DOWNLOAD Panasonic CS-MC95KE / CS-MC125KE / CS-MC76KE / CS-MC126KE / CU-MC145KE / CU-MC185KE / CU-MC205KE / CU-MC245KE / CU-MC196KE Service Manual ↓ Size: 13.02 MB | Pages: 126 in PDF or view online for FREE

Model
CS-MC95KE CS-MC125KE CS-MC76KE CS-MC126KE CU-MC145KE CU-MC185KE CU-MC205KE CU-MC245KE CU-MC196KE
Pages
126
Size
13.02 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / SPLIT TYPE
File
cs-mc95ke-cs-mc125ke-cs-mc76ke-cs-mc126ke-cu-mc145.pdf
Date

Panasonic CS-MC95KE / CS-MC125KE / CS-MC76KE / CS-MC126KE / CU-MC145KE / CU-MC185KE / CU-MC205KE / CU-MC245KE / CU-MC196KE Service Manual ▷ View online

 1 
Features 
2
 2 
Functions 
3
 3 
Product Specifications 
6
 4 
Dimensions 
16
 5 
Refrigeration Cycle Diagram 
20
 6 
Block Diagram 
23
 7 
Wiring Diagram 
28
 8 
Operation Details 
33
CS-MC95KE CU-MC145KE
CS-MC95KE CU-MC185KE
CS-MC95KE CU-3MC205KE
CS-MC125KE CU-MC245KE
CS-MC76KE
CS-MC126KE CU-MC196KE
 9 
Operating Instructions 
41
 10 Installation Instructions 
65
 11 3-way Valve 
76
 12 2-way, 3-way Valve 
83
 13 Servicing Information 
90
 14 Troubleshooting Guide 
94
 15 Technical Data 
96
 16 Exploded View 
104
Multi-Split Air Conditioner
CONTENTS
 Page 
Page
Order No: MAC0011057C2
 17 Replacement Parts List 
105
 18 Exploded View 
106
 19 Replacement Parts List 
107
 20 Exploded View 
108
 21 Replacement Parts List 
109
 22 Exploded View 
110
 23 Replacement Parts List 
111
 24 Exploded View 
112
  • 
High Efficiency
  • 
Compact Design
  • 
Comfort Environment
  − 
8 hours of sleep mode operation
  − 
Air filter with function to reduce dust and smoke
  − 
Wider range of horizontal discharge air
  • 
Auto Restart
  − 
Random auto restart after power failure for safety restart
operation
  • 
Removable and Washable Front Panel
  • 
Remote Control Self-illuminating Button
  • 
Catechin Air Purifying Filter
  − 
Trap dust, tabacco smoke and tiny particles
  − 
Prevent the growth of bacteria and viruses trapped
  • 
Deodorizing Air Purifying Filter
  − 
Remove unpleasant odors from the air
 25 Replacement Parts List 
113
 26 Exploded View 
114
 27 Replacement Parts List 
115
 28 Exploded View 
116
 29 Replacement Parts List 
117
 30 Electronic Parts List 
118
 31 Electronic Circuit Diagram 
119
  • 
Quality Improvement
  − 
Gas leakage protection
  − 
Prevent compressor reverse cycle
  − 
2-stage OLP to protect compressor
  − 
Noise prevention during soft dry operation.
  • 
Service Improvement
  − 
Easy fan motor replacement procedure
  • 
Operation Improvement
  − 
Economy mode to reduce electrical power consumption
  − 
Powerful mode to reach the desired room temperature
quickly
  • 
Long Installation Piping
  − 
Long piping up to 15 meter
1 Features
2
CS-MC95KE CU-MC145KE / CS-MC95KE CU-MC185KE / CS-MC95KE CU-3MC205KE / CS-MC125KE CU-MC245KE / CS-MC76KE / CS-MC126KE CU-MC196KE
2 Functions
Remote Control
Operation OFF / ON
OFF / ON 
I
Room Temperature Setting
TEMP.
Operation Mode Selection
AUTO
Automatic Operation Mode
COOL
Cooling Operation Mode
DRY
Soft Dry Operation Mode
FAN
Air Circulation Mode
MODE
TIMER
Time / Timer Setting
• Hours and minutes setting.
Clock Setting
• Current time setting.
Sleep Mode Operation OFF / ON
SLEEP
Indoor Fan Speed Selection
FAN SPEED
h j k
Low Speed
l
h j k
Medium Speed
lll
h j k
High Speed
lllll
AUTOFAN
Automatic Fan Speed
Airflow Direction Control
• 24-hour, OFF / ON Real Timer Setting.
ON-TIMER
OFF-TIMER
Timer Operation Selection
SET
CANCEL
Timer Operation Set / Cancel
• ON Timer and OFF Timer setting and
cancellation.
CLOCK
AIR SWING
AUTO
Automatic Airflow Direction
Control
MANUAL
Airflow Direction Manual
Control
Powerful Mode Operation OFF/ON
POWERFUL
Economy Mode Operation OFF/ON
ECONOMY
• Temperature Setting (16°C to 30°C)
• Automatic Operation
2°C higher than standard
Standard
2°C lower than standard
HI
a
a
a
Lo
Self illuminating
button
3
CS-MC95KE CU-MC145KE / CS-MC95KE CU-MC185KE / CS-MC95KE CU-3MC205KE / CS-MC125KE CU-MC245KE / CS-MC76KE / CS-MC126KE CU-MC196KE
Indoor Unit
Random Auto Restart Control
• Operation is restarted randomly after
power failure at previous setting mode.
Anti-Freezing Control
• Anti-Freezing control for indoor heat
exchanger. (Cooling and Soft Dry)
Sleep Mode Auto Control
• Indoor Fan operates at Low speed.
• Operation stops after 8 hours.
Indoor Fan Speed Control
• High, Medium and Low.
• Automatic Fan Speed Mode
Cooling : Fan rotates at Hi and Me
speed. Deodorizing control
is available.
Soft Dry: Fan rotates at Lo speed.
Deodorizing control
is available.
• Automatic air swing and manual adjusted
by remote control for vertical airflow.
• Manually adjusted by hand for horizontal airflow.
Airflow Direction Control
Automatic Operation Button
• Press for < 5s to operate Automatic
operation mode.
(Used when the remote control cannot be used.)
• Press continuously for 5s or < 10s  to
operate Test Run/Pump down. “Beep”
sound will be heard at the 5th second.
(Used when test running or servicing.)
• Press continuously for 10s and above to
omit or resume the remote control signal
receiving sound. “Beep, beep” sound will
be heard at the 10th second.
AUTO
OFF / ON
Operation Indication Lamps (LED)
POWER
 (Green) ........ Lights up in operation,
blinks in Automatic
Operation Mode
judging.
SLEEP
 (Orange) ........ Lights up in Sleep
Mode Operation.
TIMER
 (Orange) ....... Lights up in Timer
Setting.
POWERFUL
 (Orange) .. Lights up in Powerful
Mode Operation.
ECONOMY
 (Green) ..... Lights up in Economy
Mode Operation.
Operation Mode
• Cooling, Soft Dry, Air Circulation and
Automatic Mode.
Powerful Operation
• Reaches the desired room temperature
quickly.
Time Delay Safety Control
• Restarting is inhibited for appro. 3
minutes.
Starting Current Control
Economy Operation
• To reduce electrical power consumption.
7 Minutes Time Save Control
• Cooling Operation only.
4
CS-MC95KE CU-MC145KE / CS-MC95KE CU-MC185KE / CS-MC95KE CU-3MC205KE / CS-MC125KE CU-MC245KE / CS-MC76KE / CS-MC126KE CU-MC196KE
Page of 126
Display

