NOTE: 
 
OFF Timer and OFF- ON Timer can only be set during the operation; 
 
Timer setting can operate only once. 
 
If the OFF/ON button on the remote control or the AUTO Switch on the indoor unit is pressed, the timer setting 
will be cancelled. 
 
If Auto Restart Control occurs, timer setting will be cancelled. 
 
During the operation, if the ON Timer or ON-OFF Timer is set, the operation will be stopped. 
11.3.10  About Cursor Key Which Points To 
OFF
”    
On Remote Control 
When the ON/OFF button on the remote control is pressed, the cursor key which points to “OFF” will appear or disappear to 
indicate the ON/OFF status of the air conditioner. 
 
 
 
For some reason (Ex. The signal of the remote control does not reach the signal receiver of the indoor unit.), the display of the 
remote control will not correspond with the actual ON/OFF status of the indoor unit: 
 
1. 
The air conditioner is running but the cursor key which points to “OFF” appears. The air conditioner can be stopped with 
any button (Except for “ON/OFF”, “TIMER A”, “TIMER B”) pressed. 
2. 
The air conditioner is on standby, but the cursor key which points to “OFF” disappears. The air conditioner can be started 
with any button (Except for “ON/OFF”, “TIMER A”, “TIMER B”) pressed.
 
12.  Operation Control 
12.1  Basic Function 
12.1.1  Internal Setting Temperature 
Once the operation starts, remote control setting temperature will be taken as base value for temperature shifting 
processes. These shifting processes are depending on the air conditioner settings and the operation environment. 
The final shifted value will be used as internal setting temperature and it is updated continuously whenever the 
electrical power is supplied to the unit. 
  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Remote Control Setting Temp. (16
~30
)
 
Auto Operation Mode Shifting 
Outdoor Air Temperature Shifting 
Setting Temperature Limit Checking
(16℃~30℃)
 
Setting Temperature Limit Checking ( Min:16 
; Ma
x:33
)
 
Internal Setting Temperature 
AUTO 
HEAT 
COOL 
DRY 
AUTO 
HEAT 
COOL 
DRY 
Powerful Temperature Limit Checking
  
Fan Speed Shifting 
Dry mode Shifting 
Operating Shifting 
Cooling/Heating Shifting 
26 
12.1.2  Cooling Operation  
12.1.2.1 
Thermostat control 
• Compressor is OFF when Intake Air Temperature – Internal Setting Temperature < -1.5
 
• Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature – Internal Setting Temperature > 
Compressor OFF point +0.5K. 
 
12.1.3  Soft Dry Operation 
12.1.3.1 
Thermostat control 
• Compressor is OFF when Intake Air Temperature – Internal Setting Temperature < -2.5
 
• Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature – Internal Setting Temperature > 
Compressor OFF point +0.5K. 
      
 
12.1.4  Heating operation 
12.1.4.1 
Thermostat control 
• Compressor is OFF when Intake Air Temperature – Internal Setting Temperature > +2.0
 
• Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature – Internal Setting Temperature< 
Compressor OFF point -0.5K. 
 
27 
12.1.5  Automatic Operation 
• Once AUTO mode is selected, operation mode is determined by set temperature of remote control and indoor 
intake temperature. 
1
st
 judgment 
      
JUDGE CONDITION 
REFERANCE MODE  
If indoor intake temp – Remote control 
temp setting 
 +2  
Cool mode 
If  -2 
 indoor intake temp. – Remote 
control Temp. setting 
 +2  
Dry mode 
If indoor intake temp. – Remote control 
temp. setting < -2 
Heat mode 
 
 
2
nd
 & following judgment (every 10 minutes after 1
st
 judgment)  
 
JUDGE CONDITION 
REFERANCE  MODE 
If indoor intake temp – Remote control temp 
setting 
 +3  
  Cool mode if previously    is Cool / 
Heat mode 
  Dry mode if previously is Dry mode 
If  -2 
 indoor intake temp. – Remote control 
Temp. setting < +3  
Maintain current mode 
If indoor intake temp. – Remote control 
temp. setting < -2 
Heat mode 
  
