DOWNLOAD Panasonic CS-F18DTE5 / CU-L34DBE5 Service Manual ↓ Size: 16.38 MB | Pages: 127 in PDF or view online for FREE

Model
CS-F18DTE5 CU-L34DBE5
Pages
127
Size
16.38 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-f18dte5-cu-l34dbe5.pdf
Date

Panasonic CS-F18DTE5 / CU-L34DBE5 Service Manual ▷ View online

2.1.1. Easier maintenance and cleaning
 • Anti-mould long life air filter.
 • 3-direction pipe lead-out.
2.1.2. Wide air discharge, comfortable
control
 • Wide-angle airflow - 100 degrees horizontal.
 • Auto swing louver.
2.2. Outdoor unit
2.2.1. Flexible installation in smaller
spaces
 • Space-saving outdoor unit with the improvement of the
outdoor unit fan makes it possible to install the outdoor unit
into a smaller space where the conventional model cannot
be installed.
 • Long pipe design with a maximum piping length of 50m.
 • Additional charging of refrigerant are not required for 30m
of pipe length.
 • Flexible 4-way piping.
 • Centralized drain method gather multiple outdoor units’
drain pipes into a single drain pipe to make installation
easier and also improve appearance.
 • Side-by-side continuous installation is possible even for
outdoor units with different capacities.
2.2.2. Quiet, efficient design
 • A host of silencing technologies achieves super-quiet
operation.
 • The noise-suppressing winglet fan is a result of new
research into vane design theory. The unique curved shape
suppresses the generation of vortexes, thus reduces air
flows noise.
 • Operating efficiency is improved and energy consumption is
reduced.
2.2.3. Low ambient cooling operation
 • The unit can set for cooling even when the outdoor
temperature drops to -5°C for regular cooling condition.
 • However, cooling operation at -15°C is possible in non-
residential computer rooms, etc., where the temperature is
not less than 21°C and humidity is not more than 45%.
2 Features
2.1. Ceiling type
5
CS-F18DTE5 CU-L34DBE5 /
2.3. A brand-new control method
 1. Twin operation
 • Simultaneous air conditioning of wide spaces and corners is possible. Indoor units of same horsepowers can even be used
in combination.
 • Master unit and slave-units can be set automatically in twin systems. No address setting is necessary.
 • Multiple indoor units can be operated simultaneously with a single remote control. Note that individual operation is not
possible.
6
CS-F18DTE5 CU-L34DBE5 /
2.4. Wired Remote Control
 1. The new design includes an easily-visible red pilot lamp. The power can be turned on and off at a single touch, without opening
the cover.
 2. Has a build-in thermistor, allowing indoor temperature detection in accordance with indoor conditions by switching with main unit
thermistor.
 3. Twin non-polar wires make installation work easy. (10 m cable supplied as accessory.)
2.5. Wireless Remote Control
 1. New design with compact size. (Operation range within approximately 8 m.)
 2. Built-in timer with OFF/ON timer setting (within 24 hours)
Wired
Wireless
CZ-RD513C
CZ-RL513T
NOTE: Both of the above remote control is packed separately from the indoor unit.
7
CS-F18DTE5 CU-L34DBE5 /
2.6. Group Control Equipment
Wired
remote
control
Group control by one remote
control
 • All air conditioner units are
controlled as a whole by remote
control.
 • All indoor units operate in the
same mode.
[Remote side]
 • Optional wired remote
control CZ-RD513C
[Local side]
Not needed
Twin remote control separate
control
 • Each indoor unit can be operated
by either one of the two remote
control.
 • Apart from timer setting time,
displays for two remote control are
identical.
 • Last button pressed has priority
(main or slave is set at remote
control unit).
[Remote side]
 • Optional wired remote
control
[Local side]
 • Optional wired remote
control CZ-RD513C
Common
control
Common control / group
 • Operation is possible using either
wired or wireless remote control
unit.
 • Last button pressed has priority.
 • Optional wired remote
control and wireless
remote control
Wired CZ-RD513C
Wireless CZ-RL513T
8
CS-F18DTE5 CU-L34DBE5 /
Page of 127
Display