Page 65 of 68 
Report No.: 350-120154AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
15.1.1 
Replace the paragraph before NOTE 3 by the 
following. 
MAINS socket-outlets and interconnection 
couplers mounted on CLASS I apparatus shall be 
provided with protective earthing contacts which 
are reliably connected to the PROTECTIVE 
EARTHING TERMINAL or contact of the 
apparatus. If not, it shall not permit connection of 
CLASS I apparatus. 
 N/A 
15.1.1 
Replace NOTE 4 by the following. 
NOTE 4  Socket-outlets not allowing the 
connection of CLASS I apparatus can be 
designed, for instance, similar to IEC 60906-1, 
standard sheets 3-1 or 3-2, or according to IEC 
60320-2-2, standard sheets D or H. 
 N/A 
15.1.2 
Delete the following sentence in NOTE.  
An example of a connector not meeting the 
requirements of this sub clause is the so-called 
"banana" plug. 
 N/A 
15.1.3 
Replace the references, “IEC 60083 [1], IEC 
60320, IEC 60884, IEC 60906” by “JIS C 8282 
(corresponding to IEC 60884), JIS C 8303, IEC 
60320 and IEC 60906”. 
 N/A 
15.2 
Add “and CLASS 0I EQUIPMENT” after the words, 
“CLASS I EQUIPMENT” 
 N/A 
15.2 
Add the following paragraphs after the first 
paragraph. 
The external earth wire of plug with an external 
earth wire shall not be earthed by a clip. 
Rated voltage of plug with an protective external 
earth wire shall be less 150 Vac. 
 N/A 
15.2 
Delete the following paragraph. 
In SUPPLY APPARATUS of CLASS I with non-
HAZARDOUS LIVE output voltage, output circuits 
shall not be connected to the protective earthing 
conductor. 
 N/A 
15.3.1 
In the first paragraph, replace IEC 60998-2-2 by 
“IEC 60998-2-2 or JIS C 2814-2-2:2001”. 
 N/A 
15.3.1 
In the first paragraph, replace IEC 60999 by IEC 
60999-1. 
 N/A 
15.3.1 
In the third paragraph, replace IEC 60335-1 by JIS 
C 9335-1:2003 (corresponding to IEC 60335-1). 
 N/A 
15.3.3 
Replace “ISO 261 or ISO 262” by “JIS B 0205-
2:2001 or JIS B 0205-3:2001”. 
 N/A 
15.3.5 
In the second paragraph, replace IEC 60950 by 
JIS C 6950:2006. 
 N/A 
Page 66 of 68 
Report No.: 350-120154AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
Replace Table 15 by the following. 
 
 
 
 
RATED CURRENT 
CONSUMPTION of the 
apparatus 
a
 
Nominal cross-sectional 
area 
mm
2
 
 
Up to and including 6 
0.75 to 1 
 
Over 6 up to and 
including 10 
1     to  1.5 
 
Over 10 up to and 
including 16 
1.5  to  2.5 
 
 The RATED CURRENT CONSUMPTION 
includes currents which can be drawn from 
socket-outlets providing MAINS power for other 
apparatus. 
15.3.5 
 
 
 
 N/A 
15.3.9 
Add the following to the last of the first paragraph. 
This does not apply to CLASS 0I EQUIPMENT 
with a protective earthing terminal separately. 
 N/A 
15.4.1 
In NOTE 1, replace IEC 60884-1 by JIS C 8282 
(corresponding to IEC 60884-1). 
 N/A 
15.4.1 
In NOTE 2, replace IEC 60083 [1] by JIS C 8303. 
 
