SAFETY PRECAUTIONS
EMERGENCY!
Immediately isolate from the mains supply (e.g. if there is a
smell of burning) 
Use only for...
Cooling
NEVER use this unit for purposes other than
those listed in these 
Operating Instructions. In particular, do not use
it for the preservation of food.
Installation
NEVER install, remove or
reinstall yourself
NOT in potentially explosive
atmosphere
Engage dealer /
specialist
Connect drain hose
properly
NEVER shared
Used connectors / breakers
easy reachable!
Engage dealer / specialist for mains connection including...
Plug in properly
Connect protective earth!
Mains connection
Before operating, read the safety
precautions thoroughly
Do NOT operate with wet hands
Do NOT stay long in the stream of cold air
NEVER use the plug to switch on/off
Ventilate the room periodically
Do NOT pull out the plug by the cable
Place nothing on the unit --> covered openings may cause
overheating
Do NOT insert finger or other objects into the unit! --> especially
dangerous for children!
Unused for a long time? --> OFF / unplug
If the supply cord is damaged or needed to be replaced, it must be
replaced by the manufacturer or its service agent or a similarly
qualified person in order to avoid a hazard. 
NEVER modify / damage mains cables / connectors
Operation
Dehumidifying
Heating
41
CS-A18CKE CU-A18CKE / CS-A24CKE CU-A24CKE
SAFETY PRECAUTIONS & FEATURES
Defect / suspicion of defect? —> Attend defects before use!
Do NOT repair yourself
Engage dealer / specialist
Defects
OFF and unplug (connector or breaker)
Do NOT wash!
Cleaning
Uninstalling and disposal of the unit ONLY by dealer /
specialist
Packaging recyclable
Waste disposal
refer page
Luminous button: convenient in the dark!
Automatic Operation: indoor temp. is gauged to select the
optimum mode
Ionizer Mode: produce negative ion for fresh air
Quiet Mode: to provide quiet operation
Powerful Mode: reaches the desired room temperature quickly
Auto Restart Control: after power failure, restart
automatically when power resume
Removable Front Panel: for quick and easy cleaning,
washable
Catechin Filter: Trapping dust, tobacco,  smoke / tiny particles, it inhibits
the growth of bacteria / viruses
Triple Deodorizing Filter: absorb odours produced by wall paper,
construction material and living environment
35
36
37
37
37
38
38
38 / 39
38 / 39
Indoor Unit
Outdoor Unit
Temperature
Wet Bulb
Dry Bulb
Operational
Condition
42
CS-A18CKE CU-A18CKE / CS-A24CKE CU-A24CKE
10 Installation Instructions
Required tools for Installation Works
1.
Philips screw driver
5.
Spanner
9.
Gas leak detector
13. Multimeter
2.
Level gauge
6.
Pipe cutter
10. Measuring tape
14. Torque wrench
18 N.m (1.8 kgf.m)
55 N.m (5.5 kgf.m)
65 N.m (6.5 kgf.m)
3.
Electric drill, hole core drill
(ø70 mm)
7.
Reamer
11. Thermometer
15. Vacuum pump
4.
Hexagonal wrench (4 mm)
8.
Knife
12. Megameter
16. Gauge manifold
10.1. Safety Precautions
     • 
• 
• 
• Read the following “SAFETY PRECAUTIONS” carefully before installation.
     • 
• 
• 
• Electrical work must be installed by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit
for the model to be installed.
     • 
• 
• 
• The caution items stated here must be followed because these important contents are related to safety. The meaning of each
indication used is as below. Incorrect installation due to ignoring of the instruction will cause harm or damage, and the
seriousness is classified by the following indications.
This indication shows the possibility of causing death or serious injury.
This indication shows the possibility of causing injury or damage to properties only.
The items to be followed are classified by the symbols:
Symbol with background white denotes item that is PROHIBITED from doing.
     • 
• 
• 
• Carry out test running to confirm that no abnormality occurs after the installation. Then, explain to user the operation, care and
maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference.
1.
Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, electrical shock or fire.
2.
Install according to this installation instruction strictly. If installation is defective, it will cause water leakage, electrical shock or fire.
3.
Use the attached accessories parts and specified parts for installation. Otherwise, it will cause the set to fall, water leakage, fire or
electrical shock.
4.
Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or installation is not properly
done, the set will drop and cause injury.
5.
For electrical work, follow the local national wiring standard, regulation and this installation instruction. An independent circuit and single
outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire.
6.
Use the specified cable (2.5 mm
2
) and connect tightly for indoor/outdoor connection. Connect tightly and clamp the cable so that no
external force will be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection.
7.
Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will
cause heat-up at connection point of terminal, fire or electrical shock.
8.
When carrying out piping connection, take care not to let air substances other than the specified refrigerant go into refrigeration cycle.
Otherwise, it will cause lower capacity, abnormal high pressure in the refrigeration cycle, explosion and injury.
9.
Do not damage or use unspecified power supply cord. Otherwise, it will cause fire or electrical shock.
10. Do not modify the length of the power supply cord or use of the extension cord, and do not share the single outlet with
other electrical appliances. Otherwise, it will cause fire or electrical shock.
43
CS-A18CKE CU-A18CKE / CS-A24CKE CU-A24CKE
1.
The equipment must be earthed. It may cause electrical shock if grounding is not perfect.
2.
Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at
surrounding of the unit, it may cause fire.
3.
Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the
furniture.
ATTENTION
1. Selection of the installation location.
Select a installation location which is rigid and strong enough to support or hold the unit, and select a location for easy maintenance.
2.
Power supply connection to the room air conditioner.
Connect the power supply cord of the room air conditioner to the mains using one of the following method.
Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency.
In some countries, permanent connection of this room air conditioner to the power supply is prohibited.
 1. 
Power supply connection to the receptacle using a power plug.
Use an approved 16A power plug with earth pin for 2.0HP (C18CK, A18CK, RS-C18CK) and 20A for 2.5HP (C24CK, A24CK, RS-
C24CK) for the connection to the receptacle.
 2. 
Power supply connection to a circuit breaker for the permanent connection. Use an approved 16A circuit breaker 2.0HP (C18CK,
A18CK, RS-C18CK) and 20A for 2.5HP (C24CK, A24CK, RS-C24CK) for the permanent connection. It must be a double pole switch
with a minimum 3 mm contact gap.
3.
Do not release refrigerant.
Do not release refrigerant during piping work for installation, reinstallation and during repairing a refrigeration parts. Take care of the
liquid refrigerant, it may cause frostbite.
4.
Installation work.
It may need two people to carry out the installation work.
5.
Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.
44
CS-A18CKE CU-A18CKE / CS-A24CKE CU-A24CKE
Page of 89