DOWNLOAD Panasonic CS-Z20TKEW / CS-Z25TKEW / CS-Z35TKEW / CS-Z42TKEW / CS-Z50TKEW / CS-Z71TKEW / CS-XZ20TKEW / CS-XZ25TKEW / CS-XZ35TKEW / CS-XZ50TKEW / CU-Z20TKE / CU-Z25TKE / CU- / 35TKE / CU-Z42TKE / CU-Z50TKE / CU-Z71TKE / CU-Z20TKE / CU-Z25TKE / CU-Z35TKE / CU-Z50TKE Service Manual ↓ Size: 33.93 MB | Pages: 127 in PDF or view online for FREE

Model
CS-Z20TKEW CS-Z25TKEW CS-Z35TKEW CS-Z42TKEW CS-Z50TKEW CS-Z71TKEW CS-XZ20TKEW CS-XZ25TKEW CS-XZ35TKEW CS-XZ50TKEW CU-Z20TKE CU-Z25TKE CU- 35TKE CU-Z42TKE CU-Z50TKE CU-Z71TKE CU-Z20TKE CU-Z25TKE CU-Z35TKE CU-Z50TKE
Pages
127
Size
33.93 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-z20tkew-cs-z25tkew-cs-z35tkew-cs-z42tkew-cs-z50.pdf
Date

Panasonic CS-Z20TKEW / CS-Z25TKEW / CS-Z35TKEW / CS-Z42TKEW / CS-Z50TKEW / CS-Z71TKEW / CS-XZ20TKEW / CS-XZ25TKEW / CS-XZ35TKEW / CS-XZ50TKEW / CU-Z20TKE / CU-Z25TKE / CU- / 35TKE / CU-Z42TKE / CU-Z50TKE / CU-Z71TKE / CU-Z20TKE / CU-Z25TKE / CU-Z35TKE / CU-Z50TKE Service Manual ▷ View online

105 
16.3.4  Low Temperature Compressor Oil Return Control 
  In heating operation, if the outdoor temperature falls below -10°C when compressor starts, the compressor 
frequency will be regulated up to 600 seconds. 
 
16.3.5  Cold Draught Prevention Control 
  When indoor pipe temperature is low, cold draught operation starts where indoor fan speed will be reduced. 
 
16.3.6 Deice 
Operation 
  When outdoor pipe temperature and outdoor air temperature is low, deice operation start where indoor fan motor 
and outdoor fan motor stop and operation LED blinks. 
 
16.3.7  Low Pressure Protection Control 
  During low ambient heating operation, if the pipe temperature drops below -24°C, the max frequency will be 
reduced and limited. 
  If it does not rises after 3 minutes, the compressor will stop. 
  The compressor will start again if the pipe temperature rises above -20°C. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
106 
17. Servicing 
Mode 
17.1  Auto OFF/ON Button 
 
 
 
1  AUTO OPERATION MODE 
The Auto operation will be activated immediately once the Auto OFF/ON button is pressed. This operation 
can be used to operate air conditioner with limited function if remote control is misplaced or malfunction. 
 
2  TEST RUN OPERATION (FOR PUMP DOWN/SERVICING PURPOSE) 
The Test Run operation will be activated if the Auto OFF/ON button is pressed continuously for more than 
5 seconds. A “beep” sound will heard at the fifth seconds, in order to identify the starting of Test Run 
operation (Forced cooling operation). Within 5 minutes after Forced cooling operation start, the Auto OFF/ON 
button is pressed for more than 5 seconds. A 2 “beep” sounds will heard at the fifth seconds, in order to 
identify the starting of Forced heating operation. 
 
The Auto OFF/ON button may be used together with remote control to set / change the advance setting of air 
conditioner operation. 
 
