DOWNLOAD JBL SUB 140 (serv.man2) Service Manual ↓ Size: 6.45 MB | Pages: 73 in PDF or view online for FREE

Model
SUB 140 (serv.man2)
Pages
73
Size
6.45 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
sub-140-sm2.pdf
Date

JBL SUB 140 (serv.man2) EMC - CB Certificate ▷ View online

 
Page 3 of  54 
Report No.: 1009940 
 
TRF No. IEC60065J 
 
Summary of testing: 
Tests performed (name of test and test clause): 
See Test Report 
Testing location: 
See page 2 
Summary of compliance with National Differences: Group- and national differences for the CENELEC 
countries have been checked. The national differences for Singapore and Korea have also been checked. 
Copy of marking plate 
 
 
 
 
 
Page 4 of  54 
Report No.: 1009940 
 
TRF No. IEC60065J 
 
Test item particulars: 
 
Classification of installation and use............................ : Class II 
Supply connection ....................................................... : Mains plug 
...................................................................................... :  
...................................................................................... :  
Possible test case verdicts: 
 
- test case does not apply to the test object .................: N/A (Not Applicable) 
- test object does meet the requirement.......................: P (Pass) 
- test object does not meet the requirement.................: F (Fail) 
Testing.: 
 
Date of receipt of test items ..........................................: -- 
Date(s) of performance of tests ....................................: -- 
General remarks: 
The test results presented in this report relate only to the object tested. 
This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. 
"(see Enclosure #)" refers to additional information appended to the report. 
"(see appended table)" refers to a table appended to the report. 
 
Throughout this report, a point is used as the decimal separator. 
List of test equipment must be kept on file and available for review. 
 
General product information: 
This Test Report is based on Test Report 704079 and 711306 with CB Ref. Nos. SE-50277 and SE-50277M1. 
This new Test Report is compiled due to a modification to pass the ErP requirements and also because an 
updating of the EN-standard to EN 60065:2002 + A1:2006 + A11:2008. 
Some parts of this Test Report is also based on Test Report 913893, CB Ref. No. SE-58634M1.  
However, no test sample was considered necessary for this updating. 
 
Factory:  
Dongguan Meiloon Acoustic Equipment Co., Ltd. 
No. 77. Yuanlin Road, Feng Huang Industrial Estate 
Tangxia, Dongguan, Guangdong Province, 523727, CHINA 
 
Page 5 of 54 
Report No.: 1009940 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
3 General 
requirements 
 
 
Safety class of the apparatus …………………: 
Class II 
 
General test conditions 
 
4.1.4 
Ventilation instructions require the use of the test box  No 
 
Marking and instructions 
 
 
Comprehensible and easily discernible 
 
 
Permanent durability against water and petroleum 
spirit  
 P 
5.1 
a) Identification, maker ………………………………..:
  
 
b) Model number or type reference ……………..: 
SUB140/230 P 
 
c) Class II symbol if applicable …………………..: 
 
 
d) Nature of supply …………………………….....: 
 
e) Rated supply voltage …....…………….………: 
220-230V 
 
f) Mains frequency if safety dependant ……......…….: 50-60Hz 
g) Rated current or power consumption for 
apparatus supplied by supply apparatus for general 
use ………: 
 N/A 
Measured current or power consumption …………...:  
N/A 
 
Deviation %  (max 10%) ………………………....: 
 
N/A 
 
h) Power consumption marking for apparatus other 
than single phase ……………………………..……….:
 
 
N/A 
i) Rated current or power consumption for apparatus 
intended for connection to an a.c. mains supply ……:
 
200W 
Measured current or power consumption …..…….....: 220V: 65W, 230V: 69W 
 
Deviation %  (max 10%) ………………………....: 
-- 
5.2 
Earth terminal  
 
N/A 
 
Hazardous live terminals  
 
N/A 
 
Supply output terminals (other than mains)  
 
N/A 
5.3 
Use of triangle with exclamation mark  
 
5.4 
Instructions for use  
 
5.4.1 
 
a) Mains powered equipment not exposed to 
dripping or splashing. Warning concerning objects 
filled with liquid, etc.  
 P 
 
b) Hazardous live terminals, instructions for wiring   
 
N/A 
 
c) Instructions for replacing lithium battery  
 
N/A 
Page of 73
Display