JBL SB 100 (serv.man3) EMC - CB Certificate ▷ View online
Page 65 of 68
Report No.: 350-120154AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
15.1.1
Replace the paragraph before NOTE 3 by the
following.
MAINS socket-outlets and interconnection
couplers mounted on CLASS I apparatus shall be
provided with protective earthing contacts which
are reliably connected to the PROTECTIVE
EARTHING TERMINAL or contact of the
apparatus. If not, it shall not permit connection of
CLASS I apparatus.
following.
MAINS socket-outlets and interconnection
couplers mounted on CLASS I apparatus shall be
provided with protective earthing contacts which
are reliably connected to the PROTECTIVE
EARTHING TERMINAL or contact of the
apparatus. If not, it shall not permit connection of
CLASS I apparatus.
N/A
15.1.1
Replace NOTE 4 by the following.
NOTE 4 Socket-outlets not allowing the
connection of CLASS I apparatus can be
designed, for instance, similar to IEC 60906-1,
standard sheets 3-1 or 3-2, or according to IEC
60320-2-2, standard sheets D or H.
NOTE 4 Socket-outlets not allowing the
connection of CLASS I apparatus can be
designed, for instance, similar to IEC 60906-1,
standard sheets 3-1 or 3-2, or according to IEC
60320-2-2, standard sheets D or H.
N/A
15.1.2
Delete the following sentence in NOTE.
An example of a connector not meeting the
requirements of this sub clause is the so-called
"banana" plug.
An example of a connector not meeting the
requirements of this sub clause is the so-called
"banana" plug.
N/A
15.1.3
Replace the references, “IEC 60083 [1], IEC
60320, IEC 60884, IEC 60906” by “JIS C 8282
(corresponding to IEC 60884), JIS C 8303, IEC
60320 and IEC 60906”.
60320, IEC 60884, IEC 60906” by “JIS C 8282
(corresponding to IEC 60884), JIS C 8303, IEC
60320 and IEC 60906”.
N/A
15.2
Add “and CLASS 0I EQUIPMENT” after the words,
“CLASS I EQUIPMENT”
“CLASS I EQUIPMENT”
N/A
15.2
Add the following paragraphs after the first
paragraph.
The external earth wire of plug with an external
earth wire shall not be earthed by a clip.
Rated voltage of plug with an protective external
earth wire shall be less 150 Vac.
paragraph.
The external earth wire of plug with an external
earth wire shall not be earthed by a clip.
Rated voltage of plug with an protective external
earth wire shall be less 150 Vac.
N/A
15.2
Delete the following paragraph.
In SUPPLY APPARATUS of CLASS I with non-
HAZARDOUS LIVE output voltage, output circuits
shall not be connected to the protective earthing
conductor.
In SUPPLY APPARATUS of CLASS I with non-
HAZARDOUS LIVE output voltage, output circuits
shall not be connected to the protective earthing
conductor.
N/A
15.3.1
In the first paragraph, replace IEC 60998-2-2 by
“IEC 60998-2-2 or JIS C 2814-2-2:2001”.
“IEC 60998-2-2 or JIS C 2814-2-2:2001”.
N/A
15.3.1
In the first paragraph, replace IEC 60999 by IEC
60999-1.
60999-1.
N/A
15.3.1
In the third paragraph, replace IEC 60335-1 by JIS
C 9335-1:2003 (corresponding to IEC 60335-1).
C 9335-1:2003 (corresponding to IEC 60335-1).
N/A
15.3.3
Replace “ISO 261 or ISO 262” by “JIS B 0205-
2:2001 or JIS B 0205-3:2001”.
2:2001 or JIS B 0205-3:2001”.
N/A
15.3.5
In the second paragraph, replace IEC 60950 by
JIS C 6950:2006.
JIS C 6950:2006.
N/A
Page 66 of 68
Report No.: 350-120154AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Replace Table 15 by the following.
RATED CURRENT
CONSUMPTION of the
apparatus
a
A
Nominal cross-sectional
area
mm
2
Up to and including 6
0.75 to 1
Over 6 up to and
including 10
including 10
1 to 1.5
Over 10 up to and
including 16
including 16
1.5 to 2.5
a
The RATED CURRENT CONSUMPTION
includes currents which can be drawn from
socket-outlets providing MAINS power for other
apparatus.
socket-outlets providing MAINS power for other
apparatus.
15.3.5
N/A
15.3.9
Add the following to the last of the first paragraph.
This does not apply to CLASS 0I EQUIPMENT
with a protective earthing terminal separately.
This does not apply to CLASS 0I EQUIPMENT
with a protective earthing terminal separately.
N/A
15.4.1
In NOTE 1, replace IEC 60884-1 by JIS C 8282
(corresponding to IEC 60884-1).
(corresponding to IEC 60884-1).
N/A
15.4.1
In NOTE 2, replace IEC 60083 [1] by JIS C 8303.
N/A
15.4.2
In NOTE, replace IEC 60083 [1] by JIS C
8303:1993 [1].
8303:1993 [1].
N/A
15.4.3
Add the following NOTE to Table 17.
NOTE If mains plug is parallel blade, a pull force
as given in “Over 10 A up to and including 16 A,
130/250 V” of Table 17 is applied.
NOTE If mains plug is parallel blade, a pull force
as given in “Over 10 A up to and including 16 A,
130/250 V” of Table 17 is applied.
N/A
16.1
Add the following to the last of first paragraph.
Or mains cords shall be of the sheathed type
complying with Appendix 1 of Article 1 of the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance..
Delete NOTE 1.
Replace the second paragraph by the following.
Compliance is checked by testing MAINS supply
flexible cords in accordance with JIS C 3662
(corresponding to IEC60227) or JIS C 3663
(corresponding to IEC 60245) or Appendix 1 of
Article 1 of the Ministerial Ordinance on stipulating
technical requirements for the Electrical Appliance.