Auto Operation 
Test Run Operation 
(Forced Cooling Operation)
Test Run Operation 
(Forced Cooling Operation)
Remote Control Number 
Switch Mode 
Remote Control Receiving
Sound OFF/ON  
Auto OFF/ON button
pressed 
Beep x 4 
Beep x 3
Beep    Beep 
5 sec
8 sec
11 sec
16 sec
Main unit always continue Test Run (forced cooling) operation.  
Press “AC RESET” 
at remote control
Press “AC RESET”, then any 
key at remote control  
Press “AC RESET” 
at remote control 
 
 
3  REMOTE CONTROL NUMBER SWITCH MODE 
The Remote Control Number Switch Mode will be activated if the Auto OFF/ON button is pressed 
continuously for more than 11 seconds (3 “beep” sounds will occur at 11th seconds to identify the Remote 
Control Number Switch Mode is in standby condition) and press “AC RESET” button and then press any 
button at remote control to transmit and store the desired transmission code to the EEPROM. 
 
There are 4 types of remote control transmission code could be selected and stored in EEPROM of indoor 
unit. The indoor unit will only operate when received signal with same transmission code from remote control. 
This could prevent signal interference when there are 2 or more indoor units installed nearby together. 
To change remote control transmission code, short or open jumpers at the remote control printed circuit 
board. 
 
JB
JA
 
Remote Control Printed Circuit Board 
Jumper A (J-A) 
Jumper B (J-B) 
Remote Control No. 
Short Open 
(Default) 
Open Open  B 
Short Short  C 
Open Short  D 
 
  During Remote Control Number Switch Mode, press any button at remote control to transmit and store 
the transmission code to the EEPROM. 
 
 
 
 
107 
4  REMOTE CONTROL RECEIVING SOUND OFF/ON MODE 
The Remote Control Receiving Sound OFF/ON Mode will be activated if the Auto OFF/ON button is pressed 
continuously for more than 16 seconds (4 “beep” sounds will occur at 16th seconds to identify the Remote 
Control Receiving Sound Off/On Mode is in standby condition) and press “AC Reset” button at remote 
control. 
 
Press “Auto OFF/ON button” to toggle remote control receiving sound. 
Short “beep”: Turn OFF remote control receiving sound. 
Long “beep”: Turn ON remote control receiving sound. 
 
After Auto OFF/ON Button is pressed, the 20 seconds counter for Remote Control Receiving Sound OFF/ON 
Mode is restarted. 
 
17.2  Heat Only Operation 
17.2.1 How 
to 
Activate/Deactivate Heat only Operation 
 
AUTO SW
is pressed
Emergency
Operation
Forced
Cooling
Operation
Forced
Cooling
Operation
Forced
Heating
Operation
Remote
Control
Number
Switch
Mode
Remote
Control
Receiving
Sound
OFF/ON
*Operation
Time Check
Mode
No
Setting
Mode
Heat Only
Mode
Enable/
Disable
AC reset code
AC reset code
AC reset code
AC reset code
AC reset code
CHECK
code
Beep
5s
8s
11s
16s
21s
26s
36s
BeepBeep
BeepBeepBeep BeepBeepBeepBeep
Beep
No
The unit will operate under forced cooling
mode continuously if “AC reset” code is
not pressed to activate standby
 
 
  To enable the “Heat Only” mode, press the AUTO OFF/ON SW for more than 8s and less than 11s, “Beep Beep” 
sound will be heard, then release the AUTO OFF/ON SW and press remote controller CHECK button. A short 
“Beep” sound will be heard. “Heat Only” mode is now enable. 
  To disable the “Heat Only” mode, press the AUTO OFF/ON SW for more than 8s and less than 11s, “Beep Beep” 
sound will be heard, then release the AUTO OFF/ON SW and press remote controller CHECK button. A long 
“Beep” sound will be heard. “Heat Only” mode is now disable. 
  To pump down the unit during Heat Only Operation press AUTO switch for 5 seconds. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
108 
17.2.2 Operation 
mode 
during Heating Only Operation 
  The table below shows the operation mode comparison when Heating Only Operation Mode Activated and 
Deactivated. 
 
