Page 61 of 68 
Report No.: 350-120154AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
National Differences – Japan,  J60065 (H23) 
7.1.5 
Add the following paragraph as 2
nd
paragraph of 
Condition “d “in Table 3. 
For materials which are not listed in Table 3, 
temperature rises in the normal operating 
conditions are considered satisfactory if these 
materials comply with item 3 of detailed 
regulations, 1.(1),b, Appendix 4 in the Ministerial 
Ordinance on stipulating technical requirements for 
the Electrical Appliance and Material. Permissible 
temperature rise of “Supply cords and wiring 
insulation” is applicable only to the materials used 
in supply cords complying with JIS C 3662 
(corresponding to IEC 60227) or JIS C 3663 
(corresponding to IEC 60245). Materials used in 
other wiring shall comply with item 3 of detailed 
regulations, 1.(1).b, Appendix 4 in the Ministerial 
Ordinance on stipulating technical requirements for 
the Electrical Appliance and Material. 
 Pass 
7.1.5 
In the first paragraph of Condition “f” of Table 3, 
add ”JIS K 7206:1999 or” before the reference, 
ISO 306. 
 Pass 
7.1.5 
In Condition “f,” 1) of Table 3, add ”JIS K 
7206:1999 or” before the reference, ISO 306. 
 Pass 
7.2 
In NOTE 2, add “or JIS standard (identical to or 
modified IEC)” after the word, IEC standard. 
 N/A 
8.5 
In the first paragraph, add “and Class 0I 
Equipment” after the words, Class I Equipment. 
 N/A 
8.5 
In the six paragraph (before NOTE 3), add the 
following to the end of the first sentence. 
CLASS 0I EQUIPMENT shall be provided with a 
protective earthing terminal at any point outside 
the apparatus where easily visible or a protective 
external earth wire from mains plug. 
 N/A 
8.11 
In NOTE 2, c), add “or JIS C 2107, JIS C 2336, JIS 
C 2338” after the reference, IEC 60454. 
 N/A 
9.1.1.1 
In the last paragraph, add the following sentence 
after the first sentence. 
For CLASS 0I EQUIPMENT, the r.m.s. TOUCH-
CURRENT to earth shall not be more than 1.0 mA.
 N/A 
10 
In NOTE, replace “IEC 60664-1 and IEC 60664-4 
[9]” by “JIS C 0664:2003 and IEC/TR3 60664-4 [8]”
 Pass 
10.1 
Add “CLASS 0I EQUIPMENT and” to the head of 
the first paragraph. 
 N/A 
Page 62 of 68 
Report No.: 350-120154AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
In Table 5, add the following values to the sub-
table of NOTE. 
 
Test voltage (peak)  
 Operating 
Voltage 
(peak) 
Curve A Curve B  
 
142 V 
1 414 V
2 828 V  
10.3.2 
 
See appended table 
CL.10.3. 
Pass 
11.2.1 
Add the following after the original NOTE. 
NOTE 2  Fuses except for the ones according to 
IEC 60127 shall be tested in consideration of the 
characteristic. 
See appended table 
CL.11.2. 
Pass 
11.2.3 
Add “and CLASS 0I” after the words, CLASS I. 
 
