DOWNLOAD Panasonic CS-A18DKD / CU-A18DKD / CS-A24DKD / CU-A24DKD Service Manual ↓ Size: 13.92 MB | Pages: 86 in PDF or view online for FREE

Model
CS-A18DKD CU-A18DKD CS-A24DKD CU-A24DKD
Pages
86
Size
13.92 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
cs-a18dkd-cu-a18dkd-cs-a24dkd-cu-a24dkd.pdf
Date

Panasonic CS-A18DKD / CU-A18DKD / CS-A24DKD / CU-A24DKD Service Manual ▷ View online

 d. Vertical airflow direction can be adjusted using remote control during Ionizer individual operation.
 e. During Ionizer individual operation, operated mode (Auto, Cool, Dry, Heat) can be activated by turning on the OFF/ON
operation button. (2
→ 4)
 f. 
If power failure occur during Ionizer individual operation, after power resume, Ionizer operation will be activated immediately.
 g. When the Ionizer circuit feedback process error occur for 24 times (about 11hr 30 min.), Ionizer and Air Circulation
operations will turn off with ION LED blinks continuously.
(For details, please refer to Ionizer Error detection control)
 2. Operation mode & Ionizer operation.
 a. When air-conditioner unit is at “ON” condition and ION operation button at the remote control is pressed, the Ionizer
operation will turn on. ION & Power LED will illuminate. (3
→ 4)
 b. Ionizer operation stops when:
 • ION operation button is press again.
 • Stopped by OFF/ON operation button.
 • Timer OFF activates.
 • Ionizer circuit feedback signal shows error.
 c. Ionizer operation status is not memorised when the air conditioner has been switched off. The air-conditioner will operate
without ionizer operation when it is turned on again. However, if power failure occurs during Ionizer operation together with
Cooling operation, air-conditioner will start to operate at Cooling operation with Ionizer operation when the power is
resumed.
8.12.2. Error Detection Control
 • The error detection control is to inform user that error occurs at ionizer system and repairing job will be needed.
 • There are two types of error detection control:
a. When Ionizer is ON
 − If ionizer feedback = Lo for 24 times within 11hr 30min, ION LED blinks continuously.
b. When ionizer is OFF
 − If ionizer feedback = Hi, ION LED blinks continuously.
 • During ionizer at breakdown condition, if ionizer feedback voltage = Lo (become normal), ION LED will stop blinking.
 • The error detection control can be reset by:
i) Pressing the OFF/ON operation button to switch the operation OFF.
ii) Pressing the Auto Operation button to force the operation OFF.
iii) Setting the OFF Timer to stop the operation (Not applicable when ionizer is OFF).
8.13. Timer Control
8.13.1. Delay ON Timer
 • When the Delay ON Timer is set by using the remote control, the unit will start to operate slightly before the set time, so that
the room will reach nearly to the set temperature by the set time.
 • For Cooling and Soft Dry operation, the operation will start 15 minutes before the set time.
 • For Heating operation, the operation will start 30 minutes before the set time.
 • For Automatic operation, the indoor fan will operate at SLo speed for 20 seconds, 15 minutes before the set time to detect the
intake air temperature to determine the operation mode. The operation indication lamp will blink at this time.
8.13.2. Delay OFF Timer
 • When the Delay OFF Timer is set by using the remote control, the unit will stop operate according to the desired setting.
Notes:
 1. By pressing OFF/ON operation button, the Delay ON Timer or Delay OFF Timer setting will not be cancelled.
 2. To activate the previous timer setting, press SET/CANCEL button once again.
33
CS-A18DKD CU-A18DKD / CS-A24DKD CU-A24DKD
8.14. Random Auto Restart Control
 • If there is a power failure during operation, the air conditioner will automatically restart after 3 to 4 minutes when the power is
resumed.
 • It will start with previous operation mode and airflow direction.
 • If there are more than one air conditioner unit in operation and power failure occur, restart time for each unit to operate will be
decided randomly using 4 parameters:- intake air temperature, setting temperature, fan speed and air swing louver position.
 • This Random Auto Restart Control is not available when Timer is set.
 • This control can be omitted by open the circuit of JX2. (Refer Circuit Diagram)
8.15. Remote Control Signal Receiving Sound
 • Long beep sound will be heard when:-
 − Stopping the air conditioner using OFF/ON operation button.
 − Stopping the Quiet Mode.
 − Stopping the Powerful Mode.
 − Stopping the Ion Mode.
 • Short beep sound will be heard for other setting.
 • To switch off the beep sound:-
Press the “Auto Operation Button” (behind the front grille) continuously for 10 seconds or more (“beep” “beep” will be heard at
the 10th second). Repeat the above if you want to switch on the beep sound.
However, if the “Automatic Operation Button” has been pressed the Automatic operation will be activated. If you do not require
this operation, you may change it by using the remote control.
34
CS-A18DKD CU-A18DKD / CS-A24DKD CU-A24DKD
9 Operating Instructions
35
CS-A18DKD CU-A18DKD / CS-A24DKD CU-A24DKD
36
CS-A18DKD CU-A18DKD / CS-A24DKD CU-A24DKD
Page of 86
Display

Click on the first or last page to see other CS-A18DKD / CU-A18DKD / CS-A24DKD / CU-A24DKD service manuals if exist.