DOWNLOAD Panasonic CS-MC95KE / CS-MC125KE / CS-MC76KE / CS-MC126KE / CU-MC145KE / CU-MC185KE / CU-MC205KE / CU-MC245KE / CU-MC196KE Service Manual ↓ Size: 13.02 MB | Pages: 126 in PDF or view online for FREE

Model
CS-MC95KE CS-MC125KE CS-MC76KE CS-MC126KE CU-MC145KE CU-MC185KE CU-MC205KE CU-MC245KE CU-MC196KE
Pages
126
Size
13.02 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / SPLIT TYPE
File
cs-mc95ke-cs-mc125ke-cs-mc76ke-cs-mc126ke-cu-mc145.pdf
Date

Panasonic CS-MC95KE / CS-MC125KE / CS-MC76KE / CS-MC126KE / CU-MC145KE / CU-MC185KE / CU-MC205KE / CU-MC245KE / CU-MC196KE Service Manual ▷ View online

Recommended Setting of Timer
When you sleep
Set the time at which you will go to sleep with the
OFF-TIMER. This prevent wastage of electricity.
When you wake up
Set the time at which you will wake up with the
ON-TIMER. You can start the new day at a comfortable
temperature.
Note:
(The above is an example of how you can used the
OFF-TIMER and ON-TIMER mode. However it is
recommended to use the sleep mode function for sleeping)
When going out
Set  the time at which you will go out with the
OFF-TIMER. Set the time at which you will come back
with the ON-TIMER.
This will prevent the air conditioner from being left on
while you are out, and the temperature will be pleasant
when you return.
When you return
Set the time at which you will return with the ON-TIMER.
This will make the temperature pleasant when you
return, and it will prevent the air conditioner from being
left on.
Timer details
The current time is not displayed when the timers are set.
When both timers are used together, the TIMER LED on the indoor unit remains lit even if the operation is stopped by the
OFF-TIMER.
Good Night!
RING...
RING...
Good Morning!
Not at Home
Bye
Hi! I’m home
53
CS-MC95KE CU-MC145KE / CS-MC95KE CU-MC185KE / CS-MC95KE CU-3MC205KE / CS-MC125KE CU-MC245KE / CS-MC76KE / CS-MC126KE CU-MC196KE
CONVENIENCE OPERATION
To set the sleep mode, press SLEEP.
*
The sleep indicator on the indoor unit will
light up.
To cancel the sleep mode, press once
more.
AIR SWING
TIMER
CLO
CK
1
2
3
COOL
MODE
ECONOMY
FAN SPEED
AUTO
MANUAL
ON
OFF
SET
CANCEL
SLEEP
When the room temperature reaches the setting
temperature, the airflow volume will automatically change
to low.
Sleep Mode Operation time is 8 hours.
When used together with the timer, the timer has priority.
Cooling or Soft Dry Operation for sleep mode movement
will start to avoid overcooling.
Operation details
This is to obtain a comfortable room temperature while sleeping.
Sleep Mode
Time
Approx. 0.5°C increase.
Setting temperature
Temperature
Sleep Operation button is
pressed.
Sleep shift operation starts.
0-1 hour
1 hour
Approx. 0.5°C increase.
Approx. 8 hours after sleep
shift operation starts, stops
automatically.
54
CS-MC95KE CU-MC145KE / CS-MC95KE CU-MC185KE / CS-MC95KE CU-3MC205KE / CS-MC125KE CU-MC245KE / CS-MC76KE / CS-MC126KE CU-MC196KE
AIR SW
ING
TIM
ER
CLO
CK
1
2
3
COOL
MODE
ECONOMY
FAN SPEED
AUTO
MANUAL
ON
OFF
SET
CANCEL
SLEEP
PO
W
ERFUL
OFF/ON
Economy or Powerful Mode
Operation details
Cover
is closed
Economy operation
Powerful operation
Cooling/Soft Dry
Airflow volume
Super High
Airflow volume
Low (on and off)
Economy Mode
To save electrical power consumption.
However, please use this mode when the room have
reached your desired temperature.
Press ECONOMY
*
Economy indicator (Green) on indoor unit lights
up.
Press once more to cancel this operation.
Powerful Mode
To obtain the setting temperature quickly.
Press POWERFUL
*
Powerful indicator (Orange) on indoor unit lights
up.
*
Powerful mode will operate for 15 minutes only.
To cancel this operation, press once more.
Temperature
3°C lower than set
temp.
Temperature
0.5°C higher than set
temp.
Economy and Powerful operation cannot be selected simultaneously.
*
The changes of the temperature and airflow volume are automatic.
The remote control display remain unchanged.
If sleep button or operation mode button is pressed, economy or powerful operation is cancelled.
During         -Air circulation operation, the powerful and economy operation are not available.
During Economy mode, indoor fan operates on and off at Low speed.
FAN
55
CS-MC95KE CU-MC145KE / CS-MC95KE CU-MC185KE / CS-MC95KE CU-3MC205KE / CS-MC125KE CU-MC245KE / CS-MC76KE / CS-MC126KE CU-MC196KE
5
Let it dry and reinstall it.
Be sure the “FRONT” mark is facing you.
*
Damaged air filter.
Consult the nearest authorized dealer.
Part No.: CWD00240.
Do not clean using benzene, thinner, scouring powder or cloths
soaked in caustic chemicals.
2
Remove dirt using a
vacuum cleaner.
3
Wash back of the air filter
with water.
CARE AND MAINTENANCE
Cleaning the Air Filter
Switch OFF and unplug the power cord before cleaning
the air conditioner.
!
  
    
    
Caution
4
If badly soiled, wash it
with soap or a mild
household detergent.
Cleaning the Indoor Unit and Remote Control
Wipe gently with a soft, dry cloth.
Do not clean with water hotter than 40°C or with
polishing fluids.
The front panel can be removed and cleaned
with water.
1
Open the front grille and remove the two
air filters. Hold the tab, lift up slightly
then pull down.
Thinner
Benzene
POWER
ECONOMY
POWERFUL
SLEEP
TIMER
(Recommendation:- If the unit is operated in a dusty environment, clean the filters every two weeks, continuous use of
this dirty filters will reduce cooling efficiency)
56
CS-MC95KE CU-MC145KE / CS-MC95KE CU-MC185KE / CS-MC95KE CU-3MC205KE / CS-MC125KE CU-MC245KE / CS-MC76KE / CS-MC126KE CU-MC196KE
Page of 126
Display

Click on the first or last page to see other CS-MC95KE / CS-MC125KE / CS-MC76KE / CS-MC126KE / CU-MC145KE / CU-MC185KE / CU-MC205KE / CU-MC245KE / CU-MC196KE service manuals if exist.