DOWNLOAD LG LM-3060HL Service Manual ↓ Size: 1.42 MB | Pages: 72 in PDF or view online for FREE

Model
LM-3060HL
Pages
72
Size
1.42 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
lm-3060hl.zip
Date

LG LM-3060HL Service Manual ▷ View online

70
2. OUTDOOR UNIT
- 5 -
Product Specifications
LM-3060HL
A UNIT
B/C UNIT
1,220~240,50
14,500/15,000
11,500/13,500
22,500/21,500
20,000/20,500
27,500/25,500
2,400/2,750
2,350/2,850
2,700/2,500
2,650/2,550
2,850/2,400
12.3/13.0
12.0/16.5
13.0/12.5
12.6/12.5
13.5/12.3
6.04/5.46
4.89/4.74
8.33/8.6
7.55/8.04
9.65/10.63
Model Name
BTU/h
1-UNIT
2-UNIT
3-UNIT
A
B(C)
A+B(C)
B+C
A+B+C
Capacity
(Cooling/
Heating)
Input
(Coolig/
Heating)
Running
Current
(Cooling/
Heating)
EER
(Cooling/
Heating)
Air Circulation (Cooling/Heating)
Met Weight
Dimension
Noise Level
A-UNIT
B/C-
UNIT
Refrigerant
Airflow Direction Control (Up & Down)
Remocon Type
Sleeping Operation
Service Valve
W
A
BTU/h.W
m
3
/min
kg
mm
dB(A)
g
Power Source
ø, V, Hz
Unit
Item
1-UNIT
2-UNIT
3-UNIT
A
B(C)
A+B(C)
B+C
A+B+C
1-UNIT
2-UNIT
3-UNIT
A
B(C)
A+B(C)
B+C
A+B+C
1-UNIT
2-UNIT
3-UNIT
A
B(C)
A+B(C)
B+C
A+B+C
INDOOR
OUTDOOR
INDOOR
OUTDOOR
INDOOR
OUTDOOR
INDOOR
OUTDOOR
Liquid
1/4"(6.35)
Gas
1/2"(12.7)
Liquid
1/4"(6.35)
Gas
3/8"(9.52)
8.5/9.0
9.5/10.0
56/58
10
80
W
810 x 
H
302 x 
D
183
W
870 x 
H
800x 
D
320
36
38
58
2,150
O
O
L.C.D Wireless
O
O
(1) Indoor Unit
- 6 -
Dimensions
45
70
50
Tubing hole cover
Tubing hole cover
Installation plate
Hole for piping
LM-3060HL
W
mm
810
H
mm
302
D
mm
183
DIM
MODEL
W
D
H
- 7 -
W
L1
L2
D
H
L3
L4
L5
L6
L7
L8
L9
L10
L10
L10
L10
L10
(2) Outdoor Unit
Liquid side
3-way valve
Gas side
3-way valve
LM-3060HL
W
mm
870
H
mm
800
D
mm
320
L1
mm
370
L2
mm
25
L3
mm
775
L4
mm
25
L5
mm
546
L6
mm
160
L7
mm
160
L8
mm
64
L9
mm
76.5
L10
mm
50
DIM
MODEL
Page of 72
Display