JBL SB 100 (serv.man3) EMC - CB Certificate ▷ View online
Page 57 of 68
Report No.: 350-120154AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
ATTACHMENT TO TEST REPORT IEC 60065
MALAYSIA NATIONAL DIFFERENCES
Audio, Video and similar apparatus
Differences according to ...............:
IEC 60065
Attachment Form No......................:
MY_ND_IEC60065A
Attachment Originator ...................:
SIRIM QAS International Sdn. Bhd.
Master Attachment .........................:
2008-05
Copyright © 2008 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
(IECEE), Geneva, Switzerland. All rights reserved.
No.
Requirement - Test
Result - Remark
Verdict
Special
Requirements
-
1.
Appliance shall be subjected to test under tropical
conditions as specified in the related standards
conditions as specified in the related standards
Considered. Pass
2.
Appliance shall be marked with rated voltage 240 V
or voltage range incorporating 240V
Marking at 220V or 230V only is not allowed
or voltage range incorporating 240V
Marking at 220V or 230V only is not allowed
100-240V Pass
3.
Mains frequency is 50Hz
50/60Hz
Pass
4.
Tests shall be conducted at 240V
Pass
5.
Tests shall be conducted at 25 ± 5 ºC, unless
otherwise specified in the standards
otherwise specified in the standards
Pass
6.
The rated power input shall be the corresponding
value measured at 240 V, 50 Hz
value measured at 240 V, 50 Hz
Pass
7.
Appliances shall use the following plug:
Pass
a) 13A fused plugs complying to MS 589 or
BS1363 OR
BS1363 OR
See appended Table CL.14.
Pass
b) 2.5A, 250V, flat non rewireable two pole plugs
with cord for connection of class II equipment
complying to MS 1578 or BS EN 50075 OR
with cord for connection of class II equipment
complying to MS 1578 or BS EN 50075 OR
See appended Table CL.14.
Pass
c) 15A, plugs complying to MS 1577
N/A
8.
Class 0 and 01 are not allowed
Class II equipment.
Pass
9.
The supply cords shall comply to MS 140 or BS
6500 or IEC 60227-5 (PVC insulated cords) or IEC
60245-4 (Rubber insulated cords)
6500 or IEC 60227-5 (PVC insulated cords) or IEC
60245-4 (Rubber insulated cords)
Pass
10.
Standard colour code of supply cables: "Brown"
for Live, "Blue" for Neutral, “Green” or
"combination of Green &Yellow" for Earth
for Live, "Blue" for Neutral, “Green” or
"combination of Green &Yellow" for Earth
Pass
11.
Instruction manual shall be in Malay Language
and /or English
and /or English
English. Pass
Specific Requirements to IEC 60065
-
5 MARKING
5.1
Identification and supply ratings
Pass
Page 58 of 68
Report No.: 350-120154AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Rated current or power consumption .....................:
Pass
Measured consumption at 240 V, 50Hz not
exceeding the marked value by more than 10%
exceeding the marked value by more than 10%
Pass
7
HEATING UNDER NORMAL CONDITIONS
7.1
Temperature rises not exceeding specified values
(Table 3 – Normal Conditions)
For tropical climates; permissible temperatures
shall be reduced with 10K
The values of the temperature rises are based on a
maximum ambient temperature of 45
(Table 3 – Normal Conditions)
For tropical climates; permissible temperatures
shall be reduced with 10K
The values of the temperature rises are based on a
maximum ambient temperature of 45
°C for tropical
climates
Pass
10 INSULATION
REQUIREMENTS
10.2 Humidity
treatment
For tropical conditions; 120 hours, 90-95% RH,
40
40
±2°C
Pass
10.3
Insulation resistance and dielectric strength
Pass
11 FAULT
CONDITIONS
11.2
Heating under fault conditions
Temperature rises not exceeding specified values
(Table 3 – Fault conditions)
For tropical climates; permissible temperatures
shall be reduced with 10K
Temperature rises not exceeding specified values
(Table 3 – Fault conditions)
For tropical climates; permissible temperatures
shall be reduced with 10K
Pass
-
Ukrainian deviation for 6th ED (GOST 12.2.006-87, 2007-05-29)
-
1.
