7
1. Cooling capacities are based on indoor temperature of 27
°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35
°C D.B. (95°F D.B.), 24°C D.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20
°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6
°C W.B. (42.8°F W.B.)
Note
• Specifications are subject to change without notice for further improvement.
ITEM
UNIT
Power Source (Phase, Voltage, Cycle)
ø
Single
V
220 - 230
Hz
50
Input Power
kW
Cooling: 2.54 - 2.58
Heating: 2.53 - 2.56
Starting Current
A
65
Running Current
A
Cooling: 12.3 - 12.2
Heating: 12.2 - 12.2
Power Factor
%
Cooling: 94 - 92
Heating: 94 - 91
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
*Maximum over current protection
A
15.8
Number of Core
3 (2.5mm
2
)
Power Cord
Length
m
1.9
Thermostat
Protection Device
Inner Protector
8
3 Features
• High efficiency.
• Compact design.
• Wider range of horizontal discharge air.
• Air Filter with function to reduce dust and smoke.
• Automatic air swing and manual adjusted by Remote Control for horizontal and vertical airflow.
• Long installation piping up to 25 meter.
• Quality Improvement
- Random auto restart after power failure for safety restart operation.
- Gas leakage detection.
- Prevent Compressor reverse cycle.
- Inner protector to protect Compressor.
- Noise prevention during soft dry operation.
- Anti-dew formation control (Cooling & Soft Dry).
- Overload Protection Control (Heating).
- Outdoor Fan Control.
- Compressor High Pressure Control.
• Operation Improvement
- Quiet mode to provide quiet operation.
- Powerful mode to reach the desired room temperature quickly.
- 24-hour timer setting.
- Patrol sensor automatically detect the air quality. When the air quality is unsatisfactory, e-ion operation will start automatically.
- e-ion Air purifying System provides clean air by producing negative ions to attract dust which will then be captured at the pos-
itively charged e-ion filters.
• Serviceability Improvement
- Removable and washable Front Panel.
9
4 Location of Controls and Components
4.1.
Product Overview
4.1.1.
Indoor Unit
4.1.2.
Outdoor Unit
4.1.3.
Remote Control
10
5 Dimensions
5.1.
Indoor Unit