JBL SUB 140 (serv.man2) EMC - CB Certificate ▷ View online
Page 38 of 54
Report No.: 1009940
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Annex ZA
Cont.
P
Page 39 of 54
Report No.: 1009940
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Annex ZA
Cont.
P
GROUP DIFFERENCES FOR AMENDMENT 1
COMMON MODIFICATIONS
5.1 i)
in EN 60065:2002
Replace the note by:
NOTE For RATED POWER CONSUMPTION measurements of TVs reference is made to
EN 62087. Measurements are done in the ON (play) operating mode.
Replace the note by:
NOTE For RATED POWER CONSUMPTION measurements of TVs reference is made to
EN 62087. Measurements are done in the ON (play) operating mode.
N/A
5.4.1
Add the following indent:
za) A warning that excessive sound pressure from earphones and headphones can cause
hearing loss.
za) A warning that excessive sound pressure from earphones and headphones can cause
hearing loss.
P
6.1
6.1
6.1
in EN 60065:2002
Replace the subclause by:
Replace the subclause by:
Ionizing radiation
Equipment that might produce ionizing radiation is checked by measuring the amount of
radiation.
The amount of radiation is determined by means of a radiation monitor of the ionizing
chamber type with an effective area of 1000 mm
Equipment that might produce ionizing radiation is checked by measuring the amount of
radiation.
The amount of radiation is determined by means of a radiation monitor of the ionizing
chamber type with an effective area of 1000 mm
²
or by measuring equipment of other types
giving equivalent results.
Measurements are made with the equipment on test operating at the most unfavourable
supply voltage (see 4.2) and with operator controls and service controls adjusted so as to
give maximum radiation whilst maintaining the equipment operative for normal use.
Internal preset controls not intended to be adjusted during the lifetime of the equipment are
not considered to be service controls.
At any point 100 mm from the surface of the operator access area, the dose-rate shall not
exceed 1 μSv/h (0.1 mR/h) (see Note). Account shall be taken of the background level.
NOTE These values appear in Directive 96/29/Euratom.
Measurements are made with the equipment on test operating at the most unfavourable
supply voltage (see 4.2) and with operator controls and service controls adjusted so as to
give maximum radiation whilst maintaining the equipment operative for normal use.
Internal preset controls not intended to be adjusted during the lifetime of the equipment are
not considered to be service controls.
At any point 100 mm from the surface of the operator access area, the dose-rate shall not
exceed 1 μSv/h (0.1 mR/h) (see Note). Account shall be taken of the background level.
NOTE These values appear in Directive 96/29/Euratom.
N/A
Page 40 of 54
Report No.: 1009940
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Bibl. in EN
60065:2002
60065:2002
Replace the paragraph related to prEN 50332-2 by:
EN 50332-2:2003, Sound system equipment: Headphones and earphones associated with
portable audio equipment - Maximum sound pressure level measurement methodology and
limit considerations - Part 2: Matching of sets with headphones if either or both are offered
separately EN 60065:2002/A1:2006 - 4 -
EN 50332-2:2003, Sound system equipment: Headphones and earphones associated with
portable audio equipment - Maximum sound pressure level measurement methodology and
limit considerations - Part 2: Matching of sets with headphones if either or both are offered
separately EN 60065:2002/A1:2006 - 4 -
N/A
Bibl. in IEC
60065:2001/
A1:2005
60065:2001/
A1:2005
Add the following notes for the standards indicated:
IEC 60598-2-9 NOTE Harmonized as EN 60598-2-9:1989 + A1:1994 (not modified).
IEC 60598-2-17 NOTE Harmonized as EN 60598-2-17:1989 + A2:1991 (not modified).
IEC 60598-2-9 NOTE Harmonized as EN 60598-2-9:1989 + A1:1994 (not modified).
IEC 60598-2-17 NOTE Harmonized as EN 60598-2-17:1989 + A2:1991 (not modified).
P
ZB
ANNEX ZB TO EN 60065, SPECIAL NATIONAL CONDITIONS (EN)
2.6.1
DK: The following is added:
Certain types of CLASS I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
Justification: Heavy Current Regulations, Section
107.
Certain types of CLASS I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
Justification: Heavy Current Regulations, Section
107.
N/A
13.3.1
NO: To the second paragraph the following is
added:
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will remain
230V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
added:
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will remain
230V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
N/A
Page 41 of 54
Report No.: 1009940
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
15.1.1
DK: To the first paragraph the following is added:
In Denmark, supply cords of single phase
appliances having a rated current not exceeding 13
A shall be provided with a plug according to the
Heavy Current Regulations Section 107-2-D1.
Appliances of CLASS I provided with socket-outlets
with earth contact or which are intended to be used
in locations where protection against indirect
contact is required according to the wiring rules
shall be provided with a plug in accordance with
the Heavy Current Regulations Section 107-2-D1
standard sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for provided power to
CLASS II apparatus with a rated current of 2.5 A
shall have the following dimensions:
In Denmark, supply cords of single phase
appliances having a rated current not exceeding 13
A shall be provided with a plug according to the
Heavy Current Regulations Section 107-2-D1.
Appliances of CLASS I provided with socket-outlets
with earth contact or which are intended to be used
in locations where protection against indirect
contact is required according to the wiring rules
shall be provided with a plug in accordance with
the Heavy Current Regulations Section 107-2-D1
standard sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for provided power to
CLASS II apparatus with a rated current of 2.5 A
shall have the following dimensions:
Dimensions in mm
Other dimensions shall be in compliance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DKA 1-3 for portable socket-
outlets. Shutters are not required.
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall be
in compliance with the Heavy Current Regulations,
Section 107-2-D1, Standard Sheet DK 1-3a, DK 1-
5a or DK 1-7a.
Justification:
Heavy Current Regulations, Section 107
Other dimensions shall be in compliance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DKA 1-3 for portable socket-
outlets. Shutters are not required.
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall be
in compliance with the Heavy Current Regulations,
Section 107-2-D1, Standard Sheet DK 1-3a, DK 1-
5a or DK 1-7a.
Justification:
Heavy Current Regulations, Section 107
P
15.1.1
IE: Apparatus which is fitted with a flexible cable or
cord shall be provided with a 13A plug in accordance
with Statutory Instrument 525:97, “13A Plugs and
Conversion Adapters for Domestic Use
Regulations:1997.
cord shall be provided with a 13A plug in accordance
with Statutory Instrument 525:97, “13A Plugs and
Conversion Adapters for Domestic Use
Regulations:1997.
Justification: SI 525: 1997
P