37 
 
14.1.2  Relationship between the condition of the air conditioner and pressure and electric 
current 
 
Cooling Mode 
Heating Mode 
Condition of the  
air conditioner 
Low Pressure 
High 
Pressure 
Electric current 
during 
operation 
Low Pressure 
High 
Pressure 
Electric current 
during operation 
Insufficient 
refrigerant 
(gas leakage) 
 
 
 
 
 
 
Clogged capillary 
tube or 
strainer 
 
 
 
 
 
 
Short circuit in the 
indoor unit 
 
 
 
 
 
 
Heat radiation 
deficiency 
of the outdoor unit 
 
 
 
 
 
 
Inefficient 
compression 
 
 
 
 
 
 
• Carry out the measurement of pressure, electric current, and temperature fifteen minutes after an operation is 
started. 
 
14.2  Breakdown Self Diagnosis Function 
14.2.1  About Self Diagnosis 
When the air-conditioner is stopped due to malfunction detected by itself, the operation can be restarted using AUTO 
Switch on the indoor unit. In forced operation, the frequency for compressor and fan speed can not be changed and 
the signal receiving sound is different. 
Normal Operation ON: “pep” 
Forced Operation ON: “pep”, “pep”, “pep”, “pep” 
Stop: “pep” 
Note: Refer to the Diagnosis Code Table for the malfunction when forced operation is not available.
 
14.2.2  Display of Error Code 
1. Keeping the CHECK button on the remote controller depressed for 5 seconds, error code ranging fromH11 to H99 
can be displayed on the remote controller. 
2. The error code is changed and diagnosis signal is transmitted to the indoor unit by pressing the Temp Up button on 
the remote control. 
3. When the malfunction of the air-conditioner matches the error code on the remote control, four beeps can be heard 
from the indoor unit and the operation indicator will light up. 
4. Keep the CHECK button depressed continuously for 5 seconds to cancel the diagnosis function. 
 
 
 
38 
14.2.3  Error Codes Table 
 
 
Code
Abnormality/Protection
Judgment
Check
Emergency
Operation
H00
Normal
H11
Indoor/Outdoor abnormal
communication
>1 minute after starting
operation
Connecting cable,
Indoor/outdoor PCB
H14
Indoor intake air temp sensor
abnormality
-
Intake air temperature
sensor(defected or
disconnected)
×
H15
Outdoor compressor
tempearture sensor abnormality
Continue for 5 sec.
Compressor tempeature
sensor(defected or
disconnected)
×
H16
Outdoor Current Transformer
open circuit
-
Outdoor PCB, IPM module
×
H19
Indoor fan motor mechanism
lock
-
Indoor PCB, fan motor
×
H23
Indoor heat exchanger
temperature A sensor
abnormality
Continue for 5 sec.
Heat exchanger
temperature
sensor(defected or
disconnected)
H27
Outdoor air temperature sensor
abnormality
Continue for 5 sec.
Outdoor temperature
sensor(defected or
disconnected)
H28
Outdoor heat exchanger
temperature sensor abnormality
Continue for 5 sec.
Outdoor heat exchanger
sensor(defected
disconnected)
H30
Discharge temperature sensor
abnormality
Continue for 5 sec.
Discharge temperature
sensor(defected or
disconnected)
×
H33
Incorrect connection of
Indoor/Outdoor cable
-
Indoor/outdoor supply
voltage
×
H97
Outdoor fan motor lock
Twice within 30 minutes Outdoor fan motor
×
H98
Indoor high pressure protection -
Air filter dirty
Air circulation short circuit
-
H99
Indoor heat exchanger anti-
freezing protection
Indoor heat exchanger
freezing
Insufficient refrigerant
Air filter dirty
-
F11
Cooling/Heating cycle
changeover abnormality
4 times occurrence
within 30 minutes
4-way valve
V-coil
×
F90
PFC control
4 times occurrence
within 20 minutes
Voltage at PFC
×
F91
Refrigeration cycle abnormality
2 times occurrence
within 20 minutes
No refrigerant(3-way valve is
closed)
×
F93
Compressor abnormality
4 times occurrence
within 20 minutes
Compressor
×
F95
Cool high pressure protection
4 times occurrence
within 20 minutes
Outdoor refrigeration cycle
×
F96
IPM overheating protection
-
Excessive refrigerant
Improper heat radiation
IPM
×
F97
Outdoor compressor
overheating protection
4 times occurrence
within 20 minutes
Insufficient refrigerant
Compressor
×
F98
Total running current protection
3 times occurrence
within 20 minutes
Excess refrigerant
Improper radiation
×
F99
Outdoor Peak Current
Protection Control
4 times occurrcnce
continuously within 30
minutes
Outdoor PCB
IPM
Compressor
×
39 
15.  Technical Data 
15.1  Operation Characteristics 
15.1.1  CS-LE9NKD CU-LE9NKD 
Cooling Characteristic at Different Outdoor Air Temperature 
 
 
40 
Cooling Characteristic at Different Piping Length 
 
Page of 55