Panasonic CS-SA7CKP / CU-SA7CKP5 / CS-SC7CKP / CU-SC7CKP5 Service Manual ▷ View online
2 Product Specifications
Unit
CS-SA7CKP
CU-SA7CKP5
Cooling Capacity
kW
2.05
Heating Capacity
kW
2.30
Moisture Removal
L/h
1.2
Power Source
Phase
V
Cycle
Single
220
50
Airflow Method
OUTLET
INTAKE
SIDE VIEW
TOP VIEW
Air Circulation
Indoor Air (low)
m
3
/min
Cooling: 6.04
—
Heating: 6.04
Indoor Air (medium)
m
3
/min
Cooling: 6.92
—
Heating: 6.92
Indoor Air (high)
m
3
/min
Cooling: 7.8
—
Heating: 7.8
Outdoor Air
m
3
/min
—
22.0
Noise Level
dB(A)
Cooling: High37, Low29
Cooling: High47
Heating: High37, Low29
Heating: High47
Electrical Data
Input
W
Cooling: 695
Heating: 620
Heating: 620
Running Current
A
Cooling: 3.45
Heating: 3.10
Heating: 3.10
EER/COP
W/W
Cooling: 2.95
Heating: 3.71
Heating: 3.71
Starting Current
A
16
Piping Connection Port (Flare piping)
Inch
Inch
Inch
G: half union 3/8"
L: half union 1/4"
G: 3-way valve 3/8"
L: 2-way valve 1/4"
Piping Size
(Flare piping)
(Flare piping)
Inch
Inch
Inch
G: gas side 3/8"
L: liquid side 1/4"
G: gas side 3/8"
L: liquid side 1/4"
Drain
Hose
Hose
Inner Diameter
mm
12
—
Length
m
0.6
—
Power Supply Cord Length (Number of core-wire)
m
2.2
3 core-wire/1.0mm
2
—
—
—
Dimensions
Height
mm
275
540
Width
mm
799
590
Depth
mm
210
255
Net Weight
kg
8.0
27.0
5
CS-SA7CKP / CU-SA7CKP5 / CS-SC7CKP / CU-SC7CKP5
* The amount of refrigerant (60g) for air purging not included
Unit
CS-SA7CKP
CU-SA7CKP5
Compressor
Type
—
Rotary(1 cylinder)
Rolling piston type
Motor
Type
—
Induction(2 pole)
Rated Output
W
—
600
Air Circulation
Type
Cross-flow fan
Propeller fan
Motor
Type
Induction (4 pole)
Induction (6 pole)
Input
W
37.4
58.3
Rated Output
W
13
15
Fan Speed
Low
rpm
960±60
—
Medium
rpm
1100±60
—
High
rpm
1240±60
880±60
Heat Exchanger
Description
Evaporator
Condenser
Tube Material
Copper
Copper
Fin Material
Slot Type
Corrugation type
Rows / Stage
(Plate fin configuration, forced draft)
2 × 10
1 × 20
FPI
18
16
Dimensions
mm
610 × 210 × 25.4
578.25 × 508.6 × 22
Refrigerant Control Device
—
Capillary Tube
Refrigeration Oil
(c.c)
—
SUNISO 4GDID or ATMOS M60
(M56)
Refrigerant (R-22)
g
—
620*
Thermostat
Electronic Control
—
Protection Device
—
OLP(30A/230V)
Capillary
Length
mm
—
Cooling: 645, Heating: 1160
Circulation
L/min
—
Cooling: 8.0, Heating: 4.5
Inner Diameter
mm
—
Cooling: 1.3, Heating: 1.2
Air Filter
P.P Honeycomb
—
Refrigerant Circulation Control Device
Capillary
Compressor Capacitor
µFV
—
20µF, 370V
Fan Motor Capacitor
µFV
1.5µF, 400V
1.2µF, 400V
•
•
•
• Specifications are subject to change without notice for further improvement
6
CS-SA7CKP / CU-SA7CKP5 / CS-SC7CKP / CU-SC7CKP5
Unit
CS-SC7CKP
CU-SC7CKP5
Cooling Capacity
kW
2.05
Moisture Removal
L/h
1.20
Power Source
Phase
V
Cycle
Single
220
50
Airflow Method
OUTLET
INTAKE
SIDE VIEW
TOP VIEW
Air Circulation
Indoor Air (low)
m
3
/min
5.43
—
Indoor Air (medium)
m
3
/min
6.13
—
Indoor Air (high)
m
3
/min
6.9
—
Outdoor Air
m
3
/min
—
—
Noise Level
dB(A)
Cooling: High35, Low28
Cooling: High46
Electrical Data
Input
W
680
Running Current
A
3.25
EER
W/W
3.01
Starting Current
A
15
Piping Connection Port
(Flare piping)
(Flare piping)
Inch
Inch
Inch
G: half union 3/8"
L: half union 1/4"
G: 3-way valve 3/8"
L: 2-way valve 1/4"
Piping Size
(Flare piping)
(Flare piping)
Inch
Inch
Inch
G: gas side 3/8"
L: liquid side 1/4"
G: gas side 3/8"
L: liquid side 1/4"
Drain
Hose
Hose
Inner Diameter
mm
12
—
Length
m
0.6
—
Power Supply Cord Length
(Number of core-wire)
(Number of core-wire)
m
2.2
3 core-wire/1.0mm
2
—
—
—
Dimensions
Height
mm
275
505
Width
mm
799
780
Depth
mm
210
245
Net Weight
kg
8.0
25
Compressor
Type
—
Rotary(1 cylinder)
Rolling piston type
Motor
Type
—
Induction(2 pole)
Rated Output
W
—
700
7
CS-SA7CKP / CU-SA7CKP5 / CS-SC7CKP / CU-SC7CKP5
* The amount of refrigerant (60g) for air purging not included.
Unit
CS-SC7CKP
CU-SC7CKP5
Air Circulation
Type
Cross-flow Fan
Propeller fan
Motor
Type
Induction (4 pole)
Induction (4 pole)
Input
W
31
60.7
Rate Output
W
13
15
Fan Speed
Low
rpm
920±60
—
Medium
rpm
1040±60
—
High
rpm
1170±60
875±30
Heat Exchanger
Description
Evaporator
Condenser
Tube Material
copper
copper
Fin Type
slot type
Corrugation type
Rows / Stage
(Plate fin configuration, forced draft)
2 × 10
1 × 20
FPI
18
16
Dimensions
mm
610 × 210 × 25.4
578.25 × 508 × 22
Refrigerant Control Device
—
Capillary Tube
Refrigeration Oil
(c.c)
—
SUNISO 4GDID or ATMOS M60
(M56)
Refrigerant (R-22)
g
—
530*
Thermostat
Electronic Control
—
Protection Device
—
OLP(30A/230V)
Capillary
Length
mm
—
865
Circulation
L/min
—
6.8
Inner Diameter
mm
—
1.3
Air Filter
P.P Honeycomb
—
Refrigerant Circulation Control Device
Capillary
Compressor Capacitor
µFV
—
30µF, 400V
Fan Motor Capacitor
µFV
1.5µF, 400V
1.2µF, 400V
•
•
•
• Specifications are subject to change without notice for further improvement.
8
CS-SA7CKP / CU-SA7CKP5 / CS-SC7CKP / CU-SC7CKP5
Click on the first or last page to see other CS-SA7CKP / CU-SA7CKP5 / CS-SC7CKP / CU-SC7CKP5 service manuals if exist.