Panasonic CS-LE9NKD / CS-LE12NKD / CU-LE9NKD / CU-LE12NKD Service Manual ▷ View online
5
2. Specification
Indoor
CS-LE9NKD
CS-LE12NKD
Model
Outdoor
CU-LE9NKD
CU-LE12NKD
Phase, Hz
Single, 50
Single, 50
Power Supply
V
220
220
Min
Rate
Max
Min
Rate
Max
kW
0.90
2.50
3.00
0.900
3.300
3.900
BTU/h
3070
8530
10230
3070
11250
13300
Capacity
kcal/h
770
2150
2580
770
2840
3350
Running Current
A
-
3.70
-
-
5.00
-
Input Power
W
190
760
1000
200
1020
1300
W/W
4.73
3.28
3.00
4.50
3.23
3.00
EER
BTU/hW
16.15
11.22
10.23
15.35
11.02
10.23
Power Factor
%
93
92
dB-A (H / L /
QLo)
QLo)
Hi: 40 Lo: 27 QLo: 22
Hi: 42 Lo: 30 QLo: 22
Indoor Noise
Power Level
56
58
dB-A (H / L )
Hi: 47 Lo: -
Hi: 48 Lo: -
C
O
O
L
IN
G
Outdoor Noise
Power Level
63
64
kW
0.90
3.20
4.20
0.90
4.00
5.00
BTU/h
3070
10900
14320
3070
13640
17050
Capacity
kcal/h
770
2750
3610
770
3440
4300
Running Current
A
-
4.30
-
-
5.20
-
Input Power
W
190
880
1200
200
1060
1420
W/W
4.73
3.63
3.50
4.50
3.77
3.52
COP
BTU/hW
16.15
12.38
11.93
15.35
12.86
12.00
Power Factor
%
93
92
dB-A (H / L /
QLo)
QLo)
Hi: 40 Lo: 27 QLo: 23
Hi: 42 Lo: 33 QLo: 25
Indoor Noise
Power Level
56
58
dB-A (H / L )
Hi: 48 Lo: -
Hi: 50 Lo: -
H
E
A
T
IN
G
Outdoor Noise
Power Level
64
66
Max Current (A) / Max Input Power (W)
6.50 / 1.350k
8.80 / 1.600k
Starting Current (A)
4.00
5.40
Type
Hermetic Motor
Hermetic Motor
Motor Type
BRUSHLESS (6 poles)
BRUSHLESS (6 poles)
Compressor
Output Power
W
750
900
Type
Cross-flow fan
Cross-flow fan
Material
AS(GF30%)
AS(GF30%)
Motor Type
AC (4 poles)
AC (4 poles)
Input Power
W
58.19
61.16
Output Power
W
30
30
Q-Lo
rpm
580
560
Lo
rpm
750
760
Me
rpm
910
960
Speed
(COOLING)
(COOLING)
Hi
rpm
1060
1150
Q-Lo
rpm
600
700
Lo
rpm
700
850
Me
rpm
820
970
In
d
o
o
r
F
a
n
Speed
(HEATING)
(HEATING)
Hi
rpm
1020
1100
Type
Propeller
Propeller
Material
PP(GF+PD)30%
PP(GF+PD)30%
Motor Type
AC (6 poles)
AC (6 poles)
Input Power
W
60.72
72.60
Output Power
W
25
30
Hi(C)
rpm
710
800
O
u
td
o
o
r
F
a
n
Speed
Hi(H)
rpm
690
760
Moisture Removal
L/h (Pt/h)
1.4 (2.4)
1.9 (3.3)
Q-Lo
m
3
/min (ft
3
/m)
6.6(232)
6.5 (229)
Lo
m
3
/min (ft
3
/m)
8.5(300)
8.8 (319)
Indoor Airflow
(COOLING)
(COOLING)
Me
m
3
/min (ft
3
/m)
10.3(364)
11.1 (392)
6
Hi
m
3
/min (ft
3
/m)
12.0 (424)
13.3 (470)
Q-Lo
m
3
/min (ft
3
/m)
6.8 (239)
8.0 (283)
Lo
m
3
/min (ft
3
/m)
7.9 (279)
9.7 (344)
Me
m
3
/min (ft
3
/m)
9.2 (326)
11.1 (392)
Indoor Airflow
(HEATING)
(HEATING)
Hi
m
3
/min (ft
3
/m)
11.5 (406)
12.6 (445)
Hi (Cooling)
m
3
/min (ft
3
/m)
32.9 (1162)
36.8 (1300)
Outdoor Airflow
Hi (Heating)
m
3
/min (ft
3
/m)
32.9 (1162)
36.8 (1300)
Control Device
Capillary Tube
Capillary Tube
Refrigerant Oil
cm
3
FV50S (250)
FV50S (320)
Refrigeration
Cycle
Cycle
Refrigerant Type g (oz)
R410A, 640 (22.6)
R410A, 690 (24.4)
Height(I/D / O/D) mm (inch)
283 (11-15/32) 530 (20-55/64) 283 (11-5/32) 624 (24-37/64)
Width (I/D / O/D) mm (inch)
803 (31-5/8)
720 (28-11/32)
803 (31-5/8)
780 (30-45/64)
Dimension
Depth (I/D / O/D) mm (inch)
216 (8-1/2)
275 (10-53/64)
216 (8-1/2)
289 (11-3/8)
Weight
Net (I/D / O/D)
kg (lb)
8.5 (19)
20 (44)
8.5 (19)
24 (53)
Pipe Diameter
(Liquid / Gas)
(Liquid / Gas)
