. 
Piping material: Polyvinyl chloride pipe VP-25 and 
pipe fittings.
 
x  Be sure to perform heat insulation on the drain 
piping. 
Heat insulation material: Polyethylene foam with 
thickness more than 8 mm (local supply).
 
 
 
Upward routing
Pipe clamp
Indoor
unit
Trap
Down-slope
 
 
x  The height of drain may be possible up to 750 mm. 
 
 
Down-slope (1/50 ~ 1/100)
Drain port
750 m
m
 or
 les
s
Indoor unit
Elbow
Elbow
 
 
x  When drain set piping, install as shown in the 
figure below. 
 
Drain Test 
The air conditioner uses a drain up motor to drain water. Use the following procedure to test the drain up motor 
operation. 
x  Connect the main drain pipe to exterior and leave 
it provisionally until the test comes to an end. 
x  Feed water to the flexible drain hose and check 
the piping for leakage. 
x  Be sure to check the drain up motor for normal 
operating and noise when electric wiring is 
complete. 
x  When the test is complete, connect the flexible 
drain hose to the drain port. 
Feed water
Drain hose
Drain up motor
Glue the joint
Drain hose connection
Use the clip (accessory)
Main drain
pipe
Drain
port
11.6.6 HEAT 
INSULATION 
Caution
 
Be sure to perform heat insulation on the drain, liquid and gas piping. Imperfection in heat insulation work leads to water 
leakage. 
 
1.  Use the heat insulation material for the refrigerant piping which has an excellent heat-resistance (over 120°C). 
 
Overlap with heat
insulator for piping.
Indoor
unit
Band
(Accessory)
Heat insulator
for piping
(Local supply)
Heat insulator
(Accessory)
Hose clip (Accessory)
Heat insulator (Local
supply) (The thickness
must be at least 8 mm.)
Flexible hose with
heat insulator
(Accessory)
PVC pipe
(O.D. ø25)
(Local supply)
To be glued
It may be required to take off this part for checking
or servicing the drain up motor. Please do not glue.
Make sure that there is no clearance here.
 
 
 
 
 
108 
2.  Precautions in high humidity circumstance. 
This air conditioner has been tested according to the “JIS Standard Conditions with Mist” and have been 
confirmed that there are no faults. However, if it is operated for a long time in high humid atmosphere (dew point 
temperature: more than 23°C), water drops are liable to fall. In this case, add heat insulation material according to 
the following procedure: 
Heat insulation material to be prepared… 
Adiabatic glass wool with thickness 10 to 20 
mm. 
Stick glass wool on all air conditioners that are 
located in ceiling atmosphere. 
In addition to the normal heat insulation 
(thickness: more than 8 mm) for refrigerant 
piping (gas piping: thick piping) and drain 
piping, add a further of 10 mm to 30 mm 
thickness material. 
 
Pipe down
Indoor
unit
Pipe
Putty
Trap
Incision
Drain pipe
 
 
ސ  Put the incision at the trap part of the heat insulator 
(for water drain)
Wall seal 
x  When the outdoor unit is installed on a higher position than the indoor unit, install the trap so as not to instill 
rain water into the wall by transmitting in piping. 
x  Stuff the space among piping, the electric wire, and the drain hose with “Putty” and seal the penetration wall 
hole. 
Make sure that rain water do not instill into the wall. 
11.6.7 ELECTRICAL 
WIRING 
As to main power source and cable size of outdoor unit, read the installation manual attached to the outdoor unit. 
 
Warning
 
The units must be installed in accordance with applicable national and local regulations. 
The units installed by a professional installer must be supplied from a dedicated electrical circuit. 
All electric work must be carried out by a qualified technician according to proper technical standards for electrical work and 
according to installation manual for installation work. 
If circuits with insufficient capacity are used, or if electrical work is not carried out properly, electric shocks or fire may result. 
Caution
Be sure to install a current leakage breaker or circuit breaker to the main power supply, otherwise electric shocks may result. 
Caution
Be sure to connect the unit to secure earth connection. (with a earth resistance of 100 
ȍ or less). 
If the earthing work is not carried out properly, electric shocks may result. 
Warning
Wiring shall be connected securely using specified cables and fix them securely so that external force of the cables may not 
transfer to the terminal connection section. Imperfect connection and fixing leads to fire, etc. 
 
1.  Select a power source that is capable of supplying the current required by the air conditioner. 
2.  Feed the power source to the unit via a distribution switch board designed for this purpose, the switch should 
disconnected all poles with a contact separation of at least 3 mm. 
3.  Always ground the air conditioner with a grounding wire and screw to meet the LOCAL REGULATIONS. 
4.  Be sure to connect the wires correctly to terminal board with connecting the crimp type ring terminal to the wires. 
5.  Be sure to turn off the main power before installing and connecting the remote controller. 
 
Note
If momentarily turning on the power supply for both the indoor and outdoor units, do not turn the power off after at least 1 
minute has passed. (For the system’s automatic setting.) 
Turning off the power supply on the way may cause an abnormal operation. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 127
Display

Click on the first or last page to see other S-22KA1E5 / S-28KA1E5 / S-36KA1E5 / S-45KA1E5 / S-56KA1E5 / S-63KA1E5 / S-71KA1E5 / S-22YA1E5 / S-28YA1E5 / S-36YA1E5 / S-45YA1E5 / S-56YA1E5 / S-22NA1E5 / S-28NA1E5 / S-32NA1E5 / S-36NA1E5 / S-45NA1E5 / S-56NA1E5 / S-45MA1E5 / S-56MA1E5 / S-63MA1E5 / S-7 service manuals if exist.