Panasonic CS-G95KE / CS-G125KE / CU-G95KE / CU-G125KE Service Manual ▷ View online
1
Features
2
2
Functions
3
3
Product Specifications
8
4
Dimensions
12
5
Refrigeration Cycle Diagram
14
6
Block Diagram
15
7
Wiring Diagram
16
8
Operation Details
18
9
Operating Instructions
48
CS-G95KE CU-G95KE
CS-G125KE CU-G125KE
CS-G125KE CU-G125KE
10 Installation Instructions
72
11 Servicing Information
81
12 Technical Data
94
13 Exploded View
97
14 Replacement Parts List
98
15 Exploded View
99
16 Replacement Parts List
100
17 Electronic Parts List
101
18 Electronic Circuit Diagram
103
Room Air Conditioner
CONTENTS
Page
Page
Order No: MAC0010056C2
•
Product
−
Powerful Mode for quick cool/heat
−
Compressor operating frequency control to maintain
desired room temperature
desired room temperature
−
Automatic Restart after power failure
−
Washable front panel
−
Power Monitor Display
−
Standby Control
−
High COP (new compressor and indoor heat exchanger)
−
Vertical and Horizontal Airflow Auto Swing
−
Auto change over of Automatic Operation mode
−
Self illuminating Remote Control
−
Catechin Air Purifying Filter
(To trap dust, tabacco smoke and tiny particles in the
room; to prevent the growth of bacteria and viruses
trapped in this filter)
(To trap dust, tabacco smoke and tiny particles in the
room; to prevent the growth of bacteria and viruses
trapped in this filter)
−
Deodorizing Filter
•
Serviceability
−
Self diagnosis
−
Forced
Cooling
and
Heating
operation
at
rated
frequency
•
Quality Improvement
−
High power supply voltage protection
−
Low power supply voltage protection
−
Gas leakage detection
1 Features
2
S-G95KE CU-G95KE / CS-G125KE CU-G125KE
2 Functions
Remote Control
Operation OFF / ON
OFF / ON
I
Room Temperature Setting
TEMP.
Operation Mode Selection
•
a
Automatic Operation Mode
•
HEAT
Heating Operation Mode
•
COOL
Cooling Operation Mode
•
DRY
Soft Dry Operation Mode
•
FAN
Fan Operation Mode
Time / Timer Setting
• Hours and minutes setting.
Clock Setting
• Current time setting.
Sleep Mode Operation OFF / ON
SLEEP
Indoor Fan Speed Selection
FAN SPEED
•
h j k
Low
l
•
h j k
Medium
–
ll
•
h j k
Medium
lll
•
h j k
Medium
+
llll
•
h j k
High
lllll
•
AUTO FAN
Automatic Fan Speed
Airflow Direction Control
• 24-hour, OFF / ON Real Timer Setting.
TIMER
ON OFF
ON OFF
Timer Operation Selection
SET
CANCEL
CANCEL
Timer Operation Set / Cancel
• ON Timer and OFF Timer setting and
cancellation.
CLOCK
• Vertical Airflow Direction Control
Automatic Control
Manual Control
• Horizontal Airflow Direction Control
Automatic Control
Manual Control
Powerful Mode Operation
POWERFUL
• Temperature Setting (16°C to 30°C)
Self illuminating
button
AIR SWING
AUTO
AUTO
∨
∧
WIDE / SPOT
WIDE /
SPOT
SPOT
•
WIDE Horizontal Airflow
Direction
Direction
•
SPOT Horizontal Airflow
Direction
Direction
POWER SLEEP TIMER
P O W E R
MONITOR
POWERFUL
LOW
HIGH
POWER SLEEP TIMER
P O W E R
MONITOR
POWERFUL
LOW
HIGH
3
CS-G95KE CU-G95KE / CS-G125KE CU-G125KE
Indoor Unit
Power Monitor Display
*
*
*
*
*
• Lights up during compressor operation.
Airflow Direction Control
*
*
*
*
*
Automatic Switch
• Press for < 5s to operate Automatic
Operation Mode.
(Used when the remote control cannot be used.)
(Used when the remote control cannot be used.)
• Press continuosly for 5s or < 8s to
operate Forced Cooling Operation at
compressor rated frequency:
50 Hz (CS-G95KE); 70 Hz (CS-G125KE)
compressor rated frequency:
50 Hz (CS-G95KE); 70 Hz (CS-G125KE)
• Press continuosly for 8s or < 11s to
operate Forced Heating Operation at
compressor rated frequency:
71 Hz (CS-G95KE); 90 Hz (CS-G125KE)
compressor rated frequency:
71 Hz (CS-G95KE); 90 Hz (CS-G125KE)
• Press continuosly for 11s or < 16s to
switch over Remote Control A
↔
B Switch
Signal.
• Press continuosly for 16s or < 21s to
switch OFF / ON Remote Control Re-
ceiving Sound and H14 Abnormality
Detection Mode.
ceiving Sound and H14 Abnormality
Detection Mode.
AUTO
OFF / ON
Operation Indication Lamps (LED)
•
POWER
(Green) ........ Lights up in opera-
tion, blinks in Auto-
matic Operation
Mode judging and
Hot Start operation.
matic Operation
Mode judging and
Hot Start operation.
•
TIMER
(Orange) ....... Lights up in Timer
Setting.
Blinks in Self Diag-
nosis Control.
Blinks in Self Diag-
nosis Control.
•
SLEEP
(Orange) ........ Lights up in Sleep
Mode Operation.
•
POWERFUL
(Orange) .. Lights up when
Powerful Mode is
selected.
selected.
Sleep Operation Mode
*
*
*
*
*
Operation Mode
• Automatic, Heating, Cooling, Soft Dry
and Fan Operation.
FOR ALL OPERATIONS
Automatic Restart Control
*
*
*
*
*
• Operation is restarted after power failure
at previous setting mode.
Timer Operation
*
*
*
*
*
Powerful Mode
*
*
*
*
*
• For quick cooling or heating.
Indoor Fan Speed Control
*
*
*
*
*
4
S-G95KE CU-G95KE / CS-G125KE CU-G125KE