"National difference" in testing of conformity with the
requirements of IEC 60335 series standards is the
value of the nominal voltage that is fixed 220V а.с.
for the power supply network in Ukraine and is used
for testing instead of the value specified bу the
manufacturer.
requirements of IEC 60335 series standards is the
value of the nominal voltage that is fixed 220V а.с.
for the power supply network in Ukraine and is used
for testing instead of the value specified bу the
manufacturer.
N/A
Page 59 of 68
Report No.: 350-120154AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
National Differences – Japan, J60065 (H23)
1.1.3
Add the following as a NOTE after the first sentence.
NOTE 1 In Japan, the requirements for regions
with moderate apply.
with moderate apply.
Pass
2.4.9
In NOTE 1, replace “see 4.2.2 of IEC 62151” by
“see 4.2.2 of IEC 62151 [27]”.
“see 4.2.2 of IEC 62151 [27]”.
N/A
2.6.2A
Add this sub clause.
CLASS 0I EQUIPMENT: Equipment which has, as
for protection against electric shock,
for protection against electric shock,
- at least using BASIC INSULATION, and
- providing a means of connecting to the
protective earthing conductor in the building wiring
those conductive parts that are otherwise capable
of assuming HAZARDOUS VOLTAGES if the
BASIC INSULATION fails, and
protective earthing conductor in the building wiring
those conductive parts that are otherwise capable
of assuming HAZARDOUS VOLTAGES if the
BASIC INSULATION fails, and
- using a supply cord without earthing conductor
or a plug without earthing pin.
Apparatus provided with a cord set having a two-
pin type plug with a lead wire for earthing or having
three pin - tow pin adaptor is also regarded as
Class 0I.
NOTE Class 0I equipment may have a part
constructed with Double Insulation or Reinforced
Insulation.
or a plug without earthing pin.
Apparatus provided with a cord set having a two-
pin type plug with a lead wire for earthing or having
three pin - tow pin adaptor is also regarded as
Class 0I.
NOTE Class 0I equipment may have a part
constructed with Double Insulation or Reinforced
Insulation.
N/A
3.2
Add the “Class 0I equipment” in the first sentence of
this sub-clause.
this sub-clause.
N/A
3.2
Add the following after the first sentence of this
sub-clause.
NOTE Equipment often transported and used
should not be Class I equipment nor Class 0I
equipment.
sub-clause.
NOTE Equipment often transported and used
should not be Class I equipment nor Class 0I
equipment.
N/A
4.2.8
Delete this clause.
N/A
4.3.4, b)
Replace IEC 60730-1 by JIS C 9730-1
(corresponding to IEC 60730-1).
(corresponding to IEC 60730-1).
N/A
4.3.12
Delete this clause.
N/A
4.3.13
Replace “250 V a.c.” by “the maximum of the
variable range”.
variable range”.
N/A
Page 60 of 68
Report No.: 350-120154AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
National Differences – Japan, J60065 (H23)
5.4.2A
For CLASS 0I EQUIPMENT, the following
instruction shall be indicated where readily visible
on the mains plug or the product:
“WARNING: Provide an earthing connection”
Example in Japanese:
instruction shall be indicated where readily visible
on the mains plug or the product:
“WARNING: Provide an earthing connection”
Example in Japanese:
Moreover, for CLASS 0I EQUIPMENT, the
following instruction shall be indicated where
readily visible on the product or written in the
operating instructions:
“WARNING: Provide an earthing connection
before the mains plug is connected to the mains.
And, when disconnecting the earthing connection,
be sure to disconnect after pulling out the mains
plug from the mains.”
Example in Japanese:
N/A
6.2
In NOTE 1, replace IEC 61040 [10] by JIS C
6181:1995 [10].
6181:1995 [10].
N/A
7.1.5
Add the words, “without dimensions restrictions”
after the figure, “65 K” in the first sentence of
Condition “b” in Table 3 as follows.
For parts not likely to be touched during intended
use, temperature rises up to 65 K without
dimensions restrictions are allowed under normal
operating conditions.
after the figure, “65 K” in the first sentence of
Condition “b” in Table 3 as follows.
For parts not likely to be touched during intended
use, temperature rises up to 65 K without
dimensions restrictions are allowed under normal
operating conditions.
N/A