Panasonic CS-PC12DKD / CU-PC12DKD / CSCU-PA12DKD / CU-PA12DKD Service Manual ▷ View online

AUTO
HEAT
COOL
DRY
OFF
AUTO
STD
FAN
SPEED
AIR
SWING
AUTO
8.9
About Cursor Key Which Points To “OFF” On Remote Control
AUTO
HEAT
COOL
DRY
OFF
AUTO
STD
PRESS "OFF/ON" BUTTON
FAN
SPEED
AIR
SWING
AUTO
1.
2.
When the ON/OFF button on the remote control is pressed, the cursor key which points to “OFF” will appear or
disappear to indicate the ON/OFF status of the air conditioner.
The air conditioner is running but the cursor key which points to “OFF” appears. The air conditioner can be
stopped with any button (Except for “ON/OFF”, “TIMER SET”, “TIMER ON”) pressed.
The air conditioner is on standby, but the cursor key which points to “OFF” disappears. The air conditioner can
be started with any button(Except for “ON/OFF”, “TIMER SET”, “TIMER OFF”) pressed.
For some reason (Ex. The signal of the remote control does not reach the signal receiver of the indoor unit.), the
display of the remote control will not correspond with the actual ON/OFF status of the indoor unit:
29
8.10.
Indoor Fan Motor Control
Automatic fan speed control
When automatic fan speed set, the available range for fan speed is from Hi to Slo.
Basic Fan Speed
Cooling Mode
Operation
Soft Dry
Operation
Manual
Auto
Category
Hi
Me
Lo
Lo-
Manual
Auto
Manual Fan Speed Control
Basic fan speed can be manually adjusted (Lo, Med, Hi) by using the fan speed selection button.
Manual
Auto
SLo
SSLo
Heating Mode
Operation
8.11.
Auto restart control
If the operation is stopped due to a power failure u
, it will restart automatically
un der the previous operation mode when the power supply is resumed.
nder any operation mode
CS-PC12DKD / CU-PC12DKD / CS-PA12DKD / CU-PA12DKD
30
8.12.
Airflow Direction Control
Cooling
Soft dry
Operating Mode
Determining operation
mode
Manual
Auto
Manua
Auto
1
2
3
4
5
12
17
26
32
36
o
o
o
o
o
12 ~36
o
o
9
o
9
21
29
44
55
o
o
o
o
o
Heating
9 ~55
o
o
Airflow Direction Auto-control
The left and right airflow direction louver can be adjusted manually.
Airflow direction manual control
When the airflow direction set button is pressed,the automatic airflow is released and the
airflow direction louver moves up and down as shown in thetable below. The louver can
be stopped by releasing the button at the desired position.
When the remote control is used to stop the operation,the discharge vent is closed with
airflow direction louver.
When set at airflow direction auto-control with remote control,the louver swings up and down as shown in the table below.
The louver does not swing when the indoor fan stops during operation.
When stop the unit with remote control,the discharge vent is closed with the louver.
When temperature of indoor heat exchanger reaches 38
during heating mode operation, if temperature falls to 35 ,airflow
direction will change from the lower limit to horizontal.
Angles Of Airflow Direction Louver
Notes:
In heating mode operation
1.
Airflow direction is automatically adjusted to horizontal direction when the temperature of indoor heat exchanger is low and it will
be automatically adjusted downward while the indoor temperature rises.
2.
The airflow direction is automatically adjusted to horizontal direction when temperature of indoor heat exchanger is low .While
temperature of indoor heat temperature rises ,the airflow direction is automatically adjusted to the place set by the remote control.
Airflow direction automatic control:
Airflow direction manual control:
In cooling or soft dry mode operation
If the compressor continues to operate for 60 minutes ,and the louver direction is at No 5,the fan speed is below Med, the intake
air temperature is below 29
and continues to change between 2
for 30 minutes ,the louver direction will be at No 2 in order
to prevent dew around the discharge vent.
CS-PC12DKD / CU-PC12DKD / CS-PA12DKD / CU-PA12DKD
9 Installation Instructions
Required tools for Installation Works
1.
