JBL SUB 140 (serv.man2) EMC - CB Certificate ▷ View online
Page 10 of 54
Report No.: 1009940
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
11 Fault
conditions
11.1
No shock hazard under fault condition
P
11.2
Heating under fault condition
P
Flames extinguish within 10 seconds
P
No hazard from softening solder
P
Soldered terminations not used as protective
mechanism
mechanism
P
11.2.1
Measurement of temperature rises
(see appended table)
P
11.2.2
Temperature rise of accessible parts
(see appended table)
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
(see appended table)
P
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100K for max.
5min
exceeding the limits of table 3 by max. 100K for max.
5min
N/A
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not more
than 100K for an area not greater than 2cm² …:
to 20.1.3, exceeding the limits of table 3 by not more
than 100K for an area not greater than 2cm² …:
N/A
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300K for an area not greater than
2cm² for a maximum of 5 min
to 20.1.3 up to 300K for an area not greater than
2cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
At Uin=198V, voltage across
interruption <50Vp
At Uin=253V, no interruption,
mains fuse broke
interruption <50Vp
At Uin=253V, no interruption,
mains fuse broke
(see table 11)
P
Class I protective earthing maintained
N/A
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
P
11.2.5
Temperature rise of windings
(see appended table)
P
11.2.6
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.5
11.2.1 to 11.2.5
(see appended table)
P
Page 11 of 54
Report No.: 1009940
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
12 Mechanical
strength
12.1.1
Bump test where mass >7kg
P
12.1.2
Vibration test
No connection of part, which
might impair safety, can become
loose.
might impair safety, can become
loose.
P
12.1.3
Impact hammer test
P
Steel ball test
P
12.1.4
Drop test for portable apparatus where mass ≤ 7kg
N/A
12.1.5
Thermoplastic enclosures stress relief test
N/A
12.2
Fixing of knobs, push buttons, keys and levers
P
12.3
Remote controls with hazardous live parts
N/A
12.4
Drawers (pull test 50N, 10s)
N/A
12.5
Antenna coaxial sockets providing isolation
N/A
12.6
Telescoping or rod antennas construction
N/A
12.6.1
Telescoping or rod antennas securement
N/A
13
Clearances and creepage distances
13.1
Clearances in accordance with 13.3
P
Creepage distances in accordance with 13.4
P
13.2
Determination of operating voltage
P
13.3
Clearances
13.3.1 General
P
13.3.2
Circuits conductively connected to the mains comply
with table 8 and, where applicable, table 9 ……..:
with table 8 and, where applicable, table 9 ……..:
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
Circuits not conductively
connected to the mains cannot
cause any shock hazard
connected to the mains cannot
cause any shock hazard
P
13.3.4
Measurement of transient voltages
N/A
13.4
Creepage distances
Creepage distances greater than table 11 minimum
values
values
P
Page 12 of 54
Report No.: 1009940
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
13.5
Printed boards
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
IEC 60664-3 (basic insulation only)
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with 13.3
and 13.4
clearances and creepage distances comply with 13.3
and 13.4
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
Temperature cycle test and dielectric strength test
N/A
13.7
Enclosed, enveloped or hermetically sealed parts not
conductively connected to the mains, clearances and
creepage distances as in table 12
conductively connected to the mains, clearances and
creepage distances as in table 12
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
N/A
14 Components
14.1
Resistors
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N/A
Resistors separately approved ……………………….:
N/A
14.2
Capacitors and RC units
Capacitors separately approved ……………………:
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
Edition :
C03
P
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
Edition :
C06, C15, C19
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ……………:
connected to the mains: tests for X2 ……………:
N/A
14.2.5
Capacitors with volume exceeding 1750mm³, where
short-circuit current exceeds 0.2A compliance with
IEC 60384-1, 4.38 category B or better ………:
short-circuit current exceeds 0.2A compliance with
IEC 60384-1, 4.38 category B or better ………:
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or
better ……………………………………:
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or
better ……………………………………:
N/A
Page 13 of 54
Report No.: 1009940
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Shielded by a barrier acc. to 20.1.4/ table 21 or
metal ……………………………………………….:
metal ……………………………………………….:
N/A
14.3
Inductors and windings
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
P
14.3.1
Transformers and inductors marked with
manufacturer's name and type ……………………….:
manufacturer's name and type ……………………….:
TRANSTEC
TT0860901570-E
TR1: DW KB1157-11486
TT0860901570-E
TR1: DW KB1157-11486
P
Transformers and inductors separately approved ….: No
N/A
14.3.2 General
14.3.3, 14.3.4.1, 14.3.5.1
P
Insulation material complies with clause 20.1.4
P
14.3.3
Constructional requirements
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
P
14.3.3.2
Transformers meet the constructional requirements
P
14.3.4
Separation between windings
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation) ………………...:
between hazardous live parts and accessible parts
(double or reinforced insulation) ………………...:
P
Coil formers and partition walls > 0.4mm
P
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
N/A
14.3.4.3
Separating transformers with at least basic insulation
N/A
14.3.5
Insulation between HAZARDOUS LIVE parts and ACCESSIBLE parts
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
P
Coil formers and partition walls > 0.4mm
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
Click on the first or last page to see other SUB 140 (serv.man2) service manuals if exist.