Time graph for Air Circulation Mode Operation
7.5. Air Circulation Mode Operation (For CS-SC7CKP only)
 1. An additional heater may make the warm air evenly covering each corner of the room.
 2. When the temperature near the ceiling reaches the setting temperature, Air Circulation Mode Operation commences at low
airflow volume. It stops when the temperature drops to 2°C below the setting temperature.
 3. The vertical airflow direction louver will not swing.
25
CS-SA7CKP / CU-SA7CKP5 / CS-SC7CKP / CU-SC7CKP5
7.6. Indoor Fan Motor Control
     • 
• 
• 
• Automatic fan speed control
When automatic fan speed set,the available range for fan speed is from H to SLo
     • 
• 
• 
• Manual Fan Speed Control
     • 
• 
• 
• Basic fan speed can be manually adjusted (Lo, Med,Hi) by using the fan speed selection button.
Basic Fan Speed
Rotating Speed Of Indoor Fan Motor
26
CS-SA7CKP / CU-SA7CKP5 / CS-SC7CKP / CU-SC7CKP5
Airflow Direction Auto-control
Airflow direction manual control
7.7. Airflow Direction Control
     • 
• 
• 
• When set at airflow direction auto-control with remote control, the louver swings up and down as shown in the table below.
     • 
• 
• 
• The louver does not swing when the indoor fan stops during operation.
     • 
• 
• 
• When stop the unit with remote control,the discharge vent is closed with the louver.
     • 
• 
• 
• When temperature of indoor heat exchanger reaches 38°C during heating mode operation, if temperature falls to 35°C, airflow
direction will change from the lower limit to horizontal.
The left and right airflow direction louver can be adjusted manually.
     • 
• 
• 
• When the airflow direction set button is pressed,the automatic airflow is released and the airflow direction louver moves up and
down as shown in the table below. The louver can be stopped by releasing the button at the desired position.
     • 
• 
• 
• When the remote control is used to stop the operation,the discharge vent is closed with airflow direction louver.
Notes:
In heating mode operation
 1. Airflow direction automatic control:
The airflow direction is automatically adjusted to horizontal direction when the temperature of indoor heat exchanger is low
and it will be automatically adjusted downward while the indoor temperature rises.
 2. Airflow direction manual control:
The airflow direction is automatically adjusted to horizontal direction temperature of indoor heat exchanger is low. While
temperature of indoor heat exchanger rises, the airflow direction is automatically adjusted to the place set by the remote
control.
In cooling or soft dry mode operation
If the compressor continues to operate for 60 minutes, and the louver direction is at No 4 or No 5,the fan speed is below Med,
the intake air temperature is below 29°C and continues to change between ±2°C for 30 minutes, the louver direction will be at
No 2 in order to prevent dew around the discharge vent.
27
CS-SA7CKP / CU-SA7CKP5 / CS-SC7CKP / CU-SC7CKP5
8.1. Before Installation
WARNING
INDOOR UNIT
OUTDOOR UNIT
Note: For CS-SC7CKP/CU-SC7CKP5,no drain
elbow.
8 Installation
! Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, electrical
shock or fire.
! Use the specified cable(1.5mm
2
) and connect tightly for indoor/outdoor connection.
! Power supply connection to a circuit breaker for the permanent connection. Use an approved 10A circuit breaker for the
permanent connection. It must be a double pole switch with a minimum 3 mm contact gap.
! The unit must be earthed, or it will cause fire or electric shock.
SELECT THE BEST LOCATION
     • 
• 
• 
• There should not be any heat source or steam near the unit.
     • 
• 
• 
• There should not be any obstacles blocking the air circulation.
     • 
• 
• 
• A place where air circulation in the room is good.
     • 
• 
• 
• A place where drainage can be easily done.
     • 
• 
• 
• A place where noise prevention is taken into consideration.
     • 
• 
• 
• Do not install the unit near the door way.
     • 
• 
• 
• Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles.
     • 
• 
• 
• Recommended installation height for indoor unit shall be at least 2.3m.
     • 
• 
• 
• If an awning is built over the unit to prevent direct sunlight or rain, be careful that heat radiation from the condenser is not
obstructed.
     • 
• 
• 
• There should not be any animal or plant which could be affected by hot air discharged.
     • 
• 
• 
• Keep the spaces indicated by arrows from wall, ceiling, fence or other obstacles.
     • 
• 
• 
• Do not place any obstacles which may cause a short circuit of the discharged air.
     • 
• 
• 
• If piping length is over the common length, additional refrigerant should be added.