- 44 -
1
Press the Start/Stop Button after pressing the
Remote Control RESET Button or changing
batteries for Remote Control.
2
Press the Time Setting Button.
3
Press the Time SET Button.
Note: Check a.m. and p.m. Indicator in setting time.
7. Setting the Present Time
The present time can be set only when pressing the reset button or changing batteries for Remote Control.
⁄B
Horizontal Airflow Direction Control
• Adjust the horizontal airflow direction by manually moving the horizontal airflow direction louver by hand.
Warnning:
Be sure the power switch of the outdoor unit is set to
"OFF".
To remove the Grille from the Chassis.
• Set the up-and-down air discharge louver to open
position (horizontally) by finger pressure.
• Open the screw caps upward and remove the
securing screws.
• To remove the Grille, pull the lower left and right
side of the grille toward you (Slightly titled) and lift it
straight upward.
1. To remove the sensor, housing connect, earth
conductor & step motor conductor with sensor
holder, Motor, Evaporator & P.C.B.
- 47 -
Disassembly of the parts (Indoor unit)
Push on the right and the left side.
Screw cap
(both the left and the right side)
Screw
(both the left and the right side)
2. To remove the Control Box.
• Remove 4 securing screws.
• Pull the control box out from the chassis
carefully.
3. To remove the Discharge Grille.
• Remove the securing screw.
• Pull the discharge grille out from the chassis
carefully.
4. To remove the Evaporator.
- 48 -
• Unhook the tab on the left inside edge of the
chassis by pressing it outwards and at the same
time, slightly pull the evaporator until the tab is
clear of the end-plate.
• Remove the evaporator from the chassis
carefully.
• Unhook the tab on the right inside of the chassis
at the same time, slightly pull the evaporator
toward you until the tab is clear of the slot.
5. To remove the Cross-Flow Fan.
• Pull the left end of the cross-flow fan with the
self-aligning bearing out the groove.
• Remove the cross-flow fan by sliding it out from
the shaft of fan motor.
6. To remove the Fan Motor.
• Pick it up from the groove. (Do not remove a
black rubber as a spacer).
- 49 -
Tab
Pull
Evaporator
End Plate
evaporator
Tab
Evaporator
Cross-flow
fan
Bearing
Cross-flow
fan
Fan
motor
Pull