8. Block Diagram 
CS/CU-LE9NKD 
 
 
 
 
 
 
14 
CS/CU-LE12NKD 
 
 
 
15 
9. Printed Circuit Board 
9.1  Indoor Unit 
 
 
 
 
 
16 
10.  Installation Instruction 
10.1  Select the Best Location 
10.1.1  Indoor Unit 
 
Do not install the unit in excessive oil fume area such as kitchen,  
workshop and etc.  
 
There should not be any heat source or steam near the unit.  
 
There should not be any obstacles blocking the air circulation. 
 
A place where air circulation in the room is good. 
 
A place where drainage can be easily done. 
 
A place where noise prevention is taken into consideration. 
 
Do not install the unit near the door way.  
 
Ensure the spaces indicated by arrows from the wall, ceiling, fence or 
other obstacles. 
 
Recommended installation height for indoor unit shall be at least 2.5m. 
10.1.2  Outdoor Unit 
 
If an awning is built over the unit to prevent direct sunlight or rain, be 
careful that heat radiation from the condenser is not obstructed. 
 
There should not be any animal or plant which could be affected by 
hot air discharged. 
 
Keep the spaces indicated by arrows from wall, ceiling, fence or other 
obstacles. 
 
Do not place any obstacles which may cause a short circuit of the 
discharged air. 
 
If piping length is over the[piping length for add. Gas], additional 
refrigerant should be added as shown in the table below: 
 
 
Example: If the unit is installed at a 10m distance, the quantity of 
additional refrigerant should be 60g.…… (10-7)m x 20g/m = 60g 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Piping size 
Model 
Gas  Liquid 
Rated 
Length 
(m) 
Max 
Elevation 
(m) 
Min 
Piping 
Length 
(m) 
Max 
Piping 
Length 
(m) 
Additional 
Refrigerant 
(g/m) 
Piping 
length for 
add. Gas 
(m) 
LE9NKD 
3/8”   1/4” 
15 
20 
LE12NKD  3/8”  1/4” 
15 
20 
10.1.3   Indoor/Outdoor Unit Installation 
Diagram 
*This illustration is for explanation purposes only. 
 The indoor unit will actually face a different way. 