Panasonic CS-F18DTE5 / CU-L34DBE5 Service Manual ▷ View online
2.1.1. Easier maintenance and cleaning
• Anti-mould long life air filter.
• 3-direction pipe lead-out.
• 3-direction pipe lead-out.
2.1.2. Wide air discharge, comfortable
control
• Wide-angle airflow - 100 degrees horizontal.
• Auto swing louver.
• Auto swing louver.
2.2. Outdoor unit
2.2.1. Flexible installation in smaller
spaces
• Space-saving outdoor unit with the improvement of the
outdoor unit fan makes it possible to install the outdoor unit
into a smaller space where the conventional model cannot
be installed.
into a smaller space where the conventional model cannot
be installed.
• Long pipe design with a maximum piping length of 50m.
• Additional charging of refrigerant are not required for 30m
• Additional charging of refrigerant are not required for 30m
of pipe length.
• Flexible 4-way piping.
• Centralized drain method gather multiple outdoor units’
drain pipes into a single drain pipe to make installation
easier and also improve appearance.
easier and also improve appearance.
• Side-by-side continuous installation is possible even for
outdoor units with different capacities.
2.2.2. Quiet, efficient design
• A host of silencing technologies achieves super-quiet
operation.
• The noise-suppressing winglet fan is a result of new
research into vane design theory. The unique curved shape
suppresses the generation of vortexes, thus reduces air
flows noise.
suppresses the generation of vortexes, thus reduces air
flows noise.
• Operating efficiency is improved and energy consumption is
reduced.
2.2.3. Low ambient cooling operation
• The unit can set for cooling even when the outdoor
temperature drops to -5°C for regular cooling condition.
• However, cooling operation at -15°C is possible in non-
residential computer rooms, etc., where the temperature is
not less than 21°C and humidity is not more than 45%.
not less than 21°C and humidity is not more than 45%.
2 Features
2.1. Ceiling type
5
CS-F18DTE5 CU-L34DBE5 /
2.3. A brand-new control method
1. Twin operation
• Simultaneous air conditioning of wide spaces and corners is possible. Indoor units of same horsepowers can even be used
in combination.
• Master unit and slave-units can be set automatically in twin systems. No address setting is necessary.
• Multiple indoor units can be operated simultaneously with a single remote control. Note that individual operation is not
• Multiple indoor units can be operated simultaneously with a single remote control. Note that individual operation is not
possible.
6
CS-F18DTE5 CU-L34DBE5 /
2.4. Wired Remote Control
1. The new design includes an easily-visible red pilot lamp. The power can be turned on and off at a single touch, without opening
the cover.
2. Has a build-in thermistor, allowing indoor temperature detection in accordance with indoor conditions by switching with main unit
thermistor.
3. Twin non-polar wires make installation work easy. (10 m cable supplied as accessory.)
2.5. Wireless Remote Control
1. New design with compact size. (Operation range within approximately 8 m.)
2. Built-in timer with OFF/ON timer setting (within 24 hours)
Wired
Wireless
CZ-RD513C
CZ-RL513T
NOTE: Both of the above remote control is packed separately from the indoor unit.
7
CS-F18DTE5 CU-L34DBE5 /
2.6. Group Control Equipment
Wired
remote
control
Group control by one remote
control
control
• All air conditioner units are
controlled as a whole by remote
control.
control.
• All indoor units operate in the
same mode.
[Remote side]
• Optional wired remote
control CZ-RD513C
[Local side]
Not needed
Not needed
Twin remote control separate
control
control
• Each indoor unit can be operated
by either one of the two remote
control.
control.
• Apart from timer setting time,
displays for two remote control are
identical.
identical.
• Last button pressed has priority
(main or slave is set at remote
control unit).
control unit).
[Remote side]
• Optional wired remote
control
[Local side]
• Optional wired remote
control CZ-RD513C
Common
control
Common control / group
• Operation is possible using either
wired or wireless remote control
unit.
unit.
• Last button pressed has priority.
• Optional wired remote
control and wireless
remote control
remote control
Wired CZ-RD513C
Wireless CZ-RL513T
8
CS-F18DTE5 CU-L34DBE5 /
Click on the first or last page to see other CS-F18DTE5 / CU-L34DBE5 service manuals if exist.