mm (inch)
6.35 (1/4) / 9.52 (3/8)
6.35 (1/4) / 9.52 (3/8)
Standard length
m (ft)
5 (16.4)
5 (16.4)
Length range (min – max) m (ft)
3 (9.8) ~ 15 (49.2)
3 (9.8) ~ 15 (49.2)
I/D & O/D Height different m (ft)
5.0 (16.4)
5.0 (16.4)
Additional Gas Amount
g/m (oz/ft)
20 (0.2)
20 (0.2)
P
ip
in
g
Length for Additional Gas m (ft)
7.0 (23.0)
7.0 (23.0)
Inner diameter
mm
16
16
Drain Hose
Length
mm
500
500
Fin Material
Pre coated
Pre coated
Fin Type
Slit Fin
Slit Fin
Row x Stage x FPI
2 x 16 x 19
2 x 16 x 19
Indoor
Heat
Exchanger
Heat
Exchanger
Size (W x H x L)
mm
610 x 336 x 25.4
610 x 336 x 25.4
Fin Material
Pre coated
Pre coated
Fin Type
Slit Fin
Slit Fin
Row x Stage x FPI
1 x 24 x 19
1 x 28 x 18
Outdoor
Heat
Exchanger
Heat
Exchanger
Size (W x H x D)
mm
661 x 504 x 18.19
715 x 588 x 18.19
Material
PP-12X13H2
PP-12X13H2
Air Filter
Type
One-touch
One-touch
Power Supply
Indoor
Indoor
Power Supply Cord
A
10A
10A
Thermostat
-
-
Protection Device
-
-
COOLING
HEATING
COOLING
HEATING
TEMPERATURE (°C )
DB
WB
DB
WB
DB
WB
DB
WB
Maximum
32
23
30
-
32
23
30
-
Indoor Operation Range
Minimum
16
11
16
-
16
11
16
-
Maximum
43
26
24
18
43
26
24
18
Outdoor Operation Range
Minimum
16
11
-5
-6
16
11
-5
-6
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19°C Wet Bu lb (66.2°F
Wet Bulb) and outdoor air temperature of 35°C Dry B ulb (95.0°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bu lb).
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor ai r
temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb).
3. Specifications are subjected to change without prior notice for further improvement.
7
3. Features
•
Inverter Technology
o
Wider output power range
o
Energy saving
o
Quick Cooling
o
More precise temperature control
•
Long Installation Piping
o
CS/CU-LE9/12NKD, long piping up to 15 meters.
•
Easy to use remote control
•
Quality Improvement
o
Random auto restart after power failure for safety restart operation
o
Gas leakage protection
o
Prevent compressor reverse cycle
o
Inner protector to protect compressor
•
Operation Improvement
o
Quiet mode to reduce the indoor unit operating sound
o
Powerful mode to reach the desired room temperature quickly
o
AUTO COMFORT & ECONAVI operation
o
12-hour timer
•
Serviceability Improvement
o
Breakdown Self Diagnosis Function.
8
4. Location of Controls and Components
4.1 Indoor Unit
4.2 Outdoor Unit
4.3 Remote Control
For normal operation, ERROR RESET and CHECK button is not in use.
Press RESET button to restore the remote control’s default setting.
POWER
GREEN
TIMER
ORANGE
AUTO COMFORT
GREEN
INDICATOR
ECONAVI
GREEN
Front Panel
Horizontal airflow
Direction louver
Direction louver
Air Filter
Vertical airflow
Direction louver
Direction louver
Receiver
Human
activity
sensor
activity
sensor
Transmitter
OFF/ON
Fan speed selection
(
Quiet Mode included
)
Powerful mode
Operation mode
Temperature setting
Vertical Airflow direction adjustment
ECONAVI(For energy saving)
AUTO COMFORT
(To maximize comfort)
(To maximize comfort)
Timer setting
Click on the first or last page to see other CS-LE9NKD / CS-LE12NKD / CU-LE9NKD / CU-LE12NKD service manuals if exist.