Report No.: 350-120154AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
J.2
NO: After Table J.1 the following is added:
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
N/A
ZC
ANNEX ZC TO EN 60065, A-DEVIATIONS (EN)
-
5.1
IT: Additional markings on the outside of the TV
receiver in Italian language
receiver in Italian language
N/A
IT:User instructions in Italian language including a
conformity declaration
conformity declaration
N/A
IT: Certification number on the back cover
N/A
6.1
N/A
14
SE: Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
Justification: Ordinance (1990:944) on Prohibition
in Connection with handling. Importation and
exportation of Chemical Products (Certain Cases)
thermostats, relays and level controllers are not
allowed.
Justification: Ordinance (1990:944) on Prohibition
in Connection with handling. Importation and
exportation of Chemical Products (Certain Cases)
N/A
Page 54 of 68
Report No.: 350-120154AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
ZZ
Australian Deviation (CB Bulletin data base April 26, 2010)
-
7.15
Alternative to the method described in footnote f)
N/A
7.2
Alternative to the method described in footnote h)
N/A
15.1.1
Plugs for the connection of apparatus to mains-
powered socket-outlets shall comply with AS/NZS
3112 or AS/NZS 3123.
powered socket-outlets shall comply with AS/NZS
3112 or AS/NZS 3123.
See appended table CL.14.
Pass
15.3.5
In Table 15, in the second and third rows of the first
column replace ‘6’ with ‘7.5’
column replace ‘6’ with ‘7.5’
Detachable supply cord.
N/A
16.2
In Table 18, in the second and third rows of the first
column replace ‘6’ with ‘7.5’.
column replace ‘6’ with ‘7.5’.
Pass
16.3
A flexible cord complying with AS/NZS 3191 need
not undergo this test.
not undergo this test.
N/A
20.1.4
In Table 21, in the third and fourth columns change
both ‘HB75’ and ‘No requirement’ to ‘V-1’.
both ‘HB75’ and ‘No requirement’ to ‘V-1’.
Pass
20.201
Resistance to fire - Alternative tests
N/A
20.201.1
General – “Parts of non-metalic material”
N/A
a) Exemption for components contained in an
enclosure of material V-0 to AS/NZS 60695.11.10
with openings not exceeding 1 mm in width
enclosure of material V-0 to AS/NZS 60695.11.10
with openings not exceeding 1 mm in width
No PIS
N/A
b) Exemption for small components as defined in
20.201.1
20.201.1
N/A
20.201.2 Tests
N/A
20.201.2.1 Testing of non-metalic parts
N/A
Part of non-metallic material shall be subject to the
glow-wire test of AS/NZS 60695.2.11
which shall be carried out at 550°C.
glow-wire test of AS/NZS 60695.2.11
which shall be carried out at 550°C.
N/A
20.201.2.2 Testing of insulated parts
N/A
Part of insulating material supporting
POTENTIAL
IGNITION SOURCES
shall be subject to the glow wire
test of AS/NZS 60695.2.11 which shall be carried
out at 750°C.
The test shall be also carried out on other parts of
insulating material which are within a
distance of 3 mm of the connection.
out at 750°C.
The test shall be also carried out on other parts of
insulating material which are within a
distance of 3 mm of the connection.
N/A
For parts which withstand the glow-wire test but
produce a flame, other parts above the
connection within the envelope of a vertical cylinder
having a diameter of 20 mm and a height of 50 mm
shall be subjected to the needle-flame test.
However, parts shielded by a barrier
which meets the needle-flame test need not be
tested.
The needle-flame test shall be made in accordance
with AS/NZS 4695.2.2 with the following
modifications: Clause of AS/NZS 4695.2.2
(“5/Severities”, “8/Test procedure”,
“10/Evaluation of test results”)
produce a flame, other parts above the
connection within the envelope of a vertical cylinder
having a diameter of 20 mm and a height of 50 mm
shall be subjected to the needle-flame test.
However, parts shielded by a barrier
which meets the needle-flame test need not be
tested.