N/A 
15.4.2 
In NOTE, replace IEC 60083 [1] by JIS C 
8303:1993 [1]. 
 N/A 
15.4.3 
Add the following NOTE to Table 17. 
NOTE If mains plug is parallel blade, a pull force 
as given in  “Over 10 A up to and including 16 A, 
130/250 V” of Table 17 is applied. 
 N/A 
16.1 
Add the following to the last of first paragraph. 
Or mains cords shall be of the sheathed type 
complying with Appendix 1 of Article 1 of the 
Ministerial Ordinance on stipulating technical 
requirements for the Electrical Appliance..  
Delete NOTE 1. 
Replace the second paragraph by the following. 
Compliance is checked by testing MAINS supply 
flexible cords in accordance with JIS C 3662 
(corresponding to IEC60227) or JIS C 3663 
(corresponding to IEC 60245) or Appendix 1 of 
Article 1 of the Ministerial Ordinance on stipulating 
technical requirements for the Electrical Appliance.  
See appended table CL.14.
Pass 
16.1 
In this sub-clause, replace IEC 60227 by JIS C 
3662 (corresponding to IEC 60227). 
In this sub-clause, replace IEC 60245 by JIS C 
3663 (corresponding to IEC 60245). 
 N/A 
Page 67 of 68 
Report No.: 350-120154AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
16.1 
Add the following paragraph after the third 
paragraph. 
An external earth wire of Class 0I equipment shall 
be green/yellow, and the length of external earth 
wire of plug with an external earth wire shall be 
equal or more than 10 cm from the plug. 
 N/A 
16.2 
Replace the first paragraph by the following. 
Power supply cord conductors complied with JIS C 
3662 (corresponding to IEC 60227) or JIS C 3663 
(corresponding to IEC 60245) shall have a nominal 
cross-sectional area not less than those shown in 
table 18. If power supply cord conductors comply 
with other standards, it shall comply with relevant 
wiring requirements. 
See appended table CL.14.
Pass 
Replace Table 18 by the following. 
 
 
 
 
RATED CURRENT 
CONSUMPTION of the 
apparatus 
a
 
Nominal cross-
sectional area 
 
mm
2
 
 
up to and including 6 
Over 6 up to and 
including 10 
Over 10 up to and 
including 16 
0,75 
 
1,5 
 
a
 The RATED CURRENT CONSUMPTION 
includes currents which can be drawn from the 
socket-outlets providing MAINS power for other 
apparatus. 
16.2 
 
 
 
See appended table CL.14.
Pass 
16.3 
In item a), replace IEC 60885-1 by JIS C 3661-
1:1998. 
 N/A 
 
In item b), replace IEC 60227-2 by JIS C 3662-2 
(corresponding to IEC 60227-2). 
 N/A 
16.5 
Add “or CLASS 0I EQUIPMENT used a plug with 
an external earth wire” after the words, CLASS I 
EQUIPMENT. 
 N/A 
20.1 
In Note 3, replace each IEC 60065 and IEC 60707 
by “JIS C 6065” and “JIS C 0066:2001 (IEC 
60707). 
 N/A 
Annex B 
Replace normative by Informative. 
 
N/A 
Annex G 
Replace IEC 60707 by JIS C 0066:2001 
Replace IEC 60695-2-2 by JIS C 60695-2-2:2000.
Replace IEC 60695-11-10 by JIS Z 2391:1999. 
 Pass 
Annex N 
Add “- protective earthing lead wire, protective 
earthing contact of appliance inlet or external 
protective earthing terminal in case of Class 0I 
apparatus.” after the second dash of N.1.3. 
 N/A 
Page 68 of 68 
Report No.: 350-120154AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
Replace the first sentence and two dashes of 
N.2.2, as follows: 
The continuity of the protective earthing conecction 
between  
- the ACCESSIBLE conductive parts, including 
TERMINALS regarded as ACCESSIBLE (see 8.4), 
which should be connected to the PROTECTIVE 
EARTHING TERMINAL, and 
- the protective earthing contact of socket-outlets 
respectively, if provided to deliver power to other 
apparatus 
should be checked between 
- the protective earthing contact of the MAINS plug 
or appliance inlet, or the PROTECTIVE 
EARTHING TERMINAL in case of a 
PERMANENTLY CONNECTED APPARATUS, for 
CLASS I apparatus, and 
- the protective earthing lead wire, the protective 
earthing contact of appliance inlet, or external 
protective earthing terminal, for CLASS 0I 
apparatus. 
 N/A 
 
 