LG F1232RDSW Service Manual ▷ View online
21
NO WATER SUPPLY
Is water supply shut-off?
Open the tap.
Check the AIR CHAMBER
and the tube clogged
with impurity.
and the tube clogged
with impurity.
Replace the INLET VALVE
ASSEMBLY.
ASSEMBLY.
Replace the MAIN PWB
ASSEMBLY
ASSEMBLY
Clean the filter.
Is the tap opened?
NO
NO
YES
Is the inlet valve filter clogged with impurity?
YES
NO
When you press both Rinse button and Spin button
simultaneously, is the water level frequency below
240?
simultaneously, is the water level frequency below
240?
YES
YES
Is resistance between each terminal of INLET
VALVE ASSEMBLY is 2~8 kΩ?
VALVE ASSEMBLY is 2~8 kΩ?
NO
Check the voltage of the inlet valve connector
AC 220-240V~.
(Refer to 7-2 QC TEST MODE)
AC 220-240V~.
(Refer to 7-2 QC TEST MODE)
NO
DETERGENT DOES NOT FLOW IN
Refer to
NO WATER SUPPLY
Check the wiring on the
dispenser.
dispenser.
Clean the drawer.
Put the detergent in the
correct position
PRE+MAIN
MAIN WASH
: Detergent
Is water supplied?
NO
YES
Is detergent put in the correct compartment of
the drawer?
the drawer?
NO
YES
Are receptacle correctly connected to the
terminals of the INLET VALVE ASSEMBLY?
terminals of the INLET VALVE ASSEMBLY?
NO
YES
YES
NO
Is the detergent hardened?
22
S O F T E N E R D O E S N O T F L O W I N
Refer to
NO WATER SUPPLY
Check the wiring on the
dispenser.
dispenser.
Clean the cap and
drawer.
drawer.
Put it in the correct
compartment.
compartment.
Is water supplied?
NO
YES
Are receptacles correctly connected to the terminals
of the INLET VALVE ASSEMBLY?
of the INLET VALVE ASSEMBLY?
Is softener put in the correct compartment of the
drawer?
drawer?
NO
YES
YES
NO
Is the softener cap clogged?
A B N O R M A L S O U N D
Fix the bolt tightly.
Replace the STATOR
ASSEMBLY or ROTOR
ASSEMBLY.
ASSEMBLY or ROTOR
ASSEMBLY.
Is the motor bolt loosened?
YES
NO
YES
Is there friction noise from the motor?
YES
23
HEATING WITHOUT WATER
Spin
Rinse
Replace the
S.PRESSURE SWITCH
ASSEMBLY
S.PRESSURE SWITCH
ASSEMBLY
Replace the MAIN PWB
ASSEMBLY
ASSEMBLY
When pressing Rinse and Spin. at the same time
after draining, is the water level frequency 255?
When pressing Rinse and Spin. buttons at the
same time while washing, is the water level
frequency between 230 - 243 ?
after draining, is the water level frequency 255?
When pressing Rinse and Spin. buttons at the
same time while washing, is the water level
frequency between 230 - 243 ?
AC 220-240V
After completely drained and turn
off water, the washing machine is
operated under the [Sanitary] condition.
Check the voatage between two pins is the
Voltage 0 V AC?
off water, the washing machine is
operated under the [Sanitary] condition.
Check the voatage between two pins is the
Voltage 0 V AC?
YES
DRAIN MALFUNCTIONING
(1)
(2)
Repair the DRAIN HOSE
ASSEMBLY.
ASSEMBLY.
Remove foreign material.
Reconnect or repair the
connector
connector
Repair the DRAIN PUMP
ASSEMBLY.
ASSEMBLY.
Repair the MAIN PWB
ASSEMBLY.
ASSEMBLY.
Is the drain hose twisted or frozen?
YES
NO
Is the connector disconnected, disassembled?
YES
Is the coil of the drain pump cut-off?
(resistance of coil is 80~15
(resistance of coil is 80~15
0Ω
)
YES
NO
NO
Is the impeller of the drain pump clogged?
YES
NO
NO
When checking voltage between connectors
( , )on spinning, is the voltage 220-240V
as the figure?
( , )on spinning, is the voltage 220-240V
as the figure?
NO
YES
24
WASH HEATER TROUBLE
Replace the MAIN PWB
ASSEMBLY
ASSEMBLY
Normal
Replace the
HEATER ASSEMBLY
HEATER ASSEMBLY
AC 220-240V
After power off, is the resistance of wire
(YELLOW-BLACK) connectors between
10Ω ~ 30Ω?
(YELLOW-BLACK) connectors between
10Ω ~ 30Ω?
After power off and the heater terminal is
disconnected, is the resistance 10Ω ~ 30Ω?
disconnected, is the resistance 10Ω ~ 30Ω?
NO
HEATING CONTINUOUSLY ABOVE
THE SETTING WATER TEMPERATURE
Check if inlet hose is
connected to a hot
faucet ; otherwise, replace
PWB ASSEMBLY(Main)
connected to a hot
faucet ; otherwise, replace
PWB ASSEMBLY(Main)
Replace Thermister
Push the THERMISTOR
tightly to the rubber.
tightly to the rubber.
When pressing Water Temp. during, is the
displayed temperature is over 10
higher than the selected temp?
displayed temperature is over 10
higher than the selected temp?
NO
YES
Is the resistance between Thermistor
Comectors 2.5k
Comectors 2.5k
Ω ~ 180kΩ
?
NO
YES
YES
NO
NO
YES
YES
When checking THERMISTOR on the tub is the
THERMISTOR loosened above 2mm from
the rubber?
THERMISTOR loosened above 2mm from
the rubber?
When checking the voltage between
connector during whites washing. is the
voltage 220-240V~?
connector during whites washing. is the
voltage 220-240V~?
Click on the first or last page to see other F1232RDSW service manuals if exist.