Panasonic CS-A18CKE / CU-A18CKE / CS-A24CKE / CU-A24CKE Service Manual ▷ View online

Vertical
direction
Select automatic / manual
Current time OK?  —> Setting : page 39
Start before ˙ON¨ time
Horizontal
direction
Fan speed
(air volume)
Direction / volume
Automatic Internal Function
Fast cooling/heating
Provide quiet operation
Air flow sound
Produce negative ion for fresh air
Provide negative 
ion during operation
Provide negative 
ion with FAN operation
If
Blinking
press twice
Air flow sound will reduce during operation
Air-conditioner
Air Flow
POWERFUL
QUIET
Operation
ON
Select
OFF
ON & OFF
Timer
TIMER
Operation
Set time
Set time
Set time
Confirm
cancel
Confirm
Confirm
or
or
Active every day
Still Blinking -
Call Service
Press button
Activate / Deactivate
Activate / Deactivate
Activate / Deactivate
Timer
Timer
COOL/DRY  : 15 min.
AUTO/HEAT  : 30 min.
Automatic
Super high
COOL
/DRY
Fan speed (air volume)
Set temperature
IONIZER
IONIZER
IONIZER
37
CS-A18CKE CU-A18CKE / CS-A24CKE CU-A24CKE
Vacuum
Wash
Dry
Wipe gently
Wash gently..   + dry
Filter cleaning see below
Open manually
Ionizer
REPLACE every 3 years!
Clean with 
cotton bud
Benzine / Thinner
Scouring
powder
Damaged –> replace!
Reinstall
DIRTY FILTERS cause: unpurified air, low cooling/heating capacity, more unpleasant smells,
higher energy consumption!
Indoor Unit
CARE & CLEANING
Filters
Front Panel
Purifying
filters
Air filters
Catechin
Triple Deodorizing Filter
every 2 weeks
every 6 months
If remote control
malfunctions / is misplaced
Save cost
Automatic Operation
HELPFUL INFORMATION
see page 34
see page 36
Built-in surge protection, BUT UNPLUG in case of 
very strong lightning!
When power resume
Use...
Close
Vacuum
Better performance!
Restored
Deleted –> set again! 
Random restart automatically
Remove
every 6 months
Damaged –> replace!
Vacuum refresh
Expose to direct sunlight
 
Thunder / Lightning
Power Failure
Reinstall
Reinstall
CWD 001049
Soaps Neutral 
household
detergents
Remove
Remove
hrs
IONIZER
38
CS-A18CKE CU-A18CKE / CS-A24CKE CU-A24CKE
PREPARATIONS
refer page 42
Indoor Unit
Pre-season
inspection
Insert batteries
Set Clock
Installation: see enclosed installation
instruction!
Use
Year
Confirm
Press
Insert batteries / close
OPEN front panel
Plug in
CLOSE front Panel
Place AIR filters
Place PURIFYING
filters
Remove AIR filters
Open / remove
Set time
Set current time
immediately
check
Rechargeable
check
Fans obstructed?
START cooling/heating
START
dry internal parts
OFF
Remove batteries
Unplug
Check performance
Call Service
Batteries
Same type!
For extended
non-operation
Recommended
Inspections
Consult an authorized distributor for inspection!
After several seasons and due to operational
conditions, performance may be reduced by dust or
there may be unpleasant smells.
Press button
Plug/breaker
14
HEAT
39
CS-A18CKE CU-A18CKE / CS-A24CKE CU-A24CKE
TROUBLESHOOTING
No problem
Operation delayed for 3 minutes after
successful restart
Self protection procedure
It sounds like water flowing...
Caused by refrigerant flow inside
Mist seems to emerge from the
indoor unit
Condensation effect due to cooling
Abnormal noise during operation
CALL authorized distributor
TURN OFF/UNPLUG
Power plug / cord become unnaturally warm
Circuit breaker switches off frequently
Switches / buttons do not operate properly
Water leak from Indoor Unit
Water / foreign particles have entered the Remote
Control
In case of...
No Operation
Remote control / display doesn’t work
Cooling/heating efficiency low
Noise too loud
Circuit breaker tripped?
Batteries empty?
Temperature set correctly?
Outdoor unit obstructed?
Installation work slanted?
Power plug OK?
TIMER used correctly?
Batteries correctly inserted? See page 39
Windows / doors closed?
Filters cleaned / replaced?
Intake / outlet ventilators obstructed?
Front grille / panel closed properly?
flashes, no warm air discharge
Defrosting at outdoor unit, max. 
12 min.
Outdoor unit emits water / steam
Condensed moisture due to cooling
40
CS-A18CKE CU-A18CKE / CS-A24CKE CU-A24CKE
Page of 89
Display