N/A 
13.4 
In NOTE 2 of Table 11, replace IEC 60664-1 by 
JIS C 0664:2003 (corresponding to IEC 60664-1). 
See appended table 
CL.11.2. 
Pass 
14.3.3.2 
In the second sentence of the first paragraph, add 
“or JIS C 2107, JIS C 2336 and JIS C 2338” after 
the reference, IEC 60454. 
 N/A 
14.5.1.1 
In item a), add “JIS C 9730 series or” before the 
reference, IEC 60730 series. 
 N/A 
14.5.1.2 
In the first sentence of item a), replace “IEC 
60691” by “IEC 60691, JIS C 6691:2003 or 
Appendix 3 of the Ministerial Ordinance on 
stipulating technical requirements for the Electrical 
Appliance and Material”. 
 N/A 
14.5.1.2 
After the second sentence of item a), replace “IEC 
60691” by “JIS C 6691:2003 or IEC 60691”. 
 N/A 
14.5.2.1 
Replace the first and the second sentence as 
follows: 
Fuse-links, DIRECTLY CONNECTED TO THE 
MAINS, used in order to prevent the apparatus 
from becoming unsafe within the sense of this 
standard shall comply with 
- the relevant part of IEC 60127 or JIS C 6575, 
unless they have a rated current outside the range 
specified in that standard. In the latter case, they 
shall comply with the relevant part of IEC 60127 or 
JIS C 6575 as far as applicable, or 
- Appendix 3 of the Ministerial Ordinance on 
stipulating technical requirements for the Electrical 
Appliance and Material (limited to Fuses with the 
rated current of 1 A or more). 
See appended table CL.14.
Pass 
Page 63 of 68 
Report No.: 350-120154AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
14.5.2.2 
Add the following sentence before the last 
paragraph. 
For Fuses according to Appendix 3 of the 
Ministerial Ordinance on stipulating technical 
requirements for the Electrical Appliance and 
Material, all that needs to be marked is the rated 
current. 
 N/A 
14.5.3 
Replace IEC 60730-1 by JIS C 9730-1 
(corresponding to IEC 60730-1). 
 N/A 
14.5.4 
Replace IEC 60127 by “IEC 60127 or JIS C 6575”.  
N/A 
14.6.1 
Add the following paragraph after NOTE. 
The following manually operated mechanical 
switches shall meet the requirements specified in 
item a) or b) below. 
-  the controlling current exceeds 0.2 A r.m.s a.c. 
or d.c. 
-  the voltage across the open switch contacts 
exceeds 35 Vpeak ac or 24 Vdc.   
 N/A 
14.6.1 
 
 
In item a), replace IEC 61058-1 by “IEC 61058-1 or 
JIS C 4526-1:1999”. 
 N/A 
14.6.2 
In item a), replace IEC 61058-1 by “IEC 61058-1 or 
JIS C 4526-1:1999”. 
 N/A 
14.6.3 
In item a), replace IEC 61058-1 by “IEC 61058-1 or 
JIS C 4526-1:1999”. 
 N/A 
14.6.5 
In item a), replace IEC 61058-1 by “IEC 61058-1 or 
JIS C 4526-1:1999”. 
 N/A 
14.7 
Replace IEC 60950 by JIS C 6950:2006. 
 
N/A 
Page 64 of 68 
Report No.: 350-120154AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
15.1.1 
Replace the first and second paragraph by the 
following. 
Plugs and appliance couplers for the connection of 
the apparatus to the MAINS and socket-outlets 
and interconnection couplers for providing MAINS 
power to other apparatus shall comply with the 
relevant JIS standards for plugs, socket-outlets, 
appliance couplers or interconnection couplers. If 
there is no appropriate JIS standard, they shall 
comply with the relevant IEC standards. 
Appliance connectors, interconnection outlets and 
interconnection plug-connectors compiled with 
Appendix 3 of the Ministerial Ordinance on 
stipulating technical requirements for the Electrical 
Appliance and Material are accepted. In that case, 
if due to the shape the contact parts are 
connectable to those specified in standard sheets 
of IEC 60320-1, they shall comply with dimensions 
and ratings specified in the relevant standard 
sheets of IEC 60320-1. 
Examples of relevant specifications and standards:
- Plugs / Socket-outlets: Appendix 4 of Article 1 of 
the Ministerial Ordinance on stipulating technical 
requirements for the Electrical Appliance. Article 
2 (corresponding to IEC 60884) of the 
Ordinance. 
-  Appliance couplers: Appendix 4 of Article 1 of 
the Ministerial Ordinance on stipulating technical 
requirements for the Electrical Appliance. Article 
2 (corresponding to IEC 60320-1) of the 
Ordinance. 
-  Appliance inlets: IEC 60320-1 
- Interconnection outlets: Appendix 4 of Article 1 of 
the Ministerial Ordinance on stipulating technical 
requirements for the Electrical Appliance. IEC 
60320-2-2.  
- Interconnection couplers: Appendix 4 of Article 1 
of the Ministerial Ordinance on stipulating 
technical requirements for the Electrical 
Appliance.  
Delete NOTE 1 and NOTE 2. 
See appended table CL.14.
Pass 
15.1.1 
Replace the paragraph after NOTE 2 by the 
following. 
MAINS socket-outlets and interconnection 
couplers mounted on CLASS 0I and CLASS II 
apparatus shall not permit connection of CLASS I 
apparatus. 
 N/A 
Page of 77