Panasonic CS-MC95KE / CS-MC125KE / CS-MC76KE / CS-MC126KE / CU-MC145KE / CU-MC185KE / CU-MC205KE / CU-MC245KE / CU-MC196KE Service Manual ▷ Download

  • DOWNLOAD Panasonic CS-MC95KE / CS-MC125KE / CS-MC76KE / CS-MC126KE / CU-MC145KE / CU-MC185KE / CU-MC205KE / CU-MC245KE / CU-MC196KE Service Manual ↓ Size: 13.02 MB | Pages: 126 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Panasonic CS-MC95KE / CS-MC125KE / CS-MC76KE / CS-MC126KE / CU-MC145KE / CU-MC185KE / CU-MC205KE / CU-MC245KE / CU-MC196KE in PDF for free, which will help you to disassemble, recover, fix and repair Panasonic CS-MC95KE / CS-MC125KE / CS-MC76KE / CS-MC126KE / CU-MC145KE / CU-MC185KE / CU-MC205KE / CU-MC245KE / CU-MC196KE Air Conditioner. Information contained in Panasonic CS-MC95KE / CS-MC125KE / CS-MC76KE / CS-MC126KE / CU-MC145KE / CU-MC185KE / CU-MC205KE / CU-MC245KE / CU-MC196KE Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.