SELECT THE BEST LOCATION
INDOOR UNIT
There should not be any heat source or steam near the
unit.
There should not be any obstacles blocking the air
circulation.
A place where air circulation in the room is good.
ıA place where drainage can be easily done.
ıA
place
where
noise
prevention
is
taken
into
consideration.
ıDo not install the unit near the door way.
ıEnsure the spaces indicated by arrows from the wall,
ceiling, fence or other obstacles.
ıRecommended installation height for indoor unit shall be
at least 2.5 m.
OUTDOOR UNIT
ıIf an awning is built over the unit to prevent direct
sunlight or rain, be careful that heat radiation from the
condenser is not obstructed.
There should not be any animal or plant which could be
affected by hot air discharged.
Keep the spaces indicated by arrows from wall, ceiling,
fence or other obstacles.
Do not place any obstacles which may cause a short
circuit of the discharged air.
If piping length is over the common length, additional
refrigerant should be added as shown in the table.
Indoor /Outdo or Unit Installa tion Diagra m
ıı ı
Attach ed access ories
33
CS-PC12DKD/ CU-PC12DKD / CS-PA12DKD / CU-PA12DKD
Attached accessories.
1
No.
Accessories part
Qty. No.
Accessories part
Qty.
1
2
3
4
Installation plate
Installation plate fixing
screw
Remote control
Battery
1
5
1
2
5
Drain elbow
1
6
Connecting Wire (Connector)
*
hr
DEL
A
Y
O
FF
O
N
A
UT
O
AU
T
O
FA
N
SP
EE
D
A
IR
SW
IN
G
MO
D
E
TE
M
P
O
FF
/O
N
TI
M
E
R
O
N
SE
T
A
IR
S
W
IN
G
O
FF
C
A
N
C
E
L
FA
N
S
P
EE
D
A
UTO
C
O
O
L
DRY
FA
N
O
FF
ST
D
Model
PC12DK
PA12DKD
Piping size
Max. Piping
Length
(m)
7
7
Max.
Elevation
(m)
5
5
Additional
Refrigerant
(g/m)
-
-
Gas
1/2"
1/2"
Liquid
1/4"
1/4"
Indoor/Outdoor Unit Installation Diagram
About 1.1 m
Piping direction
Attention not to
bend up drain hose
Length of power supply cord
Right
Right Bottom
Right Rear
Left
Rear
Left Bottom
Left
(Front side)
About 1.8 m
<
<
<
<
(Left and right are identical)
This illustration is for explanation purposes only.
The indoor unit will actually face a different way.
Installation plate
1
Sleeve ( )
Bushing Sleeve ( )
Putty (Gum type sealer) ( )
Vinyl tape (Wide) ( )
Apply after carrying out a
drainage test.
To carry out the drainage
test, remove the air filters
and pour water into the heat
exchanger.
Saddle ( )
Additional drain hose ( )
Bend the pipe as closely on
the wall as possible, but be
careful that it doesn't break.
Installation parts you
should purchase ( )
1/4" Liquid side piping (    )
10
cm
or
mor
e
Gas side piping ( ) 1/2"
100
cm
or mo
re
30
cm
or mo
re
5c
m
or
more
Insulation of piping connections
Carry out insulation
after checking for
gas leaks and
secure with vinyl
tape.
Vinyl tape
Type designation 245 IEC 57
or heavier cord
Connecting cable
(   )-
(3-CORE WIRE/1.5mm
2
)
5 cm
or more
10 ZZ
or more
(5-CORE WIRE/1.5mm
2
PC12DKD
(   )
PA12DKD
+2X0.5mm  )-
2
(Only for PA12DKD)
(Only for PA12DKD)
9.2.1.
SELECT THE BEST LOCATION
(Refer to “Select the best location

section)
9.2.2.
HOW TO FIX INSTALLATION
PLATE
The mounting wall is strong and solid enough to prevent it from
the vibration.
The centre of installation plate should be at more than 450 mm
at right and left of the wall.
The distance from installation plate edge to ceiling should more
than 67 mm.
From installation plate left edge to unit’s left side is 74 mm.
From installation plate right edge to unit’s right is 94 mm.
:
:
For left side piping, piping connection for gas should be
about 45 mm from this line.
For left side piping, piping connecting cable should be
about 800 mm from this line.
1. Mount the installation plate on the wall with 5 screws or
more.
(If mounting the unit on the concrete wall consider using
anchor bolts.)
Always mount the installation plate horizontally by
aligning the marking-off line with the thread and using a
level gauge.
2. Drill the piping plate hole with ø70 mm hole-core drill.
Line according to the arrows marked on the lower left
and right side of the installation plate. The meeting point
of the extended line is the centre of the hole. Another
method is by putting measuring tape at position as
shown in the diagram above. The hole centre is
obtained by measuring the distance namely 105 mm
and 145 mm for left and right hole respectively.
Drill the piping hole at either the right or the left and the
hole should be slightly slanted to the outdoor side.
9.2.3.
TO DRILL A HOLE IN THE WALL
AND INSTALL A SLEEVE OF
PIPING
1. Insert the piping sleeve to the hole.
2. Fix the bushing to the sleeve.
3. Cut the sleeve until it extrudes about 15 mm from the wall.
Caution
When the wall is hollow, please be sure to use the
sleeve for tube ass’y to prevent dangers caused by
mice biting the connecting cable.
4. Finish by sealing the sleeve with putty or caulking
compound at the final stage.
9.2.4.
INDOOR UNIT INSTALLATION
1. For the right rear piping
2. For the right and right bottom piping
9.2.
INDOOR UNIT
34
CS-PC12DKD/ CU-PC12DKD / CS-PA12DKD / CU-PA12DKD
B
Wall
Wall
More than 450 mm
More than 450 mm
Screw
2
150 mm
219 mm
125 mm
Measuring tape
A
Installation
plate
1
224mm
B
CS-PC12DKD/ CU-PC12DKD / CS-PA12DKD / CU-PA12DKD
35
9.2.5. CONNECT THE CABLE TO THE
INDOOR UNIT
 1. The inside and outside connecting cable can be connected
without removing the front grille.
 2. Connecting cable between indoor unit and outdoor unit
shall
be
approved
polychloroprene
sheathed
5
(PA12DKD) x 1.5 mm
2
flexible cord,
type designation 245 IEC 57 or heavier cord.
ıı ı
ı
ˇEnsure the color of wires of outdoor unit and the
terminal Nos. are the same to the indoor’s respectively.
ıı ı Earth lead wire shall be longer than the other lead wires
as shown in the figure for the electrical safety in case of
the slipping out of the cord from the anchorage.
36
CS-PC12DKD/ CU-PC12DKD / CS-PA12DKD / CU-PA12DKD
connector
1     2     3     4
(L)
(N)
CS-PA12DKD
 3  (PC12DKD)
x 1.5 mm  ,
2
CS-PA12DKD
ıı ı Secure the cable onto the control board with the holder
(clamper).
T
erminals on the indoor unit
1(L)
2(N)
Color of wires
Ter
minals on the outdoor unit
1(L)
2(N)
CS-PC12DKD
(L)
(N)
CS-PC12DKD
For PA12DKD, the attached wire    6   with two connectors 