Or mains cords shall be of the sheathed type
complying with Appendix 1 of Article 1 of the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance..
Delete NOTE 1.
Replace the second paragraph by the following.
Compliance is checked by testing MAINS supply
flexible cords in accordance with JIS C 3662
(corresponding to IEC60227) or JIS C 3663
(corresponding to IEC 60245) or Appendix 1 of
Article 1 of the Ministerial Ordinance on stipulating
technical requirements for the Electrical Appliance.
See appended table CL.14.
Pass
16.1
In this sub-clause, replace IEC 60227 by JIS C
3662 (corresponding to IEC 60227).
In this sub-clause, replace IEC 60245 by JIS C
3663 (corresponding to IEC 60245).
3662 (corresponding to IEC 60227).
In this sub-clause, replace IEC 60245 by JIS C
3663 (corresponding to IEC 60245).
N/A
Page 67 of 68
Report No.: 350-120154AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
16.1
Add the following paragraph after the third
paragraph.
An external earth wire of Class 0I equipment shall
be green/yellow, and the length of external earth
wire of plug with an external earth wire shall be
equal or more than 10 cm from the plug.
paragraph.
An external earth wire of Class 0I equipment shall
be green/yellow, and the length of external earth
wire of plug with an external earth wire shall be
equal or more than 10 cm from the plug.
N/A
16.2
Replace the first paragraph by the following.
Power supply cord conductors complied with JIS C
3662 (corresponding to IEC 60227) or JIS C 3663
(corresponding to IEC 60245) shall have a nominal
cross-sectional area not less than those shown in
table 18. If power supply cord conductors comply
with other standards, it shall comply with relevant
wiring requirements.
Power supply cord conductors complied with JIS C
3662 (corresponding to IEC 60227) or JIS C 3663
(corresponding to IEC 60245) shall have a nominal
cross-sectional area not less than those shown in
table 18. If power supply cord conductors comply
with other standards, it shall comply with relevant
wiring requirements.
See appended table CL.14.
Pass
Replace Table 18 by the following.
RATED CURRENT
CONSUMPTION of the
apparatus
a
A
Nominal cross-
sectional area
mm
2
up to and including 6
Over 6 up to and
including 10
Over 10 up to and
including 16
Over 6 up to and
including 10
Over 10 up to and
including 16
0,75
1
1,5
a
The RATED CURRENT CONSUMPTION
includes currents which can be drawn from the
socket-outlets providing MAINS power for other
apparatus.
socket-outlets providing MAINS power for other
apparatus.
16.2
See appended table CL.14.
Pass
16.3
In item a), replace IEC 60885-1 by JIS C 3661-
1:1998.
1:1998.
N/A
In item b), replace IEC 60227-2 by JIS C 3662-2
(corresponding to IEC 60227-2).
(corresponding to IEC 60227-2).
N/A
16.5
Add “or CLASS 0I EQUIPMENT used a plug with
an external earth wire” after the words, CLASS I
EQUIPMENT.
an external earth wire” after the words, CLASS I
EQUIPMENT.
N/A
20.1
In Note 3, replace each IEC 60065 and IEC 60707
by “JIS C 6065” and “JIS C 0066:2001 (IEC
60707).
by “JIS C 6065” and “JIS C 0066:2001 (IEC
60707).
N/A
Annex B
Replace normative by Informative.
N/A
Annex G
Replace IEC 60707 by JIS C 0066:2001
Replace IEC 60695-2-2 by JIS C 60695-2-2:2000.
Replace IEC 60695-11-10 by JIS Z 2391:1999.
Replace IEC 60695-2-2 by JIS C 60695-2-2:2000.
Replace IEC 60695-11-10 by JIS Z 2391:1999.
Pass
Annex N
Add “- protective earthing lead wire, protective
earthing contact of appliance inlet or external
protective earthing terminal in case of Class 0I
apparatus.” after the second dash of N.1.3.
earthing contact of appliance inlet or external
protective earthing terminal in case of Class 0I
apparatus.” after the second dash of N.1.3.
N/A
Page 68 of 68
Report No.: 350-120154AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Replace the first sentence and two dashes of
N.2.2, as follows:
The continuity of the protective earthing conecction
between
- the ACCESSIBLE conductive parts, including
TERMINALS regarded as ACCESSIBLE (see 8.4),
which should be connected to the PROTECTIVE
EARTHING TERMINAL, and
- the protective earthing contact of socket-outlets
respectively, if provided to deliver power to other
apparatus
should be checked between
- the protective earthing contact of the MAINS plug
or appliance inlet, or the PROTECTIVE
EARTHING TERMINAL in case of a
PERMANENTLY CONNECTED APPARATUS, for
CLASS I apparatus, and
- the protective earthing lead wire, the protective
earthing contact of appliance inlet, or external
protective earthing terminal, for CLASS 0I
apparatus.
N.2.2, as follows:
The continuity of the protective earthing conecction
between
- the ACCESSIBLE conductive parts, including
TERMINALS regarded as ACCESSIBLE (see 8.4),
which should be connected to the PROTECTIVE
EARTHING TERMINAL, and
- the protective earthing contact of socket-outlets
respectively, if provided to deliver power to other
apparatus
should be checked between
- the protective earthing contact of the MAINS plug
or appliance inlet, or the PROTECTIVE
EARTHING TERMINAL in case of a
PERMANENTLY CONNECTED APPARATUS, for
CLASS I apparatus, and
- the protective earthing lead wire, the protective
earthing contact of appliance inlet, or external
protective earthing terminal, for CLASS 0I
apparatus.
N/A
Click on the first or last page to see other SB 100 (serv.man3) service manuals if exist.