Report No.: 1009940
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
A
Annex A, Additional requirements for apparatus with protection against
splashing water
splashing water
A.5
Marking and instructions
N/A
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
N/A
A.10 Insulation
requirements
N/A
A.10.2
Splash and humidity treatment
N/A
A.10.2.1
Enclosure provides protection against splashing
water
water
N/A
A.10.2.2
Humidity treatment carried out for 7 days
N/A
B
Annex B, Apparatus to be connected to the TELECOMMUNICATION NETWORKS
Complies with IEC 62151 clause 1
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
N/A
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
standard
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
Page 23 of 54
Report No.: 1009940
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
L
ANNEX L, Additional requirements for electronic flash apparatus for
photographic purposes
photographic purposes
L. 5
Marking and instructions
L. 5.4
Instructions for battery chargers and Supply
apparatus indicating type or model number of flash
apparatus with which it is to be used
apparatus indicating type or model number of flash
apparatus with which it is to be used
N/A
Instructions for flash apparatus indicating type or
model number of battery chargers or Supply
apparatus with which it is to be used
model number of battery chargers or Supply
apparatus with which it is to be used
N/A
L. 7
Heating under normal operating conditions
L7.1.5 &
L11.2.6
Lithium batteries meet permissible temp rise in Table
3 , unless comply with 6.2.2.1.or 6.2.2.2 of
IEC 60086-4
3 , unless comply with 6.2.2.1.or 6.2.2.2 of
IEC 60086-4
N/A
L. 9
Electric shock hazard under normal operating conditions
L. 9.1.1
Terminals to connection to synchroniser not
HAZARDOUS LIVE
HAZARDOUS LIVE
N/A
L.10 Insulation
requirements
N/A
L. 10.3.2
High frequency puls ignition
N/A
L. 12
Mechanical strength
L. 12.1.3
Windows for flash tubes are excluded from steel ball
impact test
impact test
N/A
L. 14
Components
L14.6.6
Mains switch characteristics appropriate to its
function under normal conditions
function under normal conditions
N/A
L. 20
Resistance to fire
L. 20.1 c)
Trigger coil for discharge purpose is not considered
to be a POTENTIAL IGNITION SOURCE
to be a POTENTIAL IGNITION SOURCE
N/A
Page 24 of 54
Report No.: 1009940
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by position of
the functional switch (W)……………………… ……..:
the functional switch (W)……………………… ……..:
--
—
Operating conditions
Un (V)
In (A)
Pn (W)
Pout (W)
253 0.4 72 31
Loudspeaker impedance (Ω) ..................................: 3.4 (measured)
--
Several loudspeaker systems
--
Marking of loudspeaker terminals
(High Level out/in)
--
Temperature Rise dT of Part
dT (K)
Limit max dT (K)
Test Condition No.
253V
--
--
Iron core, mains transformer
43
—
Supply wiring insulation (not under
mechanical stress)
mechanical stress)
20
60 (50)
PCB 26
85 (75)
Heat sink, on rear panel
24
40 (30)
Rear panel, above heat sink
25
40 (30)
Top of cabinet
8
60 (50)
TR1 windings (Measured with
thermocouple)
thermocouple)
24
85 (75)*
PCB – Stand-by PSU
22
85 (75)*
Ambient temperature t1 (
o
C) .............................
20 —
—
Ambient temperature t2 (
o
C) .............................
21 —
—
Temperature rise dT of winding:
dT = (R
dT = (R
2
– R
1
) x (234.5 + t1) – (t2 – t1)
R
1
R
1
(Ω)
R
2
(Ω)
dT (K)
Limit max
(K)
Insulation class
Transformer
Primary winding
8.885
10.565
47
85 (75)
E
Secondary winding (yellow)
0.5635
0.6646
45
85 (75)
E
Secondary winding (red)
1.0953
1.296
46
85 (75)
E
Note: Temperature limits in parenthesis are for tropical climates (Singapore).
Page 25 of 54
Report No.: 1009940
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
7.2
TABLE: softening temperature of thermoplastics
N/A
Temperature T of part
T - normal con-
ditions (
o
C)
T - fault condi-
tions (
o
C)
Min T softening
(
o
C)
10.3
TABLE: insulation resistance measurements
P
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (mains fuse disconnected)
>10
Min. 2
Between parts separated by basic or supplementary insulation
>10
Min. 2
Between parts separated by double or reinforced insulation
>10
Min. 4
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (mains fuse disconnected)
2120 peak
No
Between parts separated by basic or supplementary insulation
2120 peak
No
Between parts separated by double or reinforced insulation
4240 peak
No
11.2
TABLE: summary of fault condition tests
P
Voltage (V) 0.9 or 1.1 times rated voltage .............: 220-230
—
Ambient temperature (
o
C) .......................................: 50-60
—
Monitored point:
Under fault conditions specified below...see table in next page
dT (K)
Permitted
dT (K)