 
Note:  
  When auto judgment has been made to operate in Cool mode, the unit will enter  different states according to 
outdoor temperature conditions:-  
Outdoor Temp. Condition 
Air Conditioner Status 
If outdoor temperature
 16
 
Cooling operation 
If outdoor temperature <16
 
Compressor OFF and standby. 
  During sampling and making judgment, POWER LED will blink.  
  When judgment has been made, POWER LED will stop blinking and ON.  
  During AUTO mode operation, horizontal louver direction
 
and FAN speed can be selected by remote control 
 
12.2  Indoor Fan Motor Operation 
A.  Basic Rotation Speed 
i. 
Manual Fan speed 
Fan motor’s number of rotation is determined according to remote control setting. 
 
Intake temp.- setting temp.
 
DRY 
 
COOL 
 
HEAT 
 
-6 -5  -4  -3  -2  -1  0    1   2   3   4   5   6
 
MAINTAIN 
CURRENT MODE 
COOL/DRY 
 
HEAT 
 
Intake temp.- setting temp.
 
-6 -5  -4  -3   -2  -1  0   1   2   3   4   5   6
 
28 
Remote control 
QUIET 
Model 
Tab 
Hi 
Me+ 
Me 
Me- 
Lo 
Qlo 
COOLING(rpm) 
1060 
980 
900 
820 
740 
560 
CS-LE9NKD 
HEATING(rpm) 
1020 
880 
820 
760 
700 
600 
COOLING(rpm) 
1150 
1060 
960 
860 
760 
560 
CS-LE12NKD 
HEATING(rpm) 
1100 
1030 
970 
910 
850 
700 
 
ii. 
Auto Fan Speed (Cooling, Soft Dry Mode) 
According to room temperature and setting temperature, indoor fan speed is determined automatically. 
The indoor fan will operate according to pattern below. 
 
Fan speed
Higher
Medium
Lower
A          b              c              d                e               f             g            h           a              b
 
 
B.  Feedback control 
• Immediately after the fan motor started, feedback control is performed once every second. 
• During fan motor on, if fan motor feedback 2550 rpm or < 50 rpm continue for 10 seconds, then fan motor error 
counter increases, fan motor then stops and restarts. If the fan motor counter becomes 7 times, then H19 – fan motor 
error is detected. Operation stops and cannot on back. 
12.3  Outdoor Fan Motor Operation 
Outdoor fan motor is operated with one fan speed only. It starts when compressor starts operation and it stops 30 
seconds after compressor stops operation. 
30 s
Compressor
Outdoor Fan
ON
ON
OFF
OFF
ON
 
12.3.1  Vertical Airflow 
 
Airflow Direction 
1. Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the angles as stated 
above. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature. When the air 
conditioner is stopped using remote control, the vane will shift to close position. 
2. Manual vertical airflow direction can be set using remote control. The angels of the vane are as stated above.  When the air 
conditioner is stopped using remote control, the vane will shift to close position. 
* Above angle data is for reference only. 
12.3.2  Horizontal Airflow 
The horizontal airflow direction louvers can be adjusted manually by hand. 
 
1
2
3
4
5
10°
21°
31°
40°
50°
Normal
Powerful
10°
21°
31°
40°
50°
Normal
Powerful
Normal
22°
35°
50°
60°
Powerful
31°
40°
48°
58°
68°
Normal
Powerful
7°,8°,36° 
Manual
7°,8°,33°,45°(Beginning of POWERFUL mode) 
10°-50°
6°,35°(Beginning of POWERFUL mode) 
12°
Operating Mode
Cooling
Soft dry
12°
Heating
Manual
Auto
Manual
Auto
Auto
Page of 55
Display

Click on the first or last page to see other CS-LE9NKD / CS-LE12NKD / CU-LE9NKD / CU-LE12NKD service manuals if exist.