Philips screw driver
5.
Spanner
9.
Gas leak detector
13. Multimeter
2.
Level gauge
6.
Pipe cutter
10. Measuring tape
14. Torque wrench
18 N.m (1.8 kgf.m)
42 N.m (4.2 kgf.m)
55 N.m (5.5 kgf.m)
3.
Electric drill, hole core drill
(ø70 mm)
7.
Reamer
11. Thermometer
15. Vacuum pump
4.
Hexagonal wrench (4 mm)
8.
Knife
12. Megameter
16. Gauge manifold
9.1.
Safety Precautions
Read the following "SAFETY PRECAUTIONS" carefully before installation.
Electrical work must be installed by a licensed electrician.
The caution items stated here must be followed because these important contents are related to safety. The meaning of each
indication used is as below. Incorrect installation due to ignoring of the instruction will cause harm or damage, and the
seriousness is classified by the following indications.
This indication shows the possibility of causing death or serious injury.
This indication shows the possibility of causing injury or damage to properties only.
The items to be followed are classified by the symbols:
Symbol with background white denotes item that is PROHIBITED from doing.
Carry out test running to confirm that no abnormality occurs after the installation. Then, explain to user the operation, care and
maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference.
1.
Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, electrical shock or fire.
2.
Install according to this installation instruction strictly. If installation is defective, it will cause water leakage, electrical shock or fire.
3.
Use the attached accessories parts and specified parts for installation. Otherwise, it will cause the set to fall, water leakage, fire or
electrical shock.
4.
Install at a strong and firm location which is able to withstand the set• sweight. If the strength is not enough or installation is not properly
done, the set will drop and cause injury.
5.
For electrical work, follow the local national wiring standard, regulation and this installation instruction. An independent circuit and single
outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire.
6.
Use the specified cable (1.5 mm
2
) and connect tightly for indoor/outdoor connection. Connect tightly and clamp the cable so that no
external force will be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection.
7.
Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will
cause heat-up at connection point of terminal, fire or electrical shock.
8.
When carrying out piping connection, take care not to let air substances other than the specified refrigerant go into refrigeration cycle.
Otherwise, it will cause lower capacity, abnormal high pressure in the refrigeration cycle, explosion and injury.
9.
When connecting the piping, do not allow air or any substances other than the specified refrigerant ( R22 ) to enter the
refrigeration cycle. Otherwise, this may lower the capacity, cause abnormally high pressure in the refrigeration cycle, and
possibly result in explosion and injury.
10.Do not modify the length of the power supply cord or use of the extension cord, and do not share the single outlet with
other electrical appliances. Otherwise, it will cause fire or electrical shock. if the power supply cord is damaged, engage an
31
CS-PC12DKD/ CU-PC12DKD / CS-PA12DKD / CU-PA12DKD
authorized dealer to replace it.
1.
The equipment must be earthed. It may cause electrical shock if grounding is not perfect.
2.
Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at
surrounding of the unit, it may cause fire.
3.
Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the
furniture.
1. Selection of the installation location.
Select a installation location which is rigid and strong enough to support or hold the unit, and select a location for easy maintenance.
2.
Power supply connection to the room air conditioner.
Connect the power supply cord of the room air conditioner to the mains using one of the following method.
Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency.
In some countries, permanent connection of this room air conditioner to the power supply is prohibited.
1. Power supply connection to the receptacle using a power plug.
Use an approved 10A power plug with earth pin for the connection to the socket.
2. Power supply connection to a circuit breaker for the permanent connection. Use an approved 10A circuit breaker for the permanent
connection. It must be a double pole switch with a minimum 3 mm contact gap.
3.
Do not release refrigerant.
Do not release refrigerant during piping work for installation, reinstallation and during repairing a refrigeration parts. Take care of the
liquid refrigerant, it may cause frostbite.
4.
Installation work.
It may need two people to carry out the installation work.
5.
Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.
32
CS-PC12DKD/ CU-PC12DKD / CS-PA12DKD / CU-PA12DKD
Page of 63