7.
Indoor Fan Speed Control
Fan
Voltage
Voltage
Cooling
Heating
Speed
Supply to
Supply to
Soft
Remarks
Remarks
No.
DC (V)
DC (V)
Manual
Auto
Dry
Manual
Auto
CS-G95KE
CS-G125KE
0
OFF
OFF
OFF
OFF
OFF
  • 
Hot Start Control
1
2
15.6
16.3
SLo
  • 
Deodorizing control
  • 
Sleep Mode (Soft Dry)
  • 
SLo: Hot Start Control
3
16.3
17.6
Lo
-
  • 
Auto operation mode
judgement
  • 
Quiet operation
4
17.6
20.3
5
17.9
21.7
  • 
Lo
-
:
Hot Start Control
Sleep Mode
Anti Cold Draft Control
Thermo OFF
6
18.4
23.4
Lo
  • 
Sensible Heat Control (Lo)
  • 
On Timer preparatory
operation + Auto Fan
  • 
Sleep mode (Cooling)
7
18.7
24.0
  • 
Sensible Heat Control (Me
-
)
Auto
Fan
(Min.)
8
19.3
24.4
  • 
Manual Lo Fan + Powerful
Lo
  • 
On Timer preparatory
operation + Auto Fan
9
20.1
26.4
  • 
Sensible Heat Control +
Auto Fan
10
21.4
27.1
Me
-
  • 
Sensible Heat Control (Me)
  • 
Manual Lo Fan + Powerful
11
22.0
27.8
Auto
Fan
  • 
Sensible Heat Control +
Auto Fan
  • 
Auto Fan (min) + Powerful
12
22.7
28.3
  • 
Manual Me
-
Fan + Powerful
13
23.0
28.3
Auto
Fan
  • 
Sensible Heat Control
(Me
+
)
  • 
Auto Fan + Powerful
  • 
Sensible Heat Control +
Auto Fan
Me
-
14
23.1
28.4
Me
  • 
Temporary Operation
15
23.5
28.8
Auto
Fan
  • 
Auto Fan + Powerful
Auto
Fan
(Max.)
  • 
Manual Me
-
Fan + Powerful
16
24.3
29.1
  • 
Manual Me Fan + Powerful
  • 
Sensible Heat Control (Hi)
17
25.0
29.8
  • 
Auto Fan + Powerful
Me
  • 
Temporary Operation
18
25.3
29.8
Me
+
19
26.0
30.1
  • 
Manual Me Fan + Powerful
20
26.4
30.5
  • 
Manual Me
+
Fan + Powerful
21
26.4
30.7
22
26.5
30.8
Hi
  • 
Test Run
23
27.3
31.1
Me
+
24
27.6
31.5
  • 
Manual Hi Fan + Powerful
25
28.0
31.9
  • 
Manual Me
+
Fan + Powerful
26
28.3
32.3
27
29.0
32.6
  • 
SHi: Maximum Capacity
Operation
  • 
Auto Fan (max) + Powerful
28
29.3
32.6
29
29.8
33.0
30
29.8
33.4
SHi
  • 
Manual Hi Fan + Powerful
  • 
On Timer preparatory
operation + Manual Fan +
Powerful
  • 
Test Run
31
32.7
36.9
  • 
SSHi: Maximum Capacity
Operation
33
CS-G95KE CU-G95KE / CS-G125KE CU-G125KE
(a) Cooling Automatic Fan Speed
The Automatic Fan Speed for cooling operation is shown as below:
(i) When Automatic Fan Speed is selected
(ii) When Automatic Fan Speed and Powerful Mode are selected
Note:
The Fan Speed will change every 10 seconds and it will be repeated from a to h every 80 seconds.
(b) Heating Automatic Fan Speed
The Automatic Fan Speed for heating operation is shown below:
  • 
When the Automatic Fan Speed is selected, the Fan Speed will change every 10 seconds from Fan Speed No.7 to No.15
depending on indoor heat exchanger temperature. Each time the Fan Speed will move 1 rank up or down
  • 
When Automatic Fan Speed and Powerful Mode are selected, the Fan Speed will change for every 10 seconds from Fan
Speed No. 11 to No. 27 depend on heat exchanger temperature. Each time the Fan Speed will move 1 rank up or down.
34
S-G95KE CU-G95KE / CS-G125KE CU-G125KE
8.
Outdoor Fan Control
(c) Cooling Operation at SHi Speed
During Cooling operation, Indoor Fan speed is set at SHi when the following conditions occur:
  • 
Outside air temperature is 30°C or above
  • 
Compressor operates at 50Hz (CU-G95KE) or 70Hz (CU-G125KE) and above
  • 
Remote control setting fan speed is High
  • 
Indoor intake air temperature is 24°C or above
  • 
Remote control setting temperature is 16°C
  • 
Within 30 minutes after start of operation
(d) Heating Operation at SSHi Speed
During Heating operation, Indoor Fan speed is set at SSHi when the following conditions occur:
  • 
Heating operation for 2 hours or more
  • 
When remote control setting fan speed is High
  • 
Indoor intake air temperature is 17°C or above and less than 23°C
  • 
Outdoor air temperature is below 4°C
  • 
Remote control setting temperature is 30°C
  • 
Compressor operates at 71Hz (CU-G95KE) or 90Hz (CU-G125KE) and above
  • 
Airflow Direction is set at Manual
  • 
Outdoor fan motor is controlled with 1 speed only. Fan is in operation when the compressor starts operation and stops 30
seconds after compressor stops operation.
35
CS-G95KE CU-G95KE / CS-G125KE CU-G125KE
9.
Airflow Direction
A. Vertical Airflow Direction
  • 
Vane angle setting
Operation
Vane angle
1
2
3
4
5
Heating
Airflow direction auto
Indoor heat exchanger temperature
C
33°
B
70°
A
15°
Airflow direction manual
-
13°
33°
46°
57°
70°
Cooling
Airflow direction auto
-
7° ~ 36°
Anti-dew formation control
11° ~ 25°
Airflow direction manual
-
15°
25°
33°
41°
Anti-dew formation control
11°
15°
18°
22°
25°
Soft Dry
Airflow direction auto
-
3° ~ 33°
Anti-dew formation control
11° ~ 25°
Airflow direction manual
-
18°
25°
33°
Anti-dew formation control
11°
15°
18°
22°
25°
Fan
Airflow direction auto
7° ~ 36°
Airflow direction manual
15°
25°
33°
41°
Stop
143°
  • 
Setting angle
36
S-G95KE CU-G95KE / CS-G125KE CU-G125KE