DOWNLOAD JBL SUB 140 (serv.man2) Service Manual ↓ Size: 6.45 MB | Pages: 73 in PDF or view online for FREE

Model
SUB 140 (serv.man2)
Pages
73
Size
6.45 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
sub-140-sm2.pdf
Date

JBL SUB 140 (serv.man2) EMC - CB Certificate ▷ View online

 
Page 50 of 54 
Report No.: 1009940 
IEC60065 - ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
Annex ZA 
Cont. 
 
 
 
 
 
 
Page 51 of 54 
Report No.: 1009940 
IEC60065 - ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
Annex ZA 
Cont. 
 
 
 
 
Page 52 of 54 
Report No.: 1009940 
IEC60065 - ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
Annex ZB 
 
Annex ZB 
(normative) 
Special national conditions 
Special national condition: National characteristic or practice that cannot be 
changed even over a long period, e.g. climatic conditions, electrical earthing 
conditions. 
For the countries in which the relevant special national conditions apply these 
provisions are normative, for other countries they are informative. 
Add the following special national conditions: 
 
5.4 
 
Finland, Norway and Sweden 
To the end of 5.4 the following is added: 
CLASS I apparatus which is intended for 
connection to the building installation wiring via a 
plug or an appliance coupler, or both and in addition 
is intended for connection to other apparatus or a 
network shall, if safety relies on connection to 
protective earth or if surge suppressors are 
connected between the network TERMINALS and 
ACCESSIBLE parts, have a marking stating that the 
apparatus must be connected to an MAINS socket-
outlet with protective earth. 
The marking text in the applicable countries shall be 
as follows: 
In Finland: “Laite on liitettävä 
suojamaadoituskoskettimilla varustettuun 
pistorasiaan” 
In Norway: “Apparatet må tilkoples jordet 
stikkontakt” 
In Sweden: "Apparaten skall anslutas till jordat 
uttag" 
 N/A 
 
 
Page 53 of 54 
Report No.: 1009940 
IEC60065 - ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
5.4.1 
Norway and Sweden  
To the end of 5.4.1 (after the compliance statement) 
the following is added:  
The screen of the cable distribution system is 
normally not earthed at the entrance of the building 
and there is normally no equipotential bonding 
system within the building. Therefore the protective 
earthing of the building installation need to be 
isolated from the screen of a cable distribution 
system.  
It is however accepted to provide the insulation 
external to the equipment by an adapter or an 
interconnection cable with galvanic isolator, which 
may be provided by e.g. a retailer.  
The user manual shall then have the following or 
similar information in Norwegian and Swedish 
language respectively, depending on in what 
country the equipment is intended to be used in:  
“Equipment connected to the protective earthing of 
the building installation through the mains 
connection or through other equipment with a 
connection to protective earthing – and to a cable 
distribution system using coaxial cable, may in 
some circumstances create a fire hazard. 
Connection to a cable distribution system has 
therefore to be provided through a device providing 
electrical isolation below a certain frequency range 
(galvanic isolator, see EN 60728-11)”  
NOTE In Norway, due to regulation for installations of cable 
distribution systems, and in Sweden, a galvanic isolator shall 
provide electrical insulation below 5 MHz. The insulation shall 
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz, 
for 1 min.  
Translation to Norwegian (the Swedish text will also 
be accepted in Norway):  
“Utstyr som er koplet til beskyttelsesjord via 
nettplugg og/eller via annet jordtilkoplet utstyr – og 
er tilkoplet et kabel-TV nett, kan forårsake 
brannfare. For å unngå dette skal det ved tilkopling 
av utstyret til kabel-TV nettet installeres en 
galvanisk isolator mellom utstyret og kabel-TV 
nettet.”  
Translation to Swedish:  
”Utrustning som är kopplad till skyddsjord via jordat 
vägguttag och/eller via annan utrustning och 
samtidigt är kopplad till kabel-TV nät kan i vissa fall 
medföra risk för brand.  
Főr att undvika detta skall vid anslutning av 
utrustningen till kabel-TV nät galvanisk isolator 
finnas mellan utrustningen och kabel-TV nätet.” 
 N/A 
Page of 73
Display