The needle-flame test shall be made in accordance
with AS/NZS 4695.2.2 with the following
modifications: Clause of AS/NZS 4695.2.2
(“5/Severities”, “8/Test procedure”,
“10/Evaluation of test results”)
N/A
Page 55 of 68
Report No.: 350-120154AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
The needle-flame test shall not be carried out on
parts of material classified as V-0 or V-1
according to AS/NZS 60695.11.10 provided that
the sample tested was not thicker than the
relevant part.
parts of material classified as V-0 or V-1
according to AS/NZS 60695.11.10 provided that
the sample tested was not thicker than the
relevant part.
N/A
20.201.2.3 Testting by needle-flame test
N/A
If parts, other than enclosures, do not withstand the
glow wire tests of 20.201.2.2, by failure to
extinguish within 30 s after the removal of the glow-
wire tip, the needle-flame test detailed in
20.201.2.2 shall be made on all parts of non-
metallic material which are within a distance of
50 mm or which are likely to be impinged upon by
flame during the tests of 20.201.2.2.
glow wire tests of 20.201.2.2, by failure to
extinguish within 30 s after the removal of the glow-
wire tip, the needle-flame test detailed in
20.201.2.2 shall be made on all parts of non-
metallic material which are within a distance of
50 mm or which are likely to be impinged upon by
flame during the tests of 20.201.2.2.
N/A
20.201.2.4 Testing of printed boards
N/A
Material of printed circuit boards on which the
available power exceeds 15 VA at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets V-
1 or better to AS/NZS 60695.11.10, unless used in a
fire enclosure
available power exceeds 15 VA at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets V-
1 or better to AS/NZS 60695.11.10, unless used in a
fire enclosure
N/A
Material of printed circuit boards on which the
available power exceeds 15 VA at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to AS/NZS
60695.11.10
available power exceeds 15 VA at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to AS/NZS
60695.11.10
N/A
21.201.3
For open circuit voltages greater than 4kV
N/A
Potential
ignition
sources
with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
enclosure to V-1
N/A
ANNEX B Apparatus to be connected to the
TELECOMMUNICATION NETWORKS
For Australia only, this Annex is replaced by the
requirements of the Telecommunications
Labelling Notice issued under the
Telecommunications Act.
For Australia only, this Annex is replaced by the
requirements of the Telecommunications
Labelling Notice issued under the
Telecommunications Act.
Not connected to
telecommunication network
telecommunication network
N/A
Page 56 of 68
Report No.: 350-120154AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
ZZ.2
Australian differences (Amend. No.1 to AS/NZS 60065:2003)
-
19.201
Additional stability requirements for television
receivers
(This clause forms part of the Standard 12
months from 31 January, 2008)
receivers
(This clause forms part of the Standard 12
months from 31 January, 2008)
N/A
19.201.1
Warning notice in instructions
N/A
Warning notice on the apparatus
N/A
19.201.2 Restraining
device
(This clause forms part of the Standard 18
months from 31 January, 2008)
months from 31 January, 2008)
N/A
19.201.2.1 Television receiver is provided with a restraining
device
N/A
19.201.2.2 Information and capable of withstanding a pull of
100N
N/A
Label on the product
N/A
19.201.3 Glass
slide
test
(This clause forms part of the Standard 5 years
from 31 January, 2008)
from 31 January, 2008)
N/A
-
Korea Deviation (CB Bulletin, May 31, 2012)
-
5.101
Other Marking: Wording
or an information
regulated in IEC Publication 417 giving high voltage
warning to layman shall be marked, if an apparatus
contains a part more than 600 volts.
warning to layman shall be marked, if an apparatus
contains a part more than 600 volts.
N/A
15.1.1
Plugs for the connection of the apparatus to the
supply mains and socket outlets for providing mains
power to other apparatus shall comply with the
Korean requirement (KSC8300 and 8305)
power to other apparatus shall comply with the
Korean requirement (KSC8300 and 8305)
Shall be evaluated when
submitted for national
approval.
submitted for national
approval.
N/A
31.
Radio frequency interference
The apparatus shall comply with the relevant
The apparatus shall comply with the relevant
CISPR requirements (EMC=EMI+EMS)
Note: The measurement of
radio frequency interference is
not covered in this test report.
radio frequency interference is
not covered in this test report.
N/A