Operation 
Mode 
Heating Only Operation Mode Activated 
Heating Only Operation Mode Deactivated 
AUTO 
After 30s sampling, regardless of the indoor intake or 
outdoor intake temperature judgment, the unit will run 
Heating operation. 
After 30s sampling, the unit will judge the operation 
mode base on remote controller temperature setting and 
Indoor Intake Sensor (New Auto Mode) or Outdoor 
Intake Sensor (Old Auto Mode). 
HEAT 
The unit will run Heating operation. 
The unit will run Heating operation. 
COOL 
The unit will stop and Power LED blinking. 
The unit will run Cooling operation. 
DRY 
The unit will stop and Power LED blinking. 
The unit will run Cooling Dry operation. 
NANOE 
Stand-alone 
The unit will stop and Power LED blinking. 
The unit will run Nanoe Stand-alone operation. 
Force Cooling 
The unit will run Force Cooling Operation for 
X_CTRYTM [15] minutes 
The unit will run Force Cooling operation. 
Force Heating 
The unit will run Force Heating operation. 
The unit will run Force Heating operation. 
AUTO 
(with Timer) 
The unit will turn ON by the timer and run Auto 
Operation. After 30s sampling, regardless of the indoor 
intake or outdoor intake temperature judgment, the unit 
will run Heating operation. 
The unit will turn ON by the timer and run Auto 
Operation. After 30s sampling, the unit will judge the 
operation mode base on remote controller temperature 
setting and Indoor Intake Sensor (New Auto Mode) or 
Outdoor Intake Sensor (Old Auto Mode). 
HEAT 
(with Timer) 
The unit will turn ON by the timer and run Heating 
Operation. 
The unit will turn ON by the timer and run Heating 
Operation. 
COOL 
(with Timer) 
The unit will not turn ON by the timer. Power LED 
blinking. 
The unit will turn ON by the timer and run Cooling 
Operation. 
DRY 
(with Timer) 
The unit will not turn ON by the timer. Power LED 
blinking. 
The unit will turn ON by the timer and run Cooling Dry 
Operation. 
Cooling 
Test Mode 
The unit will stop and Power LED blinking. 
The unit will operate according to specify Cooling test 
mode operation parameter. 
Heating  
Test Mode 
The unit will operate according to specify Heating test 
mode operation parameter. 
The unit will operate according to specify Heating test 
mode operation parameter. 
 
17.3 Remote Control Button 
17.3.1 SET 
Button 
  To check remote control transmission code and store the transmission code to EEPROM: 
o  Press “Set” button by using pointer. 
o  Press “Timer Set” button until a “beep” sound is heard as confirmation of transmission code changed. 
 
  To limit set temperature range for COOL & DRY, HEAT mode. 
o  Press “Set” button by using pointer. 
o  Press TEMP increment or decrement button to choose No. 3. 
o  Press Timer increment or decrement button to select desired temperature low limit of set temperature for 
COOL & DRY mode. 
o  Press Timer Set button to confirm low limit selection. 
o  Press TEMP increment or decrement button to choose No. 4. 
o  Press Timer decrement or increment button to select desired temperature high limit of set temperature for 
COOL & DRY mode. 
o  Press Timer Set button to confirm high limit selection. 
o  Press TEMP increment or decrement button to choose No. 5. 
o  Press Timer increment or decrement button to select desired temperature low limit of set temperature for 
HEAT mode. 
o  Press Timer Set button to confirm low limit selection. 
o  Press TEMP increment or decrement button to choose No. 6. 
o  Press Timer decrement or increment button to select desired temperature high limit of set temperature for 
HEAT mode. 
o  Press Timer Set button to confirm high limit selection. 
o  LCD returns to original display if remote control does not operate for 30 seconds or press Timer Cancel 
button. 
 
Page of 127
Display

Click on the first or last page to see other CS-Z20TKEW / CS-Z25TKEW / CS-Z35TKEW / CS-Z42TKEW / CS-Z50TKEW / CS-Z71TKEW / CS-XZ20TKEW / CS-XZ25TKEW / CS-XZ35TKEW / CS-XZ50TKEW / CU-Z20TKE / CU-Z25TKE / CU- / 35TKE / CU-Z42TKE / CU-Z50TKE / CU-Z71TKE / CU-Z20TKE / CU-Z25TKE / CU-Z35TKE / CU-Z50TKE service manuals if exist.