a) Normal Deicing Time Diagram
(b) Overload Deicing Time Diagram
25
CS-A18CKE CU-A18CKE / CS-A24CKE CU-A24CKE
Quiet Operation Control
(For Heating Mode)
     • 
• 
• 
• Purpose of this operation is to provide quite heating operation compare to normal operation.
     • 
• 
• 
• When the Quiet Mode is set at the remote control, Quiet Mode LED illuminates, the sound level will be automatically
decreased 3 dB, against the present sound level operation.
     • 
• 
• 
• Quiet setting of fan speed rpm refer to Indoor Fan Speed Control.
     • 
• 
• 
• Manual Fan Speed:-
     − 
− 
− 
− Rpm control during Lo, Me & Hi Cool
     • 
• 
• 
• Auto Fan Speed:-
     − 
− 
− 
− Rpm control depends on the piping air temperature sensor of Indoor heat exchanger
     • 
• 
• 
• Quiet Mode Operation will stop if:-
     − 
− 
− 
− Quiet mode button is pressed again.
     − 
− 
− 
− Stopped by ON/OFF switch.
     − 
− 
− 
− Timer OFF activates.
     − 
− 
− 
− Powerful mode button is pressed.
26
CS-A18CKE CU-A18CKE / CS-A24CKE CU-A24CKE
8.5. Automatic Mode Operation
 1. When the Automatic Mode Operation is selected, the indoor fan operates at SLo fan speed for 25 seconds to sense intake air
temperature and determine the 1st operation mode. If indoor intake air temperature is less than 16°C, Heating mode will
immediate operate.
 2. Operation mode will be determine again after 1 hour of operation, if the room temperature reaches to set temperature and
compressor off time is over 7 minutes 30 seconds continuously.
The present operation mode will be continued, if the room temperature does not reach to set temperature (Compressor keeps running)
eventhough after 1 hour from automatic operation mode started.
Present
Judgement
Next Mode
Mode
Cooling
Soft Dry
Heating
O
O
Cooling
23°C
Cooling
(Judgement:
Not Applicable
(Judgement:
Heating
23°C & Above)
Below 23°C)
O
O
Soft Dry
20°C
Soft Dry
Not Applicable
(Judgement:
(Judgement:
Heating
20°C & Above)
Below 20°C)
O
O
Heating
Cooling
(Judgement:
Not Applicable
(Judgement:
25°C
Heating
Above 25°C)
25°C & below)
Automatic Set Temperature
Refer 3. as below.
 3. Automatic Set Temperature
For each operation, set temperature will automatically set as shown below.
However it can be selected 2°C higher or 2°C lower from standard set temperature by pressing the “Room Temperature Setting
button”.
Operation
Hi
(Standard)
Lo
(+2°C)
(±0°C)
(-2°C)
Cooling
27°C
25°C
23°C
Soft Dry
24°C
22°C
20°C
Heating
23°C
21°C
19°C
     • 
• 
• 
• The mode judging temperature and standard setting temperature can be increased by 2°C, by open the circuit of JX1 at
indoor electronic controller.
27
CS-A18CKE CU-A18CKE / CS-A24CKE CU-A24CKE
Vertical Airflow Direction Auto-Control
     • 
• 
• 
• When set a Airflow Direction Auto-Control with remote
control, the louver swings up and down as shown in the
diagram.
     • 
• 
• 
• The louver does not swing when the Indoor Fan Motor
stops during operation at the upper limit.
     • 
• 
• 
• When stopped with remote control, the discharge vent is
reset, and stopped at the closing position.
     • 
• 
• 
• During Anti-dew condensation prevention, Airflow Direction
Auto-control angle change from 0° - 36° to 12° - 28° under
Cooling and Soft Dry operation mode.
Vertical Airflow Direction manual Control
     • 
• 
• 
• When the manual Airflow Direction Selection Button is
pressed, the automatic airflow is released and the airflow
direction louver move up and down in the range shown in
the diagram.
The louver can be adjusted by pressing the button to the
desired louver position.
     • 
• 
• 
• When the remote control is used to stop the operation, the
discharge vent is reset, and stopped at the closing position.
     • 
• 
• 
• During Anti-dew condensation prevention, Airflow Direction
Manual control angle change from 14°, 19°, 24°, 30°, 36° to
16°, 18°, 20°, 22°, 24° under Cooling and Soft Dry operation
mode.
8.6. Random Auto Restart Control
     • 
• 
• 
• If there is a power failure during air conditioner operation, operation will be automatically restarted after 3 to 4 minutes when the
power is resumed.
It will start with previous operation mode and airflow direction.
     • 
• 
• 
• Restart time is decided randomly using 4 parameter:-
Intake air temperature, setting temperature, fan speed and Air Swing Blade position.
     • 
• 
• 
• Auto Restart Control is not available when Timer is set.
     • 
• 
• 
• This control can be omitted by open the circuit of JX2. (Refer Circuit Diagram)
8.7. Airflow Direction Control
1. There is no swinging while indoor fan motor is stopped during Cooling, Ion and Soft Dry operation.
2. In Heating operation, when the piping air temperature reaches 38°C, the louver is changed from upper to lower limit position. When the
piping air temperature falls to 35°C, the louver is changed from lower to upper limit position.
28