DOWNLOAD Panasonic S-22KA1E5 / S-28KA1E5 / S-36KA1E5 / S-45KA1E5 / S-56KA1E5 / S-63KA1E5 / S-71KA1E5 / S-22YA1E5 / S-28YA1E5 / S-36YA1E5 / S-45YA1E5 / S-56YA1E5 / S-22NA1E5 / S-28NA1E5 / S-32NA1E5 / S-36NA1E5 / S-45NA1E5 / S-56NA1E5 / S-45MA1E5 / S-56MA1E5 / S-63MA1E5 / S-7 Service Manual ↓ Size: 16.42 MB | Pages: 127 in PDF or view online for FREE

Model
S-22KA1E5 S-28KA1E5 S-36KA1E5 S-45KA1E5 S-56KA1E5 S-63KA1E5 S-71KA1E5 S-22YA1E5 S-28YA1E5 S-36YA1E5 S-45YA1E5 S-56YA1E5 S-22NA1E5 S-28NA1E5 S-32NA1E5 S-36NA1E5 S-45NA1E5 S-56NA1E5 S-45MA1E5 S-56MA1E5 S-63MA1E5 S-7
Pages
127
Size
16.42 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
s-22ka1e5-s-28ka1e5-s-36ka1e5-s-45ka1e5-s-56ka1e5-.pdf
Date

Panasonic S-22KA1E5 / S-28KA1E5 / S-36KA1E5 / S-45KA1E5 / S-56KA1E5 / S-63KA1E5 / S-71KA1E5 / S-22YA1E5 / S-28YA1E5 / S-36YA1E5 / S-45YA1E5 / S-56YA1E5 / S-22NA1E5 / S-28NA1E5 / S-32NA1E5 / S-36NA1E5 / S-45NA1E5 / S-56NA1E5 / S-45MA1E5 / S-56MA1E5 / S-63MA1E5 / S-7 Service Manual ▷ View online

85 
2.  Drill the piping plate hole with ø70mm hole-core drill. 
x  Line according to the left and right side of the installation plate. The meeting point of the extended line is the 
center of the hole. Another method is by putting measuring tape at position as shown in the diagram above. 
The hole center is obtained by measuring the distance namely 128 mm for left and right hole respectively. 
x  Drill the piping plate hole at either the right or the left and the hole should be slightly slanted to the outdoor 
side. 
 
TO DRILLA HOLE IN THE WALL AND INSTALL A SLEEVE OF PIPING 
 
1.  Insert the piping sleeve to the hole. 
2.  Fix the bushing to the sleeve. 
3.  Cut the sleeve until it extrudes about 15 mm from 
the wall. 
 
 
When the wall is hollow, please be sure to use the sleeve
for tube assembly to prevent dangers caused by mice biting
the connecting cable.
CAUTION
 
 
4.  Finish by sealing the sleeve with putty or caulking 
compound at the final stage. 
 
15 mm
Putty or caulking compound
ø70 through hole
Indoor
Outdoor
Sleeve for
tube
assembly
Approx. 5 - 7 mm
Bushing for tube assembly
Wall
INDOOR UNIT INSTALLATION 
 
Use shock absorber during
pull out the piping to protect
the intake grille from damage
Piping
Intake grille
Shock absorber
Piping
Do not turn over the unit without it’s shock
absorber during pull out the piping. It may
cause intake grille damage.
CAUTION
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
86 
Pull out the Indoor piping
1. FOR THE RIGHT REAR PIPING
Step-1
Install the Indoor Unit
Step-2
Secure the Indoor Unit
Step-3
Insert the connecting cable
Step-4
 
 
2. FOR THE RIGHT AND RIGHT BOTTOM PIPING
Install the Indoor Unit
Step-2
Insert the connecting cable
Step-3
Secure the Indoor Unit
Step-4
Step-1
Pull out the Indoor piping
 
