JBL SUB 140 (serv.man2) EMC - CB Certificate ▷ View online

 
Page 6 of 54 
Report No.: 1009940 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
 
d) Class I earth connection warning  
 
N/A 
 
e) Instructions for multimedia system connection  
 
N/A 
 
f) Special stability warning for attachment of the 
apparatus to the floor/wall  
 N/A 
 
g) Warning: battery exposure to heat  
 
N/A 
 
h) Warning: protective film on CRT face  
 
N/A 
5.4.2 
a-b) Disconnect device: plug/coupler or all-pole 
mains switch location, accessibility and markings  
 P 
 
c) Instructions for permanently connected equipment   
N/A 
 
Marking, signal lamps or similar for completely 
disconnection from the mains  
 N/A 
 
6 Hazardous 
radiation 
 
6.1 
Ionizing radiation < 36pA/kg (0.5mR/h)  
 
N/A 
 
Ionizing radiation under fault condition  
 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1 …….:  
N/A 
 
Emission limits under fault conditions …………..: 
 
N/A 
 
Heating under normal operating conditions 
 
7.1 
Temperature rises not exceeding specified values; 
fuse links and other protective devices defeated  
(see appended table) 
7.1.1 
Temperature rise of accessible parts  
(see appended table) 
7.1.2 
Temperature rise of parts providing electrical 
insulation  
(see appended table) 
7.1.3 
Temperature rise of parts acting as a support or as a 
mechanical barrier  
(see appended table) 
7.1.4 
Temperature rise of windings  
(see appended table) 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table) 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0.2A at least 150
 o
C  
(see appended table) 
 
 
Page 7 of 54 
Report No.: 1009940 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
 
Constructional requirements with regard to the protection against electric shock
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare  
 P 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc.  
 N/A 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material  
 P 
8.4 
No risk of electric shock from accessible parts or 
from parts rendered accessible following the removal 
of a cover which can be removed by hand  
 P 
8.5 
Class I equipment  
 
Basic insulation between hazardous live parts and 
earthed accessible parts  
 N/A 
 
Resistors bridging basic insulation complying with 
14.1 a)  
 N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1 a)  
 N/A 
 
Protective earthing terminal  
 
N/A 
8.6 
Class II equipment and Class II constructions within Class I equipment  
 
Double or reinforced insulation between hazardous 
live parts and accessible parts  
 P 
 
Components bridging double or reinforced insulation 
complying with 14.1 a) or 14.3  
 P 
 
Basic insulation bridged by components complying 
with 14.3.4.3.  
 N/A 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.2.1 a)  
 N/A 
 
Double or reinforced insulation being bridged with 2 
capacitors in series complying with 14.2.1 a)  
 N/A 
 
Double or reinforced insulation being bridged with a 
single capacitor complying with 14.2.1 b)  
C03 P 
8.7 
This clause is void  
 
 
8.8 
Basic or supplementary insulation > 0.4mm (mm) ...:   
 
Reinforced insulation > 0.4mm (mm) ……………….:   
 
Thin sheet insulation (excluding non-separable thin 
sheet insulation. See 8.22)  
 N/A 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3  
 N/A 
 
Page 8 of 54 
Report No.: 1009940 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3  
 N/A 
 
Reinforced insulation, two layers each of which meet 
10.3  
 N/A 
 
Reinforced insulation, three layers any two which 
meet 10.3  
 N/A 
8.9 
Adequate insulation between internal hazardous live 
conductors and accessible parts  
 P 
 
Adequate insulation between internal hazardous live 
parts and conductors connected to accessible parts  
 P 
Double insulation between conductors connected to 
the mains and accessible parts.  
 P 
8.10 
Double insulation between internal  hazardous live 
parts and conductors connected to accessible parts. 
 P 
8.11 
Detaching of wires  
 
No undue reduction of creepages or clearance 
distances if wires become detached  
No risk of any wire becoming 
detached. 
N/A 
 
Vibration test carried out …………………………: 
No, see above 
N/A 
8.12 
This clause is void  
 
 
8.13 
Adequate fastening of windows, lenses, lamp covers 
etc. (pull test 20N for 10s)  
 P 
8.14 
Adequate fastening of covers (push/pull test 50N for 
10 s)  
 P 
8.15 
No risk of damage to the insulation of internal wiring 
due to hot parts or sharp edges  
 P 
8.16 
Only special supply equipment can be used  
 
N/A 
8.17 
Insulated winding wire without additional interleaved 
insulation  
In stand-by transformer TR1 
8.18 
Endurance test as required by 8.17  
 
N/A 
8.19 
Disconnection from the mains 
8.19.1 
Disconnect device  
Mains plug 
 
All-pole switch or circuit breaker with >3mm contact 
separation  
 N/A 
8.19.2 
Mains switch ON indication  
 
N/A 
8.20 
Switch not fitted in the mains cord  
 
8.21 
Bridging components comply with clause 14  
C15 
8.22 
Non-separable thin sheet material  
 
N/A 
 
 
Page 9 of 54 
Report No.: 1009940 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
Electric shock hazard under normal operating conditions 
 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000V ac or >1500V dc complies 
with clause 13.3.1 for basic insulation  
 N/A 
9.1.1.1 
a) Open circuit voltages  
 
 
b) Touch current measured from terminal devices 
using the network in annex D …………………: 
Voltage U1: 0.19V peak 
Voltage U2: 0.02V peak 
 
c) Discharge not exceeding 45μC  
 
N/A 
 
d) Energy of discharge not exceeding 350mJ  
 
N/A 
9.1.1.2 
Test with test finger and test probe  
 
9.1.2 
No hazardous live shafts of knobs, handles or levers   
9.1.3 
Ventilation holes and other holes tested by means of 
4mm x 100mm test pin  
No ventilation holes 
N/A 
9.1.4 
Terminal devices tested with 1mm x 20mm test pin 
(10 N); test probe D of IEC 61032  
 P 
 
Terminal devices tested with 1mm x 100mm straight 
wire (1N); test probe D of IEC 61032  
 P 
9.1.5 
Pre-set controls tested with 2.5 mm x 100mm test 
pin (10N); test probe C of IEC 61032  
 N/A 
9.1.6 
No shock hazard due to stored charge on withdrawal 
of the mains plug; voltage (V) after 2s ……………: 
 P 
 
If C is not greater than 0.1μF no test needed  
 
N/A 
9.1.7 
Resistance to external forces 
 
a) Test probe 11 of IEC 61032 for 10s (50N)  
 
 
b) Test hook of fig. 4 for 10s (20N)  
 
 
c) 30mm diameter test tool for 5s (100 or 250N)  
 
9.2 
No hazard after removing a cover by hand  
 
N/A 
 
10 Insulation 
requirements 
 
10.1 
Insulation resistance (MΩ) at least 2MΩ min. after 
surge test for basic and 4MΩ min. for reinforced 
insulation …………………………………………..: 
 N/A 
10.2 
Humidity treatment 48h or 120h …………………….:  Both 48 and 120h 
10.3 
Insulation resistance and dielectric strength between 
mains terminals  
 P 
 
Insulation Resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class 1)  
 N/A 
 
Insulation resistance and dielectric strength across 
REINFORCED insulation (Class II)  
 P 
Page of 73