 
3. FOR THE EMBEDDED PIPING
Replace the drain hose
Step-1
• Use a spring bender or equivalent to bend the
piping so that the piping is not crushed.
Bend the embedded piping
Cut and flare the embedded piping
Pull the connecting cable into Indoor Unit
• The inside and outside connecting cable can
be connected without removing the front grille.
Step-2
Step-3
Step-4
• When determining the dimensions of the piping,
slide the unit all the way to the left on the
installation plate.
Install the Indoor Unit
Step-5
• Please refer to “REFRIGERANT PIPING” column.
Connect the piping
• Please carry out insulation at pipe connection
portion as mentioned in Indoor/Outdoor unit
installation diagram.
• If drain hose or connecting piping is in the room
(where dew may form), please increase the
insulation by using POLY-E FOAM with tickness
6mm or above.
Insulate and finish the piping
Step-6
Step-7
Secure the Indoor Unit
Step-8
 
 
Install the indoor unit
Right and Right Bottom piping
Cover for the
bottom piping
Tape it with piping in a
position as mentione d
in Fig. below.
Cover for
the right
piping
Piping
Drain hose
Right Rear piping
Cover for the
bottom piping
Cover for the
bottom piping
Tape it with
piping in a position a s
mentioned in
Fig. below.
Cover for
the right
piping
Piping
Drain
hose
Cover for the left piping
Cover for piping
In case of the cover is cut, keep the cover at the rear
of chassis as shown in the illustration for future
reinstallation.
(Left, right and 2 bottom covers for piping.)
Hook the indoor unit onto the upper portion
of installation plate. (Engage the indoor
unit with the upper edge of the installation
plate). Ensure the hooks are properly
seated on the installation plate by moving
it in left and right.
Drain hose
Sleeve for
piping hole
Indoor unit
Hooks at
installation
plate
Piping
Secure the Indoor Unit
1. Press the lower left and right side of the
unit against the installation plate until
hooks engages with their slot (sound click).
Installation
plate
Unit’s
hook
To take out the unit, push the
marking
at the bottom unit, and pull it slightly towards
you to disengage the hooks from the unit.
PUSH
PUSH
Cover for the left piping
How to keep the cover
g
n
i
k
r
a
m
Ab
ou
t
7
– 8
 cm
Connecting
cable
Gas side
piping
Liquid side
piping
Insert the connecting cable
(This can be used for left rear piping and bottom piping also.)
Guide
surface
Connecting cable
Drain hose
87 
Drain cap
Drain hose
Adjustthe piping slightlydownwards.
How to pull the piping and drain hose out, in case of the embedded piping
.
PVC tube
for drain
hose
Indoor unit
72 mm
Piping
Cable
Apply putty or
caulking material
to seal the wall
opening.
Connecting
cable
Piping
More
than
470
 mm
Mo
re 
than
1150
mm
PVC tube (VP-65) for piping
and connecting cable
PVC tube for drain hose (VP-30)
PVC tube for
drain hose (VP-20)
M
o
re
 t
han 7
00 m
m
In case of left piping how to insert the
connecting cable and drain hose.
Cable
45
°
Drain
hose
Piping
Drain hose
from main unit
(For the right piping, follow the same procedure)
Sleeve for piping hole
Drain hose
Piping
Connecting
cable
More than 1150 mm
Rear view forleft piping installation
Replace the drain hose
Connecting cable
Drain hose
11.4.4 REFRIGERANT 
PIPING 
Refrigerant is charged to the outdoor unit. For details, see the manual for installation work of outdoor unit. (Additional 
charging, etc.) 
 
1.  Brazing for piping. 
a.  Execute brazing before tightening the flare nut. 
b.  Brazing must be executed while blowing 
nitrogen gas. (This prevents generation of 
oxidized scale in copper pipe.) 
2.  When there is a lot of brazings for long piping, 
install a strainer midway of the piping. (The strainer 
is locally supplied.) 
3.  Use clean copper pipe with inner wall surface free 
from mist and dust. Blow nitrogen gas or air to 
blow off dust in the pipe before connection. 
4.  Form the piping according to its routing. Avoid 
bending and bending back the same piping point 
more than three times. (This will result in hardening 
of the pipe). 
5.  After deforming the pipe, align centers of the union 
fitting of the indoor unit and the piping, and tighten 
them firmly with wrenches. 
6.  Connect pipe to the service valve or ball valve 
which is located below the outdoor unit. 
7.  After completed the piping connection, be sure to 
check if there is gas leakage in indoor and outdoor 
connection. 
 
Union
 
 
Vacuum drying 
After completing the piping connection, execute vacuum drying for the connecting piping and the indoor unit. 
The vacuum drying must be carried out by using the service ports of both the liquid and gas side valves. 
 
CAUTION   Use two wrenches and tighten with regular torque. 
Flare nut fastening torque N•m (kgf•cm) 
 
Cooling capacity 
Liquid piping 
Gas side piping 
ø6.35mm 18 
(180) ø12.7mm 55 
(560)  2.2kW 
6.3kW 
ø6.35mm 
ø12.7mm 
ø9.52mm 
42 (430) 
ø15.88mm 
65 (660) 
 
7.1kW or more 
ø9.52mm 
ø15.88mm 
 
 
 
 
 
 
 
 
 
88 
11.4.5 ELECTRICAL 
WIRING 
As to main power source and cable size of outdoor unit, read the installation manual attached to the outdoor unit. 
 
Warning
 
The units must be installed in accordance with applicable national and local regulations. 
The units installed by a professional installer must be supplied from a dedicated electrical circuit. 
All electric work must be carried out by a qualified technician according to proper technical standards for electrical work and 
according to installation manual for installation work. 
If circuits with insufficient capacity are used, or if electrical work is not carried out properly, electric shocks or fire may result. 
Caution
Be sure to install a current leakage breaker or circuit breaker to the main power supply, otherwise electric shocks may result. 
Caution
Be sure to connect the unit to secure earth connection. (with a earth resistance of 100 
ȍ or less). 
If the earthing work is not carried out properly, electric shocks may result. 
Warning
Wiring shall be connected securely using specified cables and fix them securely so that external force of the cables may not 
transfer to the terminal connection section. Imperfect connection and fixing leads to fire, etc. 
 
1.  Select a power source that is capable of supplying the current required by the air conditioner. 
2.  Feed the power source to the unit via a distribution switch board designed for this purpose, the switch should 
disconnected all poles with a contact separation of at least 3 mm. 
3.  Always ground the air conditioner with a grounding wire and screw to meet the LOCAL REGULATIONS. 
4.  Be sure to connect the wires correctly to terminal board with connecting the crimp type ring terminal to the wires. 
5.  Be sure to turn off the main power before installing and connecting the remote controller. 
 
Note
If momentarily turning on the power supply for both the indoor and outdoor units, do not turn the power off after at least 1 
minute has passed. (For the system’s automatic setting.) 
Turning off the power supply on the way may cause an abnormal operation. 
 
x  Use the standard power cord for Europe (such as H05RN-F or H07RN-F which conforms to CENELEC (HAR) 
rating specifications) or use the cables based on IEC standard. (245IEC57, 245IEC66) 
 
Outdoor unit
Branch pipe
Refrigerant pipe
Control cable
To other indoor unit
Indoor unit-A
Wired controller
Earth
Earth
Switch
Infrared remote controller
Receiver
Earth leakage breaker
Power supply
(ex. 1 ~ 230V)
Switch
Power supply
(ex. 1 ~ 230V)
Provide separate power supplies to the indoor and outdoor units.
Earth leakage breaker
 
 
x  Power supply specifications 
 
Power supply cable 
Circuit breaker 
(Minimum capacity) 
 
Model 
name 
Power 
supply 
Minimum power 
cable supply 
cables 
 
 1 
Length 
(m) 
 
Leakage 
current 
breaker 
(A) 
Switch 
(A) 
Fuse 
(A) 
 2 
Control 
Cable 
 
Remote 
Controller 
Cable 
 
Indoor unit 
220V-240V~ 
2 mm
2
 100  15A  15A  15A 
0.75 
mm
2
 
0.5 ~ 2 mm
2
 
 1. The maximum length shows a 2% voltage drop. 
 2. Use an unshielded bus transmission line. 
 
 
 
 
 
 
 
Page of 127
Display

Click on the first or last page to see other S-22KA1E5 / S-28KA1E5 / S-36KA1E5 / S-45KA1E5 / S-56KA1E5 / S-63KA1E5 / S-71KA1E5 / S-22YA1E5 / S-28YA1E5 / S-36YA1E5 / S-45YA1E5 / S-56YA1E5 / S-22NA1E5 / S-28NA1E5 / S-32NA1E5 / S-36NA1E5 / S-45NA1E5 / S-56NA1E5 / S-45MA1E5 / S-56MA1E5 / S-63MA1E5 / S-